검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 199

        21.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to investigate whether dietary levels of copra and palm meals affect the growth performance, carcass characteristics, and meat properties of Hanwoo steers. Eighty-one Hanwoo steers were randomly assigned to one of three dietary groups: T1 (conventional level of palm and copra meals), T2 (20% copra meal and 15% palm meal), and T3 (30% copra meal and 20% palm meal). During the growing and early fattening periods, the average daily gains and formula feed intakes of T2 and T3 were higher than that of T1; however, those differences were not statistically significant. The dietary levels of copra and palm meals did not affect carcass weight, back fat thickness, and rib-eye areas. Marbling scores and meat quality grades were lower in T3 than in T1 and T2; however, those differences were not statistically significant. Meat color, fat color, texture, and maturity were similar among the treatment groups. In addition, dietary levels of copra and palm meals did not affect the chemical and fatty acid composition of longissimus dorsi muscles in Hanwoo steers. Thus, the present results indicate that high supplementation levels of copra and palm meals do not negatively affect the growth performance, carcass characteristics, and meat properties of Hanwoo steers.
        4,000원
        23.
        2017.06 구독 인증기관·개인회원 무료
        목적: 소프트 콘택트렌즈를 착용하는 건성안 피검자를 대상으로 권장 시간 이상 콘택트렌즈를 착용 했을 때 시력 및 stray light 값의 변화를 확인하고, 이 때 인공눈물 점안을 통해 시력 및 stray light 값의 변화에 인공눈물이 긍정적 영향을 미치는 지에 대해 알아보고자 하였다. 방법: 소프트 콘택트렌즈를 착용하는 젊은 성인 150명 대상으로 Mcmonnies Dry Eyes Q. 및 Ocular Surface Disease Index 설문 결과 실시 후에 건성안 의심 22명을 선별하여 TBUT 검사를 통해 16명의 건성안 환자를 정하였고, 대상자들은 소프트 콘택트렌즈 하루 권장 착용시간 이상 착용 전, 후 시력 및 C-Quant 검사를 실시하여 시력 및 stray light 값 변화의 유무를 관찰 하였다. 이 후 인공눈물(Refresh Plus, Allergan 社)을 점안하여 시력 검사 및 C-Quant 검사를 재실시 하여 관련된 변화가 나타나는지를 확인하였다. 결과: 대상자들의 렌즈 착용 후 실시한 사전 검사에서 평균 시력은 양안 1.0±0.15, 우안 0.90±0.15, 좌안 0.90±0.15로 측정되었고 이를 기준으로 8시간 후 인지한 시표의 평균 개수가 양안 –1.66±0.98, 우안 –2.00±1.80, 좌안 -2.38±1.54(수치 앞 +/-는 사전 시력 검사 와 비교하여 읽은 시표 개수의 증감을 의미)으로 사전검사 대비 시표 인지 개수가 감소 하였으며 대상자 전원 시표 인지 개수의 감소가 관찰되었다. 인공눈물 투여 후 재검사를 실시하였을 때 평균 시력은 양안 1.08±0.14, 우안 0.95±0.11, 좌안 0.92±0.15로 상대적으로 상승하였고, 인식한 시표 개수는 양안 3.46±2.85, 우안 3.98±3.29, 좌안 5.50±4.68로 모두 증가하였다. 인공눈물 투여 전, 후 C-Quant 검사 결과 평균 stray light 값은 1.07±0.19 에서 1.07±0.25로 유의한 변화는 관찰되지 않았다. 결론: 건성안 피검자의 경우 권장시간 이상 소프트 콘택트렌즈를 착용 했을 시 상대적으로 시력의 감소가 발생하였으며 인공눈물의 점안을 통하여 시력을 상대적으로 회복 할 수 있었다.
        24.
