검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2,284

        41.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: Estrus in cows can be detected through vaginal electrical resistance or conductivity. However, there are no studies measuring vaginal electrical resistance in Hanwoo cows. This study aims to measure the vaginal electrical resistance value in Hanwoo cows and compare it with estrus and ovulation. Methods: Vaginal electrical resistance values of 73 Hanwoo cows were measured before and after estrus at the Gyeongsangbuk-do Livestock Research Institute. Measurements were taken on days -6, -3, -2, -1, 0, 1, 2, 3, and 6 of artificial insemination. Large follicles and ovulation were confirmed using transvaginal ultrasonography. Results: The vaginal electrical resistance averaged 225.6 ± 6.3 Ω days before the artificial insemination date, decreasing until the day of artificial insemination. The average vaginal electrical resistance was 163.7 ± 4.6 Ω on the date of artificial insemination, and 188.8 ± 4.3 Ω one day after artificial insemination, when large follicles were observed. In addition, on the 6th day after artificial insemination, the vaginal electrical resistance averaged 231.4 ± 5.5, which was similar to the 6th day before artificial insemination (222.5 ± 6.3). Transvaginal ultrasonography showed that most of the cows ovulated one day after artificial insemination. Conclusions: The accuracy of estrus is high if the vaginal electrical resistance is measured for cows with confirmed estrus, making is a potentially useful for determining the timing of artificial insemination.
        4,000원
        42.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The primary therapeutic approach for Brucella species infections has mainly been based on antibiotic treatment. However, the development of vaccines for brucellosis control remains controversial. Furthermore, there is currently no licensed vaccine available for human brucellosis. This study aims to evaluate the effect of a combination of recombinant protein vaccines against Brucella (B.) abortus infection using a mouse model. Two B. abortus genes, namely dapB and gpm, were cloned and expressed in competent Escherichia (E.) coli DH5α using the pCold-TF vector. Successfully cloned vectors were subjected to PCR amplification using specific primer pairs. The apparent sizes of dapB and gpm were detected at 807 bp and 621 bp, respectively. Besides, the purified recombinant proteins dapB and gpm were detected using SDS-PAGE electrophoresis with correct sizes of 82.86 kDa and 87.61 kDa, respectively. These recombinant proteins were used to immunize mice as a combined subunit vaccine (CSV) to elicit host immunity against B. abortus infection. Mice immunized with CSV exhibited increased proliferation of CD4+ and/or CD8+ T cells at week 7th and 9th before sacrifice, in comparison to the control group. Notably, CSV immunization showed a significant decrease in bacterial burden in the spleen compared to the control group. Altogether, CSV using dapB and gpm induced host adaptive immune response against Brucella infection, suggesting its potential as an effective new subunit vaccine candidate.
        4,000원
        43.
        2023.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        In this review, the regulatory mechanisms of autophagy were described, and its interaction with apoptosis was identified. The role of autophagy in embryogenesis, tooth development, and cell differentiation were also investigated. Autophagy is regulated by various autophagy-related genes and those related to stress response. Highly active autophagy occurrences have been reported during cell differentiation before implantation after fertilization. Autophagy is involved in energy generation and supplies nutrients during early birth, essential to compensate for their deficient supply from the placenta. The contribution of autophagy during tooth development, such as the shape of the crown and root formation, ivory, and homeostasis in cells, was also observed. Genes control autophagy, and studying the role of autophagy in cell differentiation and development was useful for understanding human aging, illness, and health. In the future, the role of specific mechanisms in the development and differentiation of autophagy may increase the understanding of the pathological mechanisms of disease and development processes and is expected to reduce the treatment of various diseases by modulating the autophagic phenomenon.
        4,300원
        44.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we examined the antagonistic effects of sprout-borne lactic acid bacteria (LAB) on Salmonella enterica serovar Enteritidis. This antagonism is promoted as a means of controlling contamination during sprout production and provides additional LAB for consumers. We isolated a total of 24 LAB isolates in nine species and five genera from seven popular vegetable sprouts: alfalfa (Medicago sativa), clover (Trifolium pratense), broccoli (Brassica oleracea ssp. italica), vitamin (B. rapa ssp. narinosa), red radish (Raphanus sativus), red kohlrabi (B. oleracea var. gongylodes), and Kimchi cabbage (B. campestris var. pekinensis). Based on 16S rRNA gene sequences, the LAB species were identified as Enterococcus casseliflavus, E. faecium, E. gallinarum, E. mundtii, Lactococcus taiwanensis, Leuconostoc mesenteroides, Pediococcus pentosaceus, and Weissella cibaria, and W. confusa. A total of 16 LAB isolates in seven species including E. faecium, E. gallinarum, E. mundtii, L. taiwanensis, L. mesenteroides, P. pentosaceus, and W. cibaria showed antagonistic activity toward S. enterica. The growth inhibition of sprout LAB on S. enterica was confirmed by co-culture. Unexpectedly, sprout LAB failed to suppress the growth of S. enterica in alfalfa sprouts, whereas all LAB strains stimulate S. enterica growth even if it is not significant in some strains. The findings of this study indicate that S. enterica-antagonistic LAB are detrimental to food hygiene and will contribute to further LAB research and improved vegetable sprout production.
