논문 상세보기

Deduction of Appropriate Measurement Time for Gamma Radionuclide Analysis Through the Minimum Detectable Activity of Unknown Sample

  • 언어ENG
  • URLhttps://db.koreascholar.com/Article/Detail/430658
모든 회원에게 무료로 제공됩니다.
한국방사성폐기물학회 학술논문요약집 (Abstracts of Proceedings of the Korean Radioactive Wasts Society)
한국방사성폐기물학회 (Korean Radioactive Waste Society)
초록

Appropriateness of the minimum detectable activity in the analysis of gamma radionuclides is very important. This is reason determine the time factor among the conditions of the analysis when it is rationally determined has the advantage that radioactivity analysis can be performed accurately and quickly. In this study, 100 mL of an unknown sample was diluted in Marinelli Beaker 1L to obtain, review data on gamma radiation analysis results and minimum detectable activity for each measurement time. The measurement was used High Purity Germanium detector, target nuclides are Co-57, Co-58, Y-88 and Cs-137. Since the radioactivity analysis sample will be expected to be the waste subject to selfdisposal or less during the radioactive waste classification, the minimum detectable activity standard was set based on the detection of less than the permissible activity for self-disposal for each nuclide. The measurement methods were measured by classifying it into seven categories: 1000 seconds, 3600 seconds, 10000 seconds, 30000 seconds, 80000 seconds, 100000 seconds, and 150000 seconds. The radioactivity from this measurement are Co-57 2.89 Bq·g−1, Co-58 0.19 Bq·g−1, Y-88 0.20 Bq·g−1, Cs-137 0.15 Bq·g−1, the measurement results under all conditions were similar. On the other hand, the minimum detectable activity showed values above the allowable activity for self-disposal in not but Co-58 at 1000 and 3600 seconds. Only after taking the measurement time of 10000 seconds, the result was derived Co-57 0.0095 Bq·g−1, Co-58 0.0068 Bq·g−1, Y-88 0.0052 Bq·g−1, Cs-137 0.0062 Bq·g−1, which was confirmed to less than the allowable activity for self-disposal by nuclide. Reasonably determining the measurement time in gamma radionuclide analysis is a very important issue in terms of economy of time and accuracy of measurement. Although this study cannot be said to be able to determine a reasonable measurement time for all gamma radionuclide analysis, it is hoped that research on various samples will be made to contribute to the efficient measurement of gamma radioactivity.

저자
  • Sanguk Lee(Sunkwang T&S, 65, Techno 3-ro, Yuseong-gu, Daejeon)
  • Seohyeon Lee(Sunkwang T&S, 65, Techno 3-ro, Yuseong-gu, Daejeon)
  • Jaemin Lee(Sunkwang T&S, 65, Techno 3-ro, Yuseong-gu, Daejeon)
  • Kwanggyun Choi(Gachon University, 1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Sunkwang T&S, 65, Techno 3-ro, Yuseong-gu, Daejeon)
  • Seokhwan Lee(Sunkwang T&S, 65, Techno 3-ro, Yuseong-gu, Daejeon)
  • Jeongsoo Park(Gachon University, 1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Sunkwang T&S, 65, Techno 3-ro, Yuseong-gu, Daejeon)
  • Sangbok Lee(Gachon University, 1342, Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, Sunkwang T&S, 65, Techno 3-ro, Yuseong-gu, Daejeon) Corresponding author