        2016.12 KCI 등재 구독 인증기관·개인회원 무료
        적 : 삼각 섬유성 연골 파열환자의 자기공명영상 검사 시 3D FSPGR with Fat Saturation 기법과 Isotropic 3D FSE with Fat Saturation 기법을 비교하여 삼각 섬유성 연골 파열 환자를 관찰하기 위한 Isotropic 3D FSE with Fat Saturation 기법의 유용성에 대하여 평가하고자 하였다. 대상 및 방법 : 2015년 10월부터 2015년 12월까지 삼각 섬유성 연골 손상을 주호소로 본 기관을 내원한 환자 9명(남: 5명 여: 4명)을 대상으로 하였으며, 3D FSPGR with Fat Saturation 기법과 Isotropic 3D FSE with Fat Saturation 기법을 통해 획득한 관상면 영상과 획득한 영상을 축상면 및 시상면으로 재구성한 영상을 가지고 삼각 섬유성 연골과 월상골, 배경신호의 신호강도 값을 측정하여, SNR 및 CNR 값을 계산하고, Mann-Whitney U-검정으로 두 기법간의 통계적 유의성을 검증하여 정량적 평가를 하였다. 또한 정성적 평가는 영상의학의 2명이 각각의 영상을 관찰하여, 삼각 섬유성 연골의 형태, 영상 내 인공음영, 병변의 묘사 정도의 3가지 항목을 선정한 후 이를 4점 척도(0: 진단 불가, 1: 부족함, 2: 충분함, 3: 좋음)로 평가하였고, Kappa-Value을 이용하여 두 관찰자간의 일치도 검증을 하였다. 영상획득에는 3.0 T MR 장비와 Extremity RF Coil을 사용하였다. 결 과 : 정량적 평가 결과, SNR의 평균값은 3D FSPGR with Fat Saturation 기법의 경우 관상면, 재구성 축상면, 재구성 시상면이 각각 19.00±1.96, 17.69±1.52, 17.84±1.12의 값을 나타내었고, Isotropic 3D FSE with Fat Saturation 기법의 경우는 각각 22.62±1.00, 20.64±1.53, 20.23±1.70 의 값을 나타내었다. CNR 평균값의 비교는 3D FSPGR with Fat Saturation 기법의 경우 관상면, 재구성 축상면, 재구성 시상면이 각각 18.62±1.19, 10.41±1.30, 10.28±1.18의 값을 나타내었고, Isotropic 3D FSE with Fat Saturation 기법의 경우 각각 22.62±1.00, 17.69±1.39, 17.35±1.64의 값을 나타내었다. 모든 영상 단면에서 SNR값 및 CNR값이 Isotropic 3D FSE with Fat Saturation 기법이 높게 나타났으며, 통계적으로도 유의하였다.(p<0.05) 정성적 평가 결과에서 관찰자1의 경우, 3D FSPGR with Fat Saturation 기법에서는 삼각 섬유성 연골의 형태, 인공음영, 병변의 묘사 정도가 각각 관상면에서는 2.51±0.5, 2.33±0.5, 2.44±0.5이고, 재구성 축상면에서는 2.33±0.5, 2.22±0.4, 2.44±0.5이고, 재구성 시상면에서는 2.33±0.5, 2.33±0.5, 2.33±0.5의 값을 나타내었다. Isotropic 3D FSE with Fat Saturation 기법에서는 삼각 섬유성 연골의 형태, 인공음영, 병변의 묘사 정도가 각각 관상면에서는 2.77±0.4, 2.77±0.5, 2.77±0.4 이고, 재구성 축상면에서는 2.88±0.3, 2.88±0.3, 2.88±0.3이고, 재구성 시상면에서는 2.66±0.5, 2.88±0.3, 2.77±0.4 의 값을 나타내었다. 관찰자2의 경우, 3D FSPGR with Fat Saturation 기법에서는 삼각 섬유성 연골의 형태, 인공음영, 병변의 묘사 정도가 각각 관상면에서는 2.55±0.5, 2.33±0.5, 2.44±0.5이고, 재구성 축상면에서는 2.33±0.5 2.33±0.5, 2.55±0.5이고, 재구성 시상면에서는 2.22±0.4, 2.33±0.5, 2.55±0.5의 값을 나타내었다. Isotropic 3D FSE with Fat Saturation 기법에서는 삼각 섬유성 연골의 형태, 인공음영, 병변의 묘사 정도가 각각 관상면에서는 2.88±0.3, 2.77±0.4, 2.77±0.4이고, 재구성 축상면에서는 2.88±0.3, 2.88±0.3, 2.88±0.3이고, 재구성 시상면에서는 2.66±0.5, 2.88±0.3, 2.66±0.5의 값을 나타내었다. Isotropic 3D FSE with Fat Saturation 영상 기법의 평가 결과가 더 높게 나타났으며, Kappa-value 검증을 이용한 두 관찰자 간 평가 결과의 일치도 검증도 통계적으로 유의하였다.(p<0.05) 결 론 : 삼각 섬유성 연골 파열환자에서 3D FSPGR with Fat Saturation 기법과 Isotropic 3D FSE with Fat Saturation 기법을 이용하여 비교 분석 한 결과 Isotropic 3D FSE with Fat Saturation 기법이 삼각 섬유성 연골 병변의 감별에 보다 많은 진단적 정보를 제공 할 수 있을 것이라 생각된다.
