KOREASCHOLAR

폐기물 소각시설 내부 소음에 관한 연구 A Study on Noise in Waste Facilities

서병석, 박노국, 전용한
  • 언어KOR
  • URLhttp://db.koreascholar.com/Article/Detail/395273
대한안전경영과학회지
제22권 제2호 (2020.06)
pp.15-22
대한안전경영과학회 (Korea Safety Management & Science)
초록

Industrial facilities need design to predict and reduce noise from design to prevent and reduce noise. The purpose of this study is to predict worker's environment and evaluate safety by analyzing noise inside underground blower room and air compressor room with fluid machinery in waste facility. This waste incineration facility was analyzed based on the ground floor, ground floor blower chamber, and air compressor chamber. The results of SPL(Sound Pressure Level) analysis at 1.5m away, which are frequently used to measure the SPL as a noise source, are as follows. SPL of basement level: 46.80[dB], SPL of ground layer: 48.57[dB]. As a result, it was expected that the noise level would be considerably lower than the 8 hours 50[dB] noise exposure per day.

목차
Abstract
1. 서 론
2. 연구방법
3. 판정기준
4. 분석결과
    4.1 송풍기실 사업장 내부 소음해석
    4.2 공기 압축기실 및 송풍기실 내부 소음해석
5. 결 론
6. References
저자
  • 서병석(상지대학교 정보보안학과) | Byung-Suk Seo (Dept. of Information Security, Sangji University)
  • 박노국(상지대학교 경영정보학과) | Ro-Gook Park (Dept. of Management Information, Sangji University)
  • 전용한(상지대학교 소방공학과) | Yong-Han Jeon (Dept. of Fire Protection Engineering, Sangji University) Corresponding Author