KOREASCHOLAR

히트펌프를 이용한 계사 냉난방 공조 및 음용수 급수 병행시스템 최적 설계

백이, 강금춘, 문종필, 이태석, 권진경
  • 언어KOR
  • URLhttp://db.koreascholar.com/Article/Detail/311698
한국기계기술학회지 (韓國機械技術學會誌)
제18권 제1호 (2016.02)
pp.141-147
한국기계기술학회 (Korean Society of Mechanical Technology)
초록

The aim of these studies are to provide a basic data for the development of high-efficiency environmental improvement system that can parallel the cage(henhouse) and hot and cold potable water supply for increased summer heat stress relief and winter feed efficiency by optimal design. The cage area is 273m2. The air-to-water heat pump with 20RT capacity was used for heating and cooling. The control was used as an electric hot water boiler. For calculating heating load determined the cage size, materials, heat pump capacity, heating capacity, heat storage tank, and drinking water tank capacity etc. Therefore the capacity of heat pump was set-up using 20RT. The cage was built as a prefabricated panels henhouse of 13×21×4.5 m (width×depth×height). The heat storage tank and was drinking water tank capacity was constructed 3tons and 10 tons, respectively. In future, it is thought that optimal design considering the cage size and hen breeding scale is required.

저자
  • 백이(Member, National Institude of Agricultural Science, RDA) | Y. Paek Corresponding Author
  • 강금춘(National Institude of Agricultural Science, RDA) | G. C. Kang
  • 문종필(National Institude of Agricultural Science, RDA) | J. P. Moon
  • 이태석(National Institude of Agricultural Science, RDA) | T. S. Lee
  • 권진경(National Institute of Horticultural and Herba Science, RDA) | J. K. Kwon