검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2012.03 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        After a visit by Peter Waddell from the University of Strathclyde, Glasgow, UK in 1991, Robert H. Koch launched a program at the University of Pennsylvania to build lightweight pneumatic membrane mirrors, initially for balloon flight observa\-tions where weight is at a premium. Mirror cells were fabricated from sizes 0.18 m to 1.77 m, and experiments conducted to characterize the mirror figure and stability. Most of the work stopped after Prof. Koch’s retirement in 1996 until 2006 when the authors expressed an interest in building an array of medium-aperture portable telescopes. The program re\-started in earnest at Gravic, Inc. in Malvern, PA in 2008 with Koch using his extensive observational astronomy experience to guide the fabrication of a fully operational 1.07 m membrane mirror telescope with an optical tube assembly weigh\-ing under 45 Kg. Residual wavefront aberrations remediation resulted in Koch and the authors investigating membrane tensioning techniques with different cell designs, active secondary wavefront correction, photometric algorithms for ab\-errated images, and the use of additional lightweight mirror substrates from the Alt-Az Initiative Group, such as foamed glass. The best result for the lightweight mirrors was a point spread function spot size of several arc seconds. A lightweight 1.6 m cast aluminum cell alt-az telescope was subsequently designed by Koch and the authors for prime focus use.
        2.
        2012.03 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        This report describes the inception, development and extensive use over 30 years of elliptical polarimeters at the Uni\-versity of Pennsylvania. The initial Mark I polarimeter design utilized oriented retarder plates and a calcite Foster-Clarke prism as the analyzer. The Mark I polarimeter was used on the Kitt Peak 0.9 m in 1969-70 to accomplish a survey of ap\-proximately 70 objects before the device was relocated to the 0.72 m reflector at the Flower and Cook Observatory. Suc\-cessive generations of automation and improvements included the early-80’s optical redesign to utilize a photoelastic modulated wave plate and an Ithaco lock-in amplifier–the photoelastic modulating polarimeter. The final design in 2000 concluded with a fully remote operable device. The legacy of the polarimetric programs includes studies of close binaries, pulsating hot stars, and luminous late-type variables.