KOREASCHOLAR

xEV용 배터리 모듈의 냉각유체 유입구 위치에 따른 냉각성능 분석 Analysis of Cooling Performance of xEV Battery Module Depending on Cooling Fluid Inlet Position

류의환, 김선우, 김우태
  • 언어KOR
  • URLhttp://db.koreascholar.com/Article/Detail/291763
한국기계기술학회지 (韓國機械技術學會誌)
제15권 제6호 (2013.12)
pp.967-971
한국기계기술학회 (Korean Society of Mechanical Technology)
초록

A three dimensional numerical analysis was performed to study the cooling performance of xEV battery module depending on cooling fluid inlet position. Depending on the inlet position from the top, case 1 (top inlet), case 2 (middle inlet), and case 3 (bottom inlet) are selected. For the case 1, the temperature of the battery near inlet was higher than that of the battery near outlet. For the case 2 and 3 the temperature of the battery near inlet was lower than that of the battery near outlet. From the analysis result, the cooling performance is higher in the order of case 2, case 3, and case 1.

목차
Abstract
 1. 서론
 2. 연구 방법
  2.1 해석 모델
  2.2 계산 조건
  2.3 지배 방정식
 3. 결과 및 토의
 4. 결론
 후기
 References
저자
  • 류의환(공주대학교 대학원 기계공학과) | Eui Hwan Ryu
  • 김선우(공주대학교 대학원 기계공학과) | Sun Woo Kim
  • 김우태(공주대학교 기계자동차공학부) | Woo Tae Kim Corresponding Author