        4,000원
        51.
        2023.11 구독 인증기관·개인회원 무료
        Chelating agents, such as ethylenediaminetetraacetic acid (EDTA), diethylenetriaminepentaacetic acid (DTPA), and nitrilotriacetic acid (NTA) are widely used in industry and agriculture as water softeners, detergents, and metal chelating agents. In wastewater treatment plants, a significant amount of chelating agents can be discharged into natural waters because they are difficult to degrade. Since those compounds affect the mobility of radionuclides or heavy metals in decontamination operations at nuclear facilities and radioactive waste disposal, quantification of the amount of ligand is very important for safe nuclear waste management. To predict the behavior of the main complexation in sample matrices of radioactive wastes, it is essential to evaluate the distribution of the metal-chelating species and their stabilities in order to develop analytical techniques for quantifying chelating agents. We have investigated to collect information on the pH speciation of metal chelation and the stability constants of metal complexes depending on three chelating agents (EDTA, DTPA, and NTA). For example, Zhang’s group recently reported that the initial coordination pH of Cu(II) and EDTA4− is delayed with the addition of Fe(III), and the pH range for the stable existence of [Cu(EDTA)]2− is narrowed compared to when it is alone in the sample matrix. The addition of Fe(III) clearly impacts the chemical states of the Cu(II)-EDTA solution. Additionally, Eivazihollagh’s group demonstrated differences in the speciation and stability of Cu(II) species between Cu(II) and three chelating ligands (EDTA, DTPA, and NTA). This study will be greatly helpful in identifying the sample matrix for binding major chelating agents and metals as well as developing chemically sample pretreatment and separation methods based on the sample matrix. Finally, these advancements will enable reliable quantitative analysis of chelating agents in decommissioning radioactive wastes.
        52.
        2023.11 구독 인증기관·개인회원 무료
        One of the important components of a nuclear fuel cycle facility is a hot cell. Hot cells are engineered robust structures and barriers, which are used to handle radioactive materials and to keep workers, public, and the environment safe from radioactive materials. To provide a confinement function for these hot cells, it is necessary to maintain the soundness of the physical structure, but also to maintain the negative pressure inside the hot cell using the operation of the heating, ventilation, and air conditioning (HVAC) systems. The negative pressure inside the hot cells allows air to enter from outside hot cells and limits the leakage of any contaminant or radioactive material within the hot cell to the outside. Thus, the HVAC system is one of the major components for maintaining this negative pressure in the hot cell. However, as the facility ages, all the components of the hot cell HVAC system are also subject to age-related deterioration, which can cause an unexpected failure of some parts. The abnormal operating condition from the failure results in the increase of facility downtime and the decrease in operating efficiency. Although some major parts are considered and constructed in redundancy and diversity aspects, an unexpected failure and abnormal operating condition could result in reduction of public acceptance and reliability to the facility. With the advent of the 4th Industrial Revolution, prognostics and health management (PHM) technology is advancing at a rapid pace. Korea Hydro & Nuclear Power, Siemens, and other companies have already developed technologies to constantly monitor the integrity of power plants and are applying the technology in the form of digital twins for efficiency and safety of their facility operation. The main point of PHM, based on this study, is to monitor changes and variations of soundness and safety of the operation and equipment to analyze current conditions and to ultimately predict the precursors of unexpected failures in advance. Through PHM, it would be possible to establish a maintenance plan before the failure occurs and to perform predictive maintenance rather than corrective maintenance after failures of any component. Therefore, it is of importance to select appropriate diagnostic techniques to monitor and to diagnose the condition of major components using the constant examination and investigation of the PHM technology. In this study, diagnostic techniques are investigated for monitoring of HVAC and discussed for application of PHM into nuclear fuel cycle facilities with hot cells.
        53.
