        21.
        2014.10 서비스 종료(열람 제한)
        In this study, a new type of the embedded column connection was proposed, and its flexural behavior was evaluated through a series of experimental study. Four full scale specimens for the proposed connections were constructed and tested. From the results, it was found that the flexural stiffness of the proposed connection was higher than that of the semi-rigid connection for all test specimens, and 200mm of embedment length was proper for the given test specimens in this study.
        22.
        2014.10 서비스 종료(열람 제한)
        The purpose of this study is to propose structural technologies on the light-weight composite floor systems in the unit modular and to evaluate fire resistance of the composite floor through standard fire test. The result of an experiment, we know that the proposed floor satisfied in 1 hour fire resistance time.
        23.
        2014.10 서비스 종료(열람 제한)
        The SPC wall girder is connected to the vertical walls to enhance performance of wall-wall girder connection. The purpose of this study is to investigate the structural characteristics such as strength, Load-displacement relation of wall-wall girder connection under the monotonic load tests. The fracture pattern of the specimens induced positive moment at connection was steel plate separation from concrete in SPC Wall.
        24.
        2014.10 서비스 종료(열람 제한)
        This study aims at understanding of the importance of modeling boundary conditions for connections of modules in 12-story modular building. The peak roof drifts under fixed condition and pinned condition are compared at design intensity levels in this paper.
        25.
        2014.04 서비스 종료(열람 제한)
        This paper is a aim to develop a connection modular-to-foundation that can be adapted using steel-frame middle & high-rise of the modular units. Analysis results, embedded column length is somewhat greater stiffness and strength were highly appreciated. Reduced embedded length even if the length of the base is not a problem for ensuring highly fixed.
        26.
        2014.04 서비스 종료(열람 제한)
        The SPC wall girder is connected to the vertical walls to enhance performance of wall-wall girder connection. The purpose of this study is to investigate the structural characteristics such as strength, Load-displacement relation of wall-wall girder connection under the cyclic load tests. The fracture pattern of the specimens was steel plate separation from concrete in SPC Wall induction of tensile crack failure of SPC Wall concrete.
        27.
        2014.04 서비스 종료(열람 제한)
        The SPC wall girder is connected to the vertical SPC walls to enhance performance of wall-wall girder connection. The fracture pattern of the SPC wall-wall girder connection was steel plate separation from concrete in SPC Wall. The purpose of this study is to theoretical analysis on fracture behavior of the SPC wall-wall girder connection under the monotonic load test inducing positive moment at connection. The Plastic hinge theory on steel plate of SPC wall girder is proposed to explain steel plate separation fracture pattern.
        28.
        2014.04 서비스 종료(열람 제한)
        In this paper, the dry solution for restraining the buckling failure of steel brace with the semicircle springs is presented. Finite element analysis shows that the effects of restraining the bucking of brace can be achieved if the structure of semicircle springs is designed appropriately.
        29.
        2014.04 서비스 종료(열람 제한)
        In this Study, lateral load resistance system is proposed to apply 12 story modular buildings to which X and inverted-V bracing is applied. The purposed system is analytically evaluated to determine the feasibility. As results, the inverted-V bracing is best suited for core system of 12 story modular building.
        30.
        2014.04 서비스 종료(열람 제한)
        To strengthen the competitiveness of the domestic precast concrete industry, any legal or institutional measures for a guarantee of quality and safety standards are required. So, the overseas cases for precast concrete certification program were investigated and analyzed to present the new certification program in Korea.
        31.
        2012.11 서비스 종료(열람 제한)
        The purpose of this study is to develop structral technologies on the lightweight composite slab systems with sound reduction layers in the modular house. In this study, two kinds of slabs with minimum thickness was suggested reducing the floor impact sound. In order to evaluate the structural performance, the flexural strenth tests were carried out on the one-way full scale specimens. From the results of test, we know that the proposed slabs had ductile behavior and would be safe sufficiently.
        32.
        2011.11 KCI 등재 서비스 종료(열람 제한)
        본 연구는 PC와 RC부분이 만나는 접합면에 대한 구조적 거동과 수평 전단강도 평가를 위한 실험적 연구이다. 접합면에서의 수평전단 내력은 접합면의 거칠기나 전단보강근 유무에 따라 결정되어진다. 본 연구에서는 전단 보강근의 형상이 루프형과 래티스형로 구분하고, 보강근 간격 등에 따라 총 4개의 수평전단강도 실험체를 제작하여 실험을 수행하였다. 실험결과, 접합면에서 수평전단 강도는 수직방향 변형에 의해 지배됨을 알 수 있었다. 보강근 형상에 따른 비교 결과, 루프형의 실험체가 평균 초기균열하중, 평균 최대하중 및 접합면의 평균 초기강성 측면에서 각각 33.7%, 45.9%와 55.2%정도 큰 것으로 나타났다. 현행의 국내 전단강도 평가식과 비교한 결과, 루프형 전단보강 실험체는 2.32∼4.23배, 래티스형 전단보강 실험체는 1.65∼3.06배 상회하는 것으로 나타났다. 따라서 접합면의 거동이나 구조설계기준에 의한 내력이 안전측으로 평가되어 현장에 적용하는 데에는 별다른 문제는 없는 것으로 판단된다.
        33.
        2011.01 KCI 등재 서비스 종료(열람 제한)
        기존의 철근 콘크리트 구조물에서 나타나는, 극한 환경하에서의 철근의 부식 문제 때문에 GFRP 보강근으로 철근을 대체하고 있다. 최근 들어 GFRP를 보강근으로 사용한 보의 성능에 대한 해석적, 실험적 연구가 지속적으로 행해지고 있지만 아직 철근 콘크리트 보의 연구에 대한 수에 비하여 이에 대한 연구 결과는 매우 적어 신뢰성을 얻기 힘든 상황이다. 이에 본 연구에서는 겹침이음된 GFRP 보강근을 보에 적용하여 모멘트-처짐 관계에 대한 실험적 연구를 수행하였다. 실험변수는 GFRP의 보강비와 피복 두께에 대한 것으로 총 6개의 GFRP 보강 콘크리트 보의 실험체가 제작되었다. 모든 실험체는4000mm의 스팬을 가지고 있으며 12.7mm의 지름을 가지는 GFRP 보강근을 사용하였다. 보강근이 겹침이음된 부분에 일정한모멘트가 작용하게 하기 위해 2점 가력 방식을 사용하였다. 실험 결과 보강근비의 증가에 따라 극한 하중의 크기가 증가하였다. 파괴 모드는 보강근비에 따라 매우 민감하게 변화하였으며 피복 두께는 인장측의 콘크리트의 탈락에 의해 최대 강도와 처짐량을 결정하는 요인이 되는 것으로 나타났다.
        34.
        2007.03 KCI 등재 서비스 종료(열람 제한)
        본 논문의 목적은 경량기포모르터를 충전한 스틸스터드와 복합스터드 내력벽체의 내화성능을 KS규준에 따라 평가하는데 있다. 주거용과 상업용 건물의 최소 내화 요구시간은 2시간이다. 시험 결과로부터 스틸 스터드와 복합스터드에 경량기포 모르터를 충전한 두 시험체 모두 2시간 내화 성능을 만족하는 것으로 나타났다. 또한 복합스터드 패널 시험체의 경우 내화 성능면에서 스틸 스터드 패널 시험체 보다 우수하다는 것을 정량적 평가하였다.