검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 55

        49.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A core device of foam system is the in-line eductor and it is the device to mix the foam liquid into liquid solution proper to the use density and the mixture ratio must be kept regularly regardless of changing fluid condition of the front and rear end of the in-line eductor. However, if the flux of the pressurized water changes, the mixture ratio is not kept regularly, and so it becomes a cause which a performance of fire-extinguishing deteriorates in discharging foam liquid. I devise a method to improve it that the metering orifice type in-line eductor is improved into the metering venturi type in-line eductor, the fluctuation of the mixture ratio to the flux change of the pressurized water is minimized and the performance of fire-extinguishing is kept regularly. As this method is simple in its structure and can be designed at a low cost, it helps for maintenance as well. In the future, it seems to need the research for the metering nozzle type in-line eductor in the future.
        4,000원
        50.
        2011.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The automatic fire detection system is an important facility installed with focusing on minimizing the damage from a fire. This paper presents in the followings as the methods to reduce the false alarm of the automatic fire detection system; first, to prepare for legal standard so that revised legal standard can be applied to the fire fighting property prior to revision; second, to introduce the performance based fire detection protection design in the law based fire protection design; third, to maintain the wiring of worn-out detector; forth, to introduce an evaluation system to the education for the fire warden; fifth, to extend the standard of MTBF(meantime between failure) of the detector; sixth, to extend of installing the analog type detector; seventh, to improve the structure of reset switch.
        4,000원
        51.
        2009.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the fire there are fusion signs and damage by fire, and insulation aging and carbonization of the electric wiring in the ignition spot because of special characteristic of the appliance in the electricity fire. Because of the physical factor applied in the damage of fire, the decision of ignition spot by eye investigation is insufficient. In this paper, the cause of electricity fire is researched. The focus is on the operation state of operated MCCB(Molded Case Circuit Breaker) at the time of electricity fire. Through grasping the operation principle of MCCB and the experiment, the state of MCCB after fire suppression is discriminated. The distinction possibility on the exist of electricity fire is proposed.
        4,000원
        52.
        2009.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study set three kinds of situation and observed the various states such as carbonization by experimenting damages by fire of electric iron. The results of this study are as follows: The fire did not occurred when the unpowered iron over mattress and cotton shirts was com busted completely by external flame because the temperature of surface of soleplate and mattress did not reach the minimum ignition energy and when the powered electric iron over mattress and cotton shirts was left for an hour with its temperature dial set to high because the temperature of combustibles did not reach the minimum ignition energy. The fire occurred when the electric iron in which the outer box, bi-metal switch, and temperature fuse were removed over mattress and cotton shirts was powered by through heater terminal, and then the electric iron, mattress, and cotton shirts were combusted by the fallen combustibles because the temperature of combustibles reached to the minimum ignition energy with the help of active transfer of heat.
        4,000원
        53.
        2009.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This research has so far found out problems including the second damage of extinguishant and the short time of emission when using the existing dry chemical extinguisher and gas type extinguisher, and impossibility of constant extinguishing due to the inability of recharge at the field. To solve such problems, a mobile water mist system was developed and used. However, it is judged that more improved mobile water mist system is necessary because the force of the fire changed diversely and remote villages in mountains or islands where the force of fire extinguishing is short or delayed, require high capacity of fire extinguishing. Therefore a new equipment was developed and tested focusing on the improvement of extinguishing capacity and the performance of extinguishing was found out to be improved, compared to the existing mobile water mist system. It also showed a superior extinguishing capacity to dry chemical extinguisher or gas type extinguisher. Afterward an additional research is required of simplification of equipment, price cutting and the development of additive to enable high performance even with just small extinguishant.
        4,300원
        54.
        2008.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently as the testing of fire detector used the testing device for fire detector, there are something the matter in the perception function loss of fire detector, structure and form of the testing device for fire detector. The problem at oxidation of emitting smoke ashes hazardous article part and so on that checking person absorbs be. In this paper the problem or the conventional the examination equipment of fire detectors is analysed and researched. To solve these problems after the theoretical study and design and paint drawing of equipment the prototype of composite examination equipment of fire detectors was made. After compared with the conventional, part that improve of composite examination equipment of fire detectors are verified through the examination. In the future it will be useful the operation state and correct operation time of the fire detectors are measured after the research about the quality of the material and transparency of bellows cover is done.
        4,000원
        55.
        2008.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to distinguish the causes of broken glass on doors or windows when it is originally kept among the remains on the floor in fire site - whether it was broken due to heating or outer power-through test and characteristics of the broken plane including the pattern on the plane. Addition to it, the study tries to find characteristics to judge the point and direction of breakdown through the analysis of glass broken by outer power. With two assumed causes - a) breakdown due to heating and b) breakdown due to outer power-3 pieces of glass plates (30cm×30cm×5mm) were tested for each case, getting the results as following: First, for the glass broken due to the change of temperature, the broken plane is of slow and smooth curve without any pattern. Second, for the glass broken due to outer power, with the impact point as the center, the glass shows breakdown of radial type and the side shows breakdown of near-perpendicular type. The far the broken piece is from the impact point, the bigger the size is. The broken piece at the impact point is of long triangle type and the two long planes of the triangle shows semi-arc with the center of breakdown point and the other plane shows opposite pattern. Third, when glass that is damaged by outer power is heated, damaged forms and side patterns of the glass that is damaged by outer power are heated and disappeared.
        4,000원
        1 2 3