KOREASCHOLAR

7㎿급 중속 4행정 원전 비상디젤발전기 저속기동 적용 이후 연소실 성능에 미치는 영향에 관한 연구 A Study on the Effect on Combustion Chamber Performance After the Slow Start Application of 7㎿ Medium Speed 4 Stroke Emergency Diesel Generator for NPP

강승희, 김명훈
  • 언어KOR
  • URLhttp://db.koreascholar.com/Article/Detail/402097
한국기계기술학회지 (韓國機械技術學會誌)
제22권 제5호 (2020.10)
pp.931-936
한국기계기술학회 (Korean Society of Mechanical Technology)
초록

In the past, the U.S. NRC(Nuclear Regulatory Commission) strictly required testing of the EDG for NPP through Reg.Guide 1.108 Rev 1. However, these test requirements acted as a deterioration and wear factor for diesel engines, and are now applying Reg.Guide 1.9 Rev 3, which relaxed regulatory requirements and improved performance monitoring. After applying the new regulatory guidelines in this study, the EDG analyzed the performance of the combustion chamber. As a result, there were no signs of deterioration or decreased performance of the current EDG. This is due to slow start, short operation time, the use of high quality fuel oil and proper maintenance. On the other hand, if the performance is proven, it is judged that proper period extension of cylinder maintenance is possible.

목차
ABSTRACT
1. 서 론
2. 실험설비 및 연구 방법
    2.1 분석 장비
    2.2 대상설비
    2.3 진단방법
    2.4 엔진 성능 평가
    2.5 사용연료유
3. 성능분석 결과
    3.1 EDG 열성능 관련 운전변수 추이분석
    3.2 엔진 상태진단 결과
4. 결 론
References
저자
  • 강승희(한국수력원자력 중앙연구원 기계연구소) | Seung-Hee Kang 교신