KOREASCHOLAR

장기간 고온에 노출된 방사관의 열응력 및 열변형에 관한 유한요소법 해석 Finite Element Method of Thermal Stress and Deformation of Radiant Tube Under High Temperature

최락준, 김필, 김량균, 김설하
  • 언어KOR
  • URLhttp://db.koreascholar.com/Article/Detail/425698
한국기계기술학회지 (韓國機械技術學會誌)
제25권 제4호 (2023.08)
pp.534-540
한국기계기술학회 (Korean Society of Mechanical Technology)
초록

Radiant tubes heat exchangers are critical components that facilitate the heat transfer process to steel in an annealing furnace, and it addresses several engineering problems, such as thermal stress and mechanical failure due to long-term thermal cycling, which can significantly affect the longevity of the tubes and maintenance requirements. In this study, we used commercial software (ANSYS) to simulate the thermal stress and deformation of radiant tubes subjected to extreme thermal conditions and pressure loads. We evaluated both thermally induced deformation and creep deformation, which is a time-dependent deformation under constant stress over the long term. The results showed that uneven temperature conditions and pressure loads lead to significant deformation and potential failures. To mitigate these engineering challenges, we also tested several designs that include supporting brackets. This study provides valuable insights for designing radiant tube heat exchangers in annealing furnaces to extend their lifespan and ensure system safety.

저자
  • 최락준(경북대학교상주캠퍼스) | Rak Jun Choi
  • 김필(부산대학교 기계공학과) | Phil Kim
  • 김량균(포항산업과학연구원) | Ryang-Gyoon Kim
  • 김설하(경북다핵교 정밀기계공학과) | Seol-Ha Kim