        2023.11 구독 인증기관·개인회원 무료
        South Korea’s first commercial nuclear reactor, Kori Unit 1, was permanently shut down in 2017, and preparations are currently underway for its decommissioning. After the permanent shutdown, the spent nuclear fuel from the reactor core is removed and stored in a spent fuel storage facility. Subsequently, steps are taken for its permanent disposal, and if a permanent disposal site is not determined, it is stored in an interim storage facility (or temporary storage facility). Therefore, the activation criteria for radiation emergency plans vary depending on the movement of spent nuclear fuel and the storage location. In this study, it reviewed emergency plans in the U.S. NRC Regulatory Guide (Draft) titled ‘Emergency Planning for Decommissioning Nuclear Power Reactors’ to determine the requirements for radiation emergency plans needed for decommissioned nuclear power plants. Additionally, by examining emergency plans applied to decommissioning nuclear power plants in the United States, this study identified emergency plan requirement that could be applicable to future decommissioned nuclear power plants in South Korea. This study will contribute to the establishment of appropriate radiation emergency plans for decommissioning nuclear power plants in Korea for providing accurate information on overseas cases and relevant guidelines.
        54.
        2023.11 구독 인증기관·개인회원 무료
        Detectors utilized for nuclear material safeguards have been using scintillation detectors which are inexpensive and highly portable, and electrically cooled germanium detectors which are expensive but have excellent energy resolution. However, recently IAEA, the only international inspectorate of nuclear material safeguards for the globe, have replaced the existing scintillation detector and electrically cooled germanium detector with a CdZnTe detector owing to the improved performance of room-temperature semiconductors significantly. In this paper, we will examine the spectrum features of the CdZnTe detector such as spectrum shape, energy resolution, and efficiency in the energy region of interest, which are the important characteristics for measuring Uranium enrichment. For this purpose, it would be conducted to compare its spectrum features using CdZnTe, NaI, HPGe detectors. The main energies of interest include 185.7 keV and 1,001 keV, which are the decay energies of uranium 235 and uranium 238. The results of this study will provide a better understanding of the spectral features of various detectors used in uranium enrichment analysis, and are expected to be used as basic data for future related software development.
        55.
        2023.11 구독 인증기관·개인회원 무료
        In nuclear power plant (NPP) decommissioning, ventilation and purification of the building atmosphere are important to create a working environment, ensure worker safety, and prevent the release of gaseous radioactive materials into the environment. The heating, ventilation, and air conditioning (HVAC) system of each building is maintained, modified, or newly installed. In this study, based on APR1400, operation strategies were presented in case of ventilation abnormalities in the reactor containment building (RCB), where highly radioactive particles and high dust are most frequently generated during NPP decommissioning. For research, it was assumed that the entire RCB atmospheric ventilation during decommissioning would use the RCB purge system of the existing NPP and perform continuous ventilation. Additionally, it is assumed that areas where high radiation particles and high dust occur locally, such as reactor containers or internal segments, are sealed with tents and purified using a HEFA filter of a temporary portable HVAC, and a exhaust flow path is connected to the discharge duct of the existing RCB purge system. The possibility of abnormal occurrence was largely divided into two cases. First, when large amounts of uncontrolled pollutants are released into the atmosphere inside the RCB, discharge to the environment is stopped manually or automatically by a modified engineered safety function activation signal (ESFAS). Afterwards, the RCB purge system should be operated in recirculation mode to sufficiently purify the RCB atmosphere with a HEPA filter. Second, when the first train of the low volume purge system is not running due to a failure, standby train should be operated. If both low volume purge trains fail, a high volume purge system is used. Intermittent purge operation is preferred due to large capacity during high volume purge operation. In cases where it is not possible to operate all purge systems due to common issues such as power supply, atmospheric sampling is performed to determine whether to proceed with the work inside RCB.
        56.
