KOREASCHOLAR

전기다리미의 발화원인 판정에 관한 현상학적 고찰 A Phenomenological Review on the Decision on the Cause of Ignition of Electric Iron

문용수, 공하성, 이종화
  • 언어KOR
  • URLhttp://db.koreascholar.com/Article/Detail/245637
대한안전경영과학회지
제11권 제1호 (2009.03)
pp.43-49
대한안전경영과학회 (Korea Safety Management & Science)
초록

This study set three kinds of situation and observed the various states such as carbonization by experimenting damages by fire of electric iron. The results of this study are as follows: The fire did not occurred when the unpowered iron over mattress and cotton shirts was com busted completely by external flame because the temperature of surface of soleplate and mattress did not reach the minimum ignition energy and when the powered electric iron over mattress and cotton shirts was left for an hour with its temperature dial set to high because the temperature of combustibles did not reach the minimum ignition energy. The fire occurred when the electric iron in which the outer box, bi-metal switch, and temperature fuse were removed over mattress and cotton shirts was powered by through heater terminal, and then the electric iron, mattress, and cotton shirts were combusted by the fallen combustibles because the temperature of combustibles reached to the minimum ignition energy with the help of active transfer of heat.

저자
  • 문용수 | Mun, Yong-Soo
  • 공하성 | Kong, Ha-Sung
  • 이종화 | Lee, Jong-Hwa