        25.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 식품접객업소 등에서 사용되는 94건의 물수건(위생처리업소 39건, 식품접객업소 55건)에 대하여 위생 지표세균, 중금속, 염소부산물 등에 대한 안전성을 조사하였다. 중금속 안전성 조사결과 납은 불검출 ~ 0.41 mg/kg(불검출 75건), 비소는 불검출 ~ 0.25 mg/kg(불검출 93건), 카드뮴은 불검출 ~ 0.01 mg/kg(정량한계 미만 7건, 불검출 87건), 수은은 0.003 mg/kg ~ 0.09 mg/kg, 6가크롬은 모든 시료에서 검출되지 않았다. 이 중 납의 검출량이 가장 많았으나, 가장 높은 검출량인 0.41 mg/kg조차 납 규격기준(20 mg/kg 이하)의 2.1%로 매우 낮은 수준이었다. 미생물 안전성의 경우 대장균은 모든 시료에서 음성이었으며, 일반 세균수는 43건 양성이고, 그 중 24건은 규격기준을 초과 하였다. 물수건의 포장상태는 세균의 오염 및 물수건 간의 교차오염에 큰 영향을 끼치는 것으로 확인할 수 있었다. 포장에 따른 미생물 오염 비교결과는 덕용포장이고 개봉포장일 때 세균의 오염이 가장 높았다. 수거 시 위생물 수건의 수분함량과 미생물의 상관관계를 확인해본 결과 유의성은 없었으며, 각 시료별 수분함량은 50.0% ~ 77.0%(평균 61.9%)이었다. 물수건 소독에 사용되는 염소화합물 로부터 유래되는 염소부산물(클로라이트, 클로레이트)은 88건 중 17건(19.3%)에서 검출되었다. 본 연구결과는 물수건의 제조업 및 식품접객업 종사자의 교육 및 안전관리 정책의 기초자료로 활용할 수 있을 것으로 생각된다.
        4,000원
        26.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        URPOSES: The objective of this study was to develop an impact resonance (IR) test procedure for thin disk-shaped specimens in order to determine the ⎢E*⎢ and phase angle values of various asphalt mixtures. METHODS: An IR test procedure was developed for evaluating thin disk-shaped specimens, in order to determine the dynamic modulus (⎢E*⎢) of various asphalt mixtures. The IR test method that was developed to determine the elastic modulus values of Portland cement concrete was evaluated, which method uses axisymmetric flexural vibration proposed by Leming et al. (1996). The IR tests were performed on three different mixtures of New York with varying nominal maximum aggregate sizes (NY9.5, NY19, and NY25) at six different temperatures (10 - 60℃). The ⎢E*⎢ values obtained from the IR tests were compared with those determined by the commonly used AASHTO T342-11 test. RESULTS AND CONCLUSIONS : The IR test method was employed to determine the ⎢E*⎢ values of thin-disk-shaped specimens of various asphalt mixtures. It was found that the IR test method when used with thin disk-like specimens is a simple, practical, and cheap tool for determining the ⎢E*⎢ values of field cores. Further, it was found the ⎢E*⎢ values obtained from the IR tests using thin disk-like specimens were almost similar to those obtained using the AASHTO T342-11 test.