        2023.11 구독 인증기관·개인회원 무료
        The radiological characterization of SSCs (Structure, Systems and Components) plays one of the most important role for the decommissioning of KORI Unit-1 during the preparation periods. Generally, a regulatory body and laws relating to the decommissioning focus on the separation and appropriate disposal or storage of radiological waste including ILW (intermediate level waste), LLW (low level waste), VLLW (very low level waste) and CW (clearance waste), aligned with their contamination characteristics. The result of the preliminary radiological characterization of KORI Unit-1 indicated that, apart from neutron activated the RV (reactor vessel), RVI (reactor vessel internals), and BS (biological shielding concrete), the majorities of contamination were sorted to be less than LLW. Radiological contamination can be evaluated into two methods. Due to the difficulties of directly measuring contamination on the interior surfaces of the pipe, called CRUD, the assessment was implemented by modeling method, that is measuring contamination on the exterior surfaces of the pipes and calculating relative factors such as thickness and size. This indirect method may be affected by the surrounding radiation distribution, and only a few gamma nuclides can be measured. Therefore, it has limitation in terms of providing detailed nuclide information. Especially, α and β nuclides can only be estimated roughly by scaling factors, comparing their relative ratios with the existing gamma results. To overcome the limitation of indirect measurement, a destructive sampling method has been employed to assess the contamination of the systems and component. Samples are physically taken some parts of the systems or components and subsequently analyzed in the laboratory to evaluate detailed nuclides and total contamination. For the characterization of KORI Unit-1, we conducted the radiation measurement on the exterior surfaces of components using portable instruments (Eberline E-600 SPA3, Thermo G20-10, Thermo G10, Thermo FH40TG) at BR (boron recycle system) and SP (containment spray system) in primary system. Based on these results, the ProUCL program was employed to determine the destructive sample collection quantities based on statistical approach. The total of 5 and 8 destructive sample quantities were decided by program and successfully collected from the BR and SP systems, respectively. Samples were moved to laboratory and analyzed for the detail nuclide characteristics. The outcomes of this study are expected to serve as valuable information for estimating the types and quantities of radiological waste generated by decommissioning of KORI Unit-1.
        57.
        2023.11 구독 인증기관·개인회원 무료
        The Derived Concentration Guideline Level (DCGL) is required to release the facility from the nuclear safety act at the stage of site restoration of the decommissioning nuclear power plant. In order to evaluate DCGL, there are various requirements, and among them, the selection of input parameters based on the application scenario is the main task. Especially, it is important to select input parameters that reflect site characteristics, and at this time, a single deterministic value or a probabilistic distribution can be applied. If it is inappropriate to apply a particular single value, it may be reasonable to apply various distributions, and the RESRAD code provides for evaluation using probabilistic methods. Therefore, this study aims to analyze the difference between the application of the deterministic method and the application of the probabilistic method to the area and thickness of the contaminated zone among the site characteristics data. This study analyzed the thickness and area of the contaminated zone, and in the case of thickness, the deterministic method was applied by changing the thickness at regular intervals from the minimum depth considered by MARSSIM to the thickness of the unsaturated zone identified in previous research data. In addition, a probabilistic analysis was performed by applying a distribution to the thickness of contaminated zone. Second, for the area of the contaminated zone, the dose was evaluated for each area in consideration of the areas to be considered when deriving Area Factor (AF), and the resulting change in DCGL was observed. As a result, the DCGL tends to decrease as the thickness increases, and it seems to be saturated when the thickness exceeds a certain thickness. Therefore, It was confirmed that the level of saturated values is similar to that of entering a probabilistic distribution, and in the case of a parameter that is reasonable to enter as a distribution rather than as a single value, it is sufficiently conservative to perform a probabilistic evaluation. In the case of area change, the DCGL evaluation result showed that the DCGL increased as the scale decreased. The magnitude of the change varies depending on the characteristics of each radionuclide, and in the case of radionuclides where external exposure gamma rays have a major exposure effect, the change is relatively small. It can be seen that the change in DCGL according to the area has the same tendency as the AF applicable to the survey unit for small survey units applied in the final status survey.
        58.
        2023.11 구독 인증기관·개인회원 무료
        As unit 1 of Kori was permanently shut down in June 2017, domestic nuclear industry has entered the path of decommissioning. The most important thing in decommissioning is cost reduction. And volume reduction of radioactive waste is especially important. According to the IAEA report, more than 4,000 tons of metallic waste is generated during the decommissioning of a 1,000 MWe reactor and most of these wastes are LLW or VLLW. To reduce amount of metallic waste dramatically, we should choose efficient decontamination method. In this study, we conducted dry ice and bead blasting decontamination. We prepared Inconel-600 and STS-304 specimen with dimensions of 30 mm × 30 mm × 5 mm. Loose and fixed contamination was applied on the surface of specimen using SIMCON method. Bead and dry-ice blasting was conducted by spraying alumina and dry ice pellet at the same pressure and distance for the same time. The removal of loose contamination was observed using microscope. It was found that contaminants are significantly removed using both dry ice blasting and bead blasting. However, some abrasive material remained on the surface of specimen. The removal of fixed contamination was verified by weight comparison before and after experiment and cobalt concentration comparison before and after experiment using X-ray Fluorescence Spectroscope (XRF). At least 90% of the cobalt was removed, but some abrasive particle was also remained on the surface of specimen. In this study, it is confirmed that the effectiveness of manufacturing a large-scale abrasive decontamination facility, and it is expected that this technology can be used to effectively reduce the amount of metallic waste generated during decommissioning.
        59.
