KOREASCHOLAR

전투차량용 자동소화시스템에 친환경 소화약제 Novec 1230을 적용한 안정성 및 소화성능 분석 Safety and Extinguishing Performance Analysis of Eco-Friendly Form Fire Extinguishing Agent Novec 1230, Applied to Automatic Extinguishing System for Combat Vehicles

이채윤, 구학근
  • 언어KOR
  • URLhttp://db.koreascholar.com/Article/Detail/440638
한국기계기술학회지 (韓國機械技術學會誌)
제26권 제6호 (2024.12)
pp.1399-1406
한국기계기술학회 (Korean Society of Mechanical Technology)
초록

In this study, fire extinguisher system to which form fire extinguisher agents were adopted was applied to the combat vehicle crew room to apply fire extinguishing performance and acid gas safety that meet the national defense standards. As a result of evaluation and verification, the following conclusions were drawn. For standard fire sizes in the combat vehicle crew's standard model, we ignited using a mixture of Novec 1230 and Halon 1301 form extinguisher agent and released form extinguisher agent after 30 seconds to determine the fire extinguishing time. The amount of acid gas generated met the criteria in all cases. When the fire size was increased to 0.12m2 and a 2.0mm nozzle was used, all of the extinguishing time, the amount of acid gas generated, and the concentration of Novec 1230 met the criteria. Despite the more difficult conditions to extinguish the fire by making the fire larger, it was possible to confirm the extinguishing performance of the Novec 1230 form extinguisher agent and its safety against acid gas.

목차
Abstract
1. 서 론
2. 친환경 소화약제 종류 및 분석
    2.1 할로겐화합물
    2.2 할로겐화합물 소화약제의 열분해 생성물
    2.3 할로겐화합물 소화약제의 환경 영향성
3. 화재 시나리 오 구현 방법
    3.1 화재 모 델
    3.2 화재크기
    3.3 연소 연료와 사전 연소시간
4. 실험 장치 및 방법
    4.1. 실험장치
    4.2. 실험방법
5. 결과 및 고찰
    5.1 Halon 1301 소화약제 자동소화시스템
    5.2 Novec 1230 소화약제 자동소화시스템
    5.3 소화약제 성능 비교
6. 결 론
References
저자
  • 이채윤(PhD Dept. of mechanical system engineering, TongMyong University) | Chae-Yun Lee Corresponding author
  • 구학근(professor, Department of Mechanical system Engineering, TongMyong University in Busan) | Hak-Keun Ku