        4,000원
        27.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 비만에 의한 대사성 질환들을 관리하고 예방하기 위해서 체내 지방의 정량적 분포를 정확하고 반복적으로 측정하는 것은 임상적, 연구적 목적으로 아주 중요하다고 할 수 있다. 본 연구는 CT를 이용한 복부지방용적 측정값을 표준으로 설정한 후, 3D Gradient dual echo 2-point DIXON 기법의 MR 영상으로 측정한 복부지방용적 및 그 분포 비율 측정방법의 유효성과 정확성을 알아보고자 하였다. 대상 및 방법 : 건강한 남성지원자 17명을 대상으로 CT와 3D Gradient dual echo 2-point DIXON 기법을 적용한 MRI를 이용하여 복부의 체적영상을 각각 획득하였다. 획득한 영상으로부터 2명의 관찰자가 독립적으로 내장지방과 피하지방의 경계를 구분하고 Region based thresholding 방법을 이용하여 전체지방용적(TATV), 내장지방용적(VATV), 피하지방용적(SATV)을 측정하였다. 측정된 값으로부터 관찰자에 따른 상관관계와 일치도 검증은 Spearman과 ICC test를 이용하였고, 영상방법 간 상관관계와 일치도 검증은 단순회귀분석과 Bland-Altman plot를 이용하여 검증하였다. p < 0.05인 경우에 통계적으로 유의하다고 판정하였다. 결 과 : 관찰자에 따른 측정값의 상관관계를 분석한 Spearman test 결과, CT와 MRI의 상관계수 R 값은 관찰자 1의 경우 TATV, VATV, SATV가 각각 0.995, 0.978, 0.968이고, 관찰자 2의 경우 0.968, 0.922, 0.956이었다. 관찰자에 따른 측정값은 통계적으로 매우 유의한 상관관계를 보였다(p<0.05). 관찰자 간 측정값의 일치도를 분석한 ICC test 결과, 관찰자 1, 2의 상관계수 R 값은 CT의 경우 TATV, VATV, SATV가 각각 0.990, 0.994, 0.983이고, MRI의 경우 0.978, 0.963, 0.987이었다. 관찰자 간 일치도는 통계적으로 매우 유의하였다(p<0.05). 영상방법에 따른 측정값의 상관관계를 평가한 단순회귀분석결과, 관찰자 1의 경우 TATV, VATV, SATV의 상관계수 R:결정계수 R2 값은 각각 0.997:0.994, 0.992:0.985, 0.980:0.960이고, 관찰자 2의 경우 0.975:0.950, 0.952:0.905, 0.970:0.941이었다. 두 영상방법 간의 상관 관계는 통계적으로 매우 유의하였다(p<0.05). Bland-Altman plot을 이용하여 두 영상 방법의 일치도 분석 결과, 관찰자 1, 2 모두에서 측정값의 차이는 거의 모든 대상자가 오차허용한계 범위(Mean ±1.96SD) 내에 있었다(p<0.05). 결 론 : 3D Gradient dual echo 2-point DIXON 기법을 이용한 MR 복부 지방용적측정 방법은 CT를 이용한 지방측정방법을 표준으로 비교하여서도 통계적으로 매우 강한 상관관계와 일치도를 보임에 따라 재현성과 정확성을 확인할 수 있었다. 이를 통하여 최근 사회적으로 관심이 집중 되고 있는 비만이나 대사증후군과 같은 질환의 관리와 평가에 보다 유용하고 정확한 임상정보를 제공 할 수 있을 것이라 생각한다.