        2023.11 구독 인증기관·개인회원 무료
        Domestic commercial low- and intermediate-level radioactive waste storage containers are manufactured using 1.2 mm thick cold-rolled steel sheets, and the outer surface is coated with a thin layer of primer of 10~36 μm. However, the outer surface of the primer of the container may be damaged due to physical friction, such as acceleration, resonance, and vibration during transportation. As a result, exposed steel surfaces undergo accelerated corrosion, reducing the overall durability of the container. The integrity of storage containers is directly related to the safety of workers. Therefore, the development of storage containers with enhanced durability is necessary. This paper provides an analysis of mechanical properties related to the durability of WC (tungsten carbide)-based coating materials for developing low- and intermediate-level radioactive waste storage containers. Three different WC-based coating specimens with varied composition ratios were prepared using HVOF (high-velocity oxy-fuel) technique. These different specimens (namely WC-85, WC-73, and WC-66) were uniformly deposited on cold-rolled steel surfaces ensuring a constant thickness of 250 μm. In this work, the mechanical properties of the three different WCbased coaitng materials evaluated from the viewpoints of microstructure, hardness, adheision force between substrate and coating material, and wear resistance. The cross-sectional SEM-EDS (Scanning Electron Microscope-Energy Dispersive X-ray Spectroscopy) images revealed that elements W (tungsten), C (carbon), Ni (nickel), and Cr (chromium) were uniformly distributed within the each coating layers which was approximately 250 μm thick. The average hardness values of HWC-85 and HWC-73 were found to be 1,091 Hv (Vickers Hardness) and 1,083 Hv, respectively, while the HWC-66 exhibited relatively lower hardness value of 883 Hv. This indicates that a higher WC content results in increased hardness. Adhesion force between and substrates and coating materials exceeded 60 MPa for all specimens, however, there were no significant differences observed based on the tungsten carbide content. Furthermore, a taber-type abrasion tester was used for conducting abrasion resistance tests under specific conditions including an H-18 load weight at 1,000 g with rotational speed set at 60 RPM. The abrasion resistance tests were performed under ambient temperatures (RT: 23±2°C) as well as relative humidity levels (RH: 50±10%). Currently, the ongoing abrasion resistance tests will include some results in this study.
        60.
        2023.11 구독 인증기관·개인회원 무료
        As the acceptance criteria for low-intermediate-level radioactive waste cave disposal facilities of Korea Radioactive Waste Agency (KORAD) were revised, the requirements for characterization of whether radioactive waste contains hazardous substances have been strengthened. In addition, As the recent the Nuclear Safety and Security Commission Notice (Regulations on Delivery of Low- Medium-Level Radioactive Waste) scheduled to be revised, the management targets and standards for hazardous substances are scheduled to be specified and detailed. Accordingly, the Korea Atomic Energy Research Institute (KAERI) needs to prepare management methods and procedures for hazardous substances. In particular, in order to characterize the chemical requirements (explosiveness, ignitability, flammability, corrosiveness, and toxicity) contained in radioactive waste, it must be proven through documents or data that each item does not contain hazardous substances, and quality assurance for the overall process must be provided. In order to identify the characteristics of radioactive waste that will continue to be generated in the future, KAERI needs to introduce a management system for hazardous substances in radioactive waste and establish a quality assurance system. Currently, KAERI is thoroughly managing chelates (EDTA, NTA, etc.), but the detailed management procedures for hazardous substances related to chemical requirements in radioactive waste in the radiation management area specified above are insufficient. The KAERI’s Laboratory Safety Information Network has a total periodic regulatory review system in place for the purchase, movement, and disposal of chemical substances for each facility. However, there is no documents or data to prove that the hazardous substances held in the facility are not included in the radioactive waste, and there are no procedures for managing hazardous substances. Therefore, it is necessary to establish procedures for the management of hazardous substances, and we plan to prepare management procedures for hazardous substances so that chemical substances can be managed according to the procedures at each facility during preliminary inspection before receiving radioactive waste. The procedure provides definitions of terms and types of management targets for each characteristic of the chemical requirements specified above (explosiveness, ignition, flammability, corrosiveness, and toxicity). In addition, procedure also contains treatment methods of radioactive waste generated by using hazardous substances and management methods of in/out, quantity, history of that substances, etc. As the law is revised in the future, management will be carried out according to the relevant procedures. In this study, we aim to present the hazardous substance management procedures being established to determine whether radioactive waste contains hazardous substances in accordance with the revised the notice and strengthened acceptance criteria. Through this, we hope to contribute to improving reliability so that radioactive waste could be disposed of thoroughly and safely.
        1 2 3 4 5