검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 4

        1.
        2022.10 구독 인증기관·개인회원 무료
        In ROK, when designing a spent nuclear fuel (SNF) storage facility and cask, criticality safety analysis is performed assuming that the SNF is a fresh fuel in order to ensure conservatism. Storage and transportation capacity can be increased by more than 30% by applying the burnup credit, but it has not been applied to the management of SNF. On the other hand, currently in criticality safety analysis, average burnup value is applied to axial burnup profiles, and it is not conservative because burnup of the middle of SNF is greater than average value. Thus, measuring burnup of SNF with high accuracy contributes to the economics and safety of the management of SNF. In this paper, nondestructive burnup evaluation methods for SNF are reviewed in order to study how to measure burnup more accurately. Gamma ray spectrometry and neutron counting have been used as non-destructive burnup evaluation methods of SNF. Gamma spectrum analysis uses the ratio of Cs-134/Cs-137 or Eu-154/Cs-137. The ratio of Cs-134/Cs-137 is used to SNF with cooling time less than 20 years, and the ratio of Eu- 154/Cs-137 is used to SNF with cooling time more than 20 years due to their half-life. In spectrum analysis, detector sensors with high efficiency and energy resolution are needed to clarify each spectrum. High-purity germanium (HPGe) detector has high energy resolution. However, it is not suitable for the analysis of the SNF in the spent fuel pool because it requires separate cooling system and large volume. Thus, CdZnTe (CZT) detector, which has medium energy resolution, is used as a detector of gamma ray spectrometry for the analysis of the SNF in the spent fuel pool. Recently, LaBr3 detector has been commercialized. Although it is difficult to compare clearly due to different conditions such as detector volume and crystal size, LaBr3 detector showed better resolution than CZT in the entire energy region. Neutron counting method has a large error compared to gamma spectrometry because the neutron flux is lower than gamma ray, and neutron absorption reaction, induced fission, and pool environment have to be considered. Large quantity of gamma energy is deposited in the detector by the fission fragments near the SNF. Therefore, fission chambers, which have the highest insensitivity to gamma rays, must be used as neutron detector in order to avoid noise from gamma rays.