검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 3

        1.
        2023.11 구독 인증기관·개인회원 무료
        According to acceptance of radioactive waste, homogeneous waste such as concentrated liquid waste and spent resin must be solidified to reduce radiological hazards and protect public health and the ecology. However, when using a High Integrity Containers (HIC), it is stated that homogeneous waste can be disposed of without applying the solidification test requirements. PCHIC, developed in korea, is composed of polyethylene (PE, interior), polymer concrete (PC, filler), and steel (external reinforcement). Currently, PC-HIC will be used as a packaging container for low-level liquid waste and spent resin waste. PE has a lower shielding efficiency compared to PC, but it offers the economic advantage of lower production costs. Therefore, cost savings can be expected if very low-level waste is packaged and disposed of HIC made only of PE materials (PEHIC). Despite the economical advantage of PE-HIC, PE-HIC has not been used domestically since NRC (Nuclear Regulatory Commission) reported that PE-HIC couldn’t meet the mechanical integrity criteria for radiation exsure. However, according to IAEA (International Atomic Energy Agency) research, it has been reported that mechanical integrity of PE-HIC is not affected when the absorbed dose is below 50 kGy. Therefore, in this study, Radiological impact of VLLW packaged into PE-HIC is evaluated to confirm that the absorbed dose is below 50 kGy, which then be used to assess feasibility of PE-HIC to be used as packaging and disposal container for radioactive waste. Radiological impact of VLLW packaged into PE-HIC is evaluated to confirm that the absorbed dose is below 50 kGy, which then be used to assess feasibility of PE-HIC to be used as packaging and disposal container for radioactive waste. The feasibility of using PE-HIC as packaging-disposal containers for radioactive waste will be reviewed. In this study, the radiation effects of only waste packaged in PE-HIC were considered, and additional assumptions are as follows. - Nuclides subject to radioactivity evaluation: Co-60, Cs-137 - Radioactivity concentration: very low-level radioactive wastel concentration limit - Target waste: waste resin - PE-HIC dimensions: outer diameter: 1,194 mm, height: 1,290 mm, and thickness 88 mm (PCHIC internal PE shape) Considering the above assumption, the exposure rate was evaluated using the MicroShield program. Since the density of PE-HIC in the MicroShield program was assumed as the density of air. The absorbed dose was recalculated through density correction of the derived exposure rate. As a result, it was confirmed that absorbed dose was about 2-3 mGy over 300 years. As a result of dose evaluation by MicroShield, it is judged that the mechanical integrity of PEHIC as an packaging of VLLW can be proved by confirming that the absorption dose irradiated to PE-HIC by internal waste is less than 50 kGy.
        2.
        2010.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 Ogre3D 렌더링 엔진을 사용한 3D게임 개발의 쉬운 접근방법을 시도해보고자 하였다. 일반적인 게임 개발 프로세스는 DirectX를 사용해 렌더링 엔진을 만들고 이를 사용해 게임을 만들어 개발기간이 오래 걸리고 어렵다 는 단점이 있다. 따라서 본 논문에서는 이러한 단점을 극복하고자 공개 렌더링 엔진인 Ogre3D를 사용하였고 이에 따른 개발시간의 단축과 간결한 코드의 사용으로 렌더링 결과를 쉽게 확인할 수 있는 과정을 설명하고자 한다.
        4,000원
        3.
        2019.10 KCI 등재 서비스 종료(열람 제한)
        This study examined the port expansion plan for the fishery port at the east coast of Korea, in accordance with permission conditions for coastal ports such as a limit on the cargo volume and passenger demand for the coastal tourism belt formation. The site was chosen as a municipal coastal port attracting the new ocean industry and building waterfront zone as a hