KOREASCHOLAR

자동차용 수소 차단밸브의 유동 특성에 대한 수치해석 Numerical Analysis of Flow Characteristics of Hydrogen Shut-off Valve for Automotive Vehicles

김나용, 김문학, 이치우
  • 언어KOR
  • URLhttp://db.koreascholar.com/Article/Detail/429408
한국기계기술학회지 (韓國機械技術學會誌)
제25권 제6호 (2023.12)
pp.1128-1133
한국기계기술학회 (Korean Society of Mechanical Technology)
초록

In this study, a numerical analysis study was conducted on the flow characteristics according to the internal flow path change and differential pressure of the hydrogen shut-off valve, and through this, the pressure loss characteristics and flow coefficient of the hydrogen shut-off valve were predicted. ANSYS CFX program was used to predict the flow characteristics of the hydrogen shut-off valve. When the flow path gap was 1.3 mm, the design conditions of the hydrogen shut-off valve were satisfied, and the value of the flow coefficient of the valve was about 1.53. As the inlet pressure of the hydrogen shut-off valve increases, the outlet flow rate increases, but regardless of the inlet pressure, the flow coefficient of the valve is almost constant, ranging from 1.53 to 1.56, indicating that it is the inherent flow coefficient of the designed hydrogen shut-off valve.

저자
  • 김나용(경상국립대학교) | Na-Yong Kim
  • 김문학(㈜유니크) | Mun-Hak Kim
  • 이치우(경상국립대학교) | Chi-Woo Lee Corresponding author