논문 상세보기

Dose Evaluation of Workers Transporting Spent Resin Drums Treated From the Spent Resin Mixture Treatment Facility

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/430642
모든 회원에게 무료로 제공됩니다.
한국방사성폐기물학회 학술논문요약집 (Abstracts of Proceedings of the Korean Radioactive Wasts Society)
한국방사성폐기물학회 (Korean Radioactive Waste Society)
초록

The dose was evaluated for the workers transporting the spent resin drums from a spent resin mixture treatment facility. The treatment technology of spent resin mixture waste based on microwave was developed to compensate for the shortcoming of the existing one. The mechanism of the facility for the treatment is divided into separation, desorption, condensation and adsorption process. The treated spent resin that has passed through the microwave reactor flows into the spent resin storage tank. As the treatment time elapses, if spent resin accumulates in the spent resin storage tank, it is moved to the drum of the volume of 200 L. The drum must be moved by the worker, in which case radiation exposure to the drum transport worker occurs. It requires the dose evaluation for drum transport workers in terms of radiation safety. Dose evaluation was performed in consideration of the change in the composition ratio and weight of the spent resin mixture, where the working time for transportation was considered from 10 to 120 minutes in 10-minute increment. In the case of 100 kg of the spent resin mixture, the dose range was derived as 4.62×10−3 – 5.90×10−2 mSv for the 100 kg of spent resin, 4.72×10−3– 5.58×10−2 mSv for the 80 kg of spent resin and 20 kg of zeolite and activated carbon, and 5.38×10−3 – 6.32×10−2 mSv for the 60 kg of spent resin and 40 kg of zeolite and activated carbon. In the case of 150 kg of the spent resin mixture, the dose range was derived as 6.83×10−3 – 8.20×10−2 mSv for the 150 kg of spent resin, 7.13×10−3 – 8.22×10−2 mSv for the 120 kg of spent resin and 30 kg of zeolite and activated carbon, and 8.28×10−3 – 8.86×10−2 mSv for the 90 kg of spent resin and 60 kg of zeolite and activated carbon. The estimated maximum doses for each weight (100 kg and 150 kg of mixture) were confirmed to be 3.16×10−1% and 4.43×10−1% of the annual average dose limit of 20 mSv for radiation workers.

저자
  • Jaehoon Byun(Ulsan National Institute of Science and Technology, 50, UNIST-gil, Eonyang-eup, Ulju-gun, Ulsan) Corresponding author
  • Hee Reyoung Kim(Ulsan National Institute of Science and Technology, 50, UNIST-gil, Eonyang-eup, Ulju-gun, Ulsan)