        5,200원
        35.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The objective of this study is to evaluate the performance properties of chip seals and fog seals with polymer-modified emulsions. METHODS : The performance of chip seals and fog seals was evaluated on the basis of common issues in surface treatments. Granite aggregate and four types of asphalt emulsions (one of the unmodified and three of the modified emulsions) were used considering the usage in field. A Vialit test was performed to determine the aggregate retention, and the MMLS3 (Third Scale Model Mobile Load Simulator) test was conducted to determine the aggregate retention, bleeding, and rutting. In addition, the fog seal specimens were tested by the BPT (British Pendulum Test) to evaluate skid resistance. RESULTS AND CONCLUSIONS : Overall, the polymer-modified emulsions (PMEs) showed better aggregate retention and bleeding resistance for both chip seals and fog seals. When comparing the performance of the PMEs, the difference was not considerable. In addition, PMEs present significantly better rutting resistance than unmodified emulsions. For skid resistance, if the recommended mix design is applied, the specimens do not cause issues with skid resistance. Although all of the fog seal specimens were over the criteria for skid resistance, the specimen fabricated by the high emulsion application rate (EAR) of the unmodified emulsion was nearly equivalent to the skid value criteria. Therefore, the use of an unmodified emulsion with a high EAR should be carefully applied in the field.
        4,000원
        36.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 식품산업에서 큰 비중을 차지하고 있는 음료류에 대한 인공감미료 (삭카린나트륨, 아스파탐, 아세설팜 칼륨, 수크랄로스, 싸이클라메이트)의 함유현황 파악을 위한 동시분석법을 확립하였다. 희석 및 여과의 간편하고 효율적인 전처리 후 HPLC/MS/MS를 이용하여 5종 인공감 미료 동시분석 조건을 검토하였다. 컬럼은 C18(2.1 mm × 150 mm, 3.5 um), 이동상은 2% methanol (1 mM ammonium acetate)과 95% methanol (1 mM ammonium acetate)을 사용하여 농도구배 조건으로 각 성분을 분리하였으며 ESI/ SRM 방식으로 정량 분석하였다. 0.1~5.0 mg/L의 농도범 위에서 각 인공감미료 검량선은 1에 가까운 높은 직선성을 나타냈다. 검출한계, 정량한계는 각각 0.001~0.022 mg/ L, 0.004~0.073 mg/L로 저농도의 감미료 분석이 가능함을 확인하였다. 회수율은 92.76~113.50%, 정밀도는 10.91% 이하로 양호하였다. 이상의 결과로 본 분석법은 음료 중 인공감미료 분석에 적합하다고 판단되었다. 확립된 분석법으로 시중 유통 중인 음료 102건 분석한 결과 42건에 서 아스파탐, 아세설팜칼륨, 수크랄로스가 검출되었으며 삭카린나트륨과 싸이클라메이트는 검출되지 않았다. 검출된 인공감미료는 표시사항과 일치하였으며 사용대상과 사용량의 기준에 적합하였다.
        4,000원
        37.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 족관절 염좌 환자의 자기공명영상 검사 시 전하경비인대(AITFL)와 전거비인대(ATFL)를 관찰하기 위한 사방향 관상면(oblique coronal plane) 2D FSE 영상과 Isotropic 3D FSE Cube 영상의 비교를 통하여 그 유용성에 대하여 알아보고자 하였다. 대상 및 방법 : 2013년 10월부터 2013년 12월까지 족관절 염좌를 주 호소로 본 기관을 내원한 환자 15명(남자: 6명, 여자: 9명)을 대상으로, 사방향 관상면 2D FSE 기법과 시상면 3D FSE Cube 영상기법을 이용하여 AITFL과 ATFL의 영상을 획득하였다. 획득한 영상에서 AITFL과 ATFL, 골조직, 배경신호의 SI 및 CNR을 측정하고, Mann-Whitney U-검정으로 두 기법간의 통계적 유의성을 검증하여 정량적 평가를 하였다. 