In this study, fire extinguisher system to which form fire extinguisher agents were adopted was applied to the combat vehicle crew room to apply fire extinguishing performance and acid gas safety that meet the national defense standards. As a result of evaluation and verification, the following conclusions were drawn. For standard fire sizes in the combat vehicle crew's standard model, we ignited using a mixture of Novec 1230 and Halon 1301 form extinguisher agent and released form extinguisher agent after 30 seconds to determine the fire extinguishing time. The amount of acid gas generated met the criteria in all cases. When the fire size was increased to 0.12m2 and a 2.0mm nozzle was used, all of the extinguishing time, the amount of acid gas generated, and the concentration of Novec 1230 met the criteria. Despite the more difficult conditions to extinguish the fire by making the fire larger, it was possible to confirm the extinguishing performance of the Novec 1230 form extinguisher agent and its safety against acid gas.