논문 상세보기

한국방사성폐기물학회

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/430594
모든 회원에게 무료로 제공됩니다.
한국방사성폐기물학회 학술논문요약집 (Abstracts of Proceedings of the Korean Radioactive Wasts Society)
한국방사성폐기물학회 (Korean Radioactive Waste Society)
초록

Detritiation of low-level tritiated water has become global issue after Fukushima accident. Several attempts have been made to reduce the radioactivity of Fukushima tritiated water below legal limit of nuclear plant effluents (~104 Bq·L−1). Various technologies such as water distillation, electrolysis, and catalytic exchange were tested to treat the tritiated water, however, those demand enormous expense to achieve the goal due to low process efficiency. It highlights that the performance enhancement of current technologies is necessary to improve economic feasibility. We have quantitatively evaluated the separation performance of various polymers toward low-level tritium (~105 Bq·L−1) through batch experiments. The polystyrene with grafted by 20 types of functional groups (Tris (2-aminoethyl) amine, dimethylaminomethyl, isocyanate, mercaptomethyl, aminomethyl, hydroxymethyl, triphenylphosphine, morpholine, 2-chlorotrityl amine, 4-(dimethylamino) pyridine, poly (vinyl chloride) carboxylated, poly (4-vinyl pyridine), p-toluenesulfonic acid, p-toluenesulfonyl hydrazide, piperidine, acetyl polystyrene, 2-chlorotrityl chloride, piperazine, diethylene triamine, poly (vinyl chloride)) were suspended in HTO solution (initial activity = 4.7 × 105 Bq·L−1). After the equilibration, the suspension was filtered using 3 kDa membrane filter and the activity in filtrates were quantified by LSC (HIDEX-300 SL). The results demonstrate the detritiation efficiency and separation factors of functional groups toward tritium. Carboxylic group (COOH) showed the most reactive performance as detritiation efficiency of ~4%. Compared to other functional groups, styrene sulfonyl groups including sulfonyl amide (SNH2) and sulfonyl hydrazide (SNHNH2) revealed promising performance for tritium separation as separation factor of 10.97 and 3.85, respectively. However, sulfonyl hydroxide (SOH) which is known as reactive functional group to tritium exchange showed the poor performance (detritiation efficiency: 0.68%; separation factor: 3.02). This study could suggest the promising functional groups for detritiation of low-level tritiated water which can be utilized to enhance the performance of current technologies. For example, reactive functional groups can be grafted on the surface of packing material within distillation tower resulting in the increasing detritiation efficiency.

저자
  • Youngho Sihn(Korea Atomic Energy Research Institute, 111, Daedeok-daero 989beon-gil, Yuseong-gu, Daejeon) Corresponding author
  • Chan Woo Park(Korea Atomic Energy Research Institute, 111, Daedeok-daero 989beon-gil, Yuseong-gu, Daejeon)
  • In-Ho Yoon(Korea Atomic Energy Research Institute, 111, Daedeok-daero 989beon-gil, Yuseong-gu, Daejeon)
  • Hee-Man Yang(Korea Atomic Energy Research Institute, 111, Daedeok-daero 989beon-gil, Yuseong-gu, Daejeon)
  • Ilgook Kim(Korea Atomic Energy Research Institute, 111, Daedeok-daero 989beon-gil, Yuseong-gu, Daejeon)