또한 영상의학의 2명이 각각의 영상에서 보여지는 AITFL과 ATFL의 형태 및 연속성, 부분용적에 의한 인공음영, 병변의 묘사정도의 3가지 항목을 4점 척도(0: 진단불가-Non diagnostic, 1: 부족함-Poor, 2: 적합함-Adequate, 3: 좋음-Good)로 평가하고, 평가결과 간의 일치도 검증을 위하여 Kappa-value(SPSS 19) 검정을 통해 통계적 유의성( p<0.05)을 검증하여 정성적 평가를 하였다. 영상획득에 사용된 장비는 3.0T MR 장비와 Extremity RF Coil을 사용하였다. 결 과 : 정량적 평가에서 CNR의 평균값은 AITFL의 경우 사방향 관상면 2D FSE영상에서는 10.72±0.01, 3D FSE Cube 영상에서는 18.66±0.52이었다. ATFL의 경우에는 사방향 관상면 2D FSE 영상에서는 5.62±0.98, 3D FSE Cube 영상에서는 8.15±0.65이었다. AITFL과 ATFL 모두 3D FSE Cube 영상에서 CNR 값이 높았으며, 두 영상기법 간의 CNR 값의 비교는 통계적으로 유의하였다( p<0.05). 정성적 평가에서 관찰자 1에 의한 AITFL의 형태 및 연속성, 부분용적에 의한 인공음영, 병변의 묘사정도의 평가결과는 사방향 관상면 2D FSE 영상의 경우 2.4±0.5, 2.5±0.5, 2.6±0.5의 순으로 값을 나타냈고, 3D FSE Cube 영상에서는 2.8±0.3, 2.9±0.2, 2.9±0.2의 순으로 값을 나타냈다. ATFL의 경우는 사방향 관상면 2D FSE 영상에서 2.5±0.5, 2.3±0.4, 2.5±0.5의 순으로 값을 나타냈고, 3D FSE Cube 영상에서는 2.8±0.4, 2.9±0.2, 2.9±0.2의 값을 나타냈다. 관찰자 2에 의한 AITFL의 형태 및 연속성, 부분용적에 의한 인공음영, 병변의 묘사정도의 평가결과는 사방향 관상면 2D FSE 영상의 경우 2.4±0.5, 2.3±0.8, 2.6±0.4의 순으로 값을 나타냈고, 3D FSE Cube 영상에서는 2.8±0.3, 2.8±0.3, 2.8±0.3의 값을 나타냈다. ATFL의 경우는 사방향 관상면 2D FSE 영상에서 2.8±0.4, 2.4±0.5, 2.8±0.5의 순으로 값을 나타냈고, 3D FSE Cube 영상에서는 2.9±0.2, 2.9±0.2, 2.9±0.2의 순으로 값을 나타냈다. AITFL과 ATFL 모두 3D FSE Cube 영상에서 평가 결과가 높게 나타났으며, 두 관찰자 간 평가결과의 일치도 검정은 통계적으로 유의하였다( p<0.05). 결 론 : 족관절 염좌 환자에서 3D FSE Cube 영상이 사방향 관상면 2D FSE 영상에 비해 AITFL과 ATFL의 손상 감별 및 기타 인대손상의 평가에 매우 유용하다는 것을 알 수 있었다
        4,800원
        38.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The objective of this study is to evaluate the curing and adhesive behavior of asphalt emulsions including polymer-modified emulsions for chip seals and fog seals. METHODS : For the laboratory testing, the evaporation test, the bitumen bond strength (BBS) test, and the Vialit test are used. Also, the rolling ball test and the damping test are employed to evaluate the curing properties of the fog seal emulsions. In order to conduct all the tests in controled condition, all test procedures are performed in the environmental chamber. The CRS-2L and the SBS CRS-2P emulsions are used as a polymer-modified emulsion, and then unmodified emulsion, the CRS-2, is compared for the evaluation of chip seal performance. For the fog seal performance evaluation, two types of polymer-modified emulsions (FPME-1 and FPME-2) and one of unmodified emulsion, the CSS-1H, are employed. All the tests are performed at different curing times and temperatures. RESULTS AND CONCLUSIONS : Overall, PMEs show better curing and adhesive behavior than non-PMEs regardless of treatments types. Especially, the curing and adhesive behavior of PMEs is much better than non-PMEs before 120 minutes of curing time. Since all the test results indicate that after 120 minutes of curing time the curing adhesive behavior of emulsions, the early curing time, i.e., 120 minutes, plays an important role in the performance of chip seals and fog seals.
        4,300원
        39.
        2014.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The objective of this study is to evaluate the bond strength of asphalt emulsions including polymer-modified emulsions for chip seals and fog seals using the bitumen bond strength (BBS) test. METHODS : For the laboratory testing, the Pneumatic Adhesion tensile Testing Instrument(PATTI) device is used to measure the bond strength between the asphalt emulsion and aggregate substrate based on the AASHTO TP-91. In order to conduct all the tests in controled condition, all test procedures are performed in the environmental chamber. The CRS-2L and the SBS CRS-2P emulsions are used as a polymermodified emulsion, and then unmodified emulsion, the CRS-2, is compared for the evaluation of chip seal performance. For the fog seal performance evaluation, two types of polymer-modified emulsions and one of unmodified emulsion, the CSS-1H, are employed. For chip seal study, the BBS tests are performed at 30, 60, 120, and 240 minutes of curing times with curing and testing temperatures of 15℃, 25℃, and 35℃. The fog seal tests are conducted at 30, 60, 90, 120, 180 minutes, and 24 hours with curing and testing temperatures of 25℃, 30℃, and 35℃. RESULTS AND CONCLUSIONS : Overall, chip seal emulsions and fog seal emulsions show the similar bond strength trend. At the same testing condition, polymer-modified emulsions show better bond strength than unmodified emulsions. Also, there is no significant difference between polymer-modified emulsions. One of important findings is that the most bond strength reaches their final bond strength within one hour of curing time. Therefore, the early curing time plays a vital role in the performance of chip seals and fog seals.
        4,000원
        40.
        2014.09 구독 인증기관·개인회원 무료
        최근 도로포장 건설은 신설보다는 현재 공용중인 도로포장을 확장하거나 유지보수를 하는 추세이다. 이에 따라 유지보수공법을 적용한 도로포장체에 대한 정확한 지지력 및 공용성 평가가 향후 도로포장의 수명 예측 및 유지보수공법 적용에 매우 중요한 요소가 되고 있다. 본 논문의 목적은 주기적인 유지보수 에 따른 도로포장의 층별 구조적 지지력을 정확하게 평가하기 위한 소형시편 동탄성계수 시험결과와 FWD 비파괴 시험 결과와의 상관관계를 규명하고자 한다. 현장 아스팔트 혼합물의 역학적 물성을 측정하기 위하여 소형시편을 이용한 일축직접인장 시험법을 이 용하여 아스팔트 층별 동탄성계수를 측정하였다. 노스캐롤라이나 주의 6개구간에서 구간별 3~5개 층, 2 개 지점에서 코어하여 소형시편을 채취하였다<그림 1>. 채취한 시편들은 5, 20, 40도에서 25, 10, 5, 1, 0.5, 0.1 Hz 하중조건에서 동탄성계수 시험을 수행하여 동탄성계수 마스터커브를 결정하였다. 본 연구에서는 도로포장층 탄성계수를 역산하기 위하여 유한요소 해석 아스팔트 포장 구조해석 프로그 램을 엔진으로 유전자 알고리즘을 활용한 역산 프로그램을 이용하였다. 본 프로그램은 한국건설기술연구 원에서 개발된 프로그램으로 노스캐롤라이나의 현장 및 실내시험 결과에 적용하였다. 도로포장층 FWD 역산 탄성계수는 아스팔트층의 경우, 탄성계수 범위가 1.5~6GPa이며, 보조기층 탄성계수 범위는 150~850MPa이며 노상층 탄성계수 범위는 60~400MPa이다. 도로포장체의 구조적 지지력은 아스팔트층 의 탄성계수와 두께에 의하여 결정된다. 실내시험을 통하여 결정된 동탄성계수에 두께를 곱한 후 합산한 값을 전체 아스팔트층 두께로 나눈 탄성계수 (Normalized Dynamic Modulus) 산정한 후 FWD 역산탄성 계수와 비교하였다. 본 탄성계수를 사용할 경우 도로포장의 두께의 영향을 고려할 수 있으며 두께가 지지 력 산정에 반영될 수 있다. <그림 2>에 나타난 바와 같이 역산과 실측 탄성계수간의 R square값이 0.73 으로 상관도가 매우 높음을 알 수 있다. 향후에는 FWD 하중 적용시 발생하는 아스팔트 각 층의 주파수 를 산정하여 주파수별 동탄성계수와 FWD 역산 탄성계수간의 상관관계를 검토하고자 한다.
        1 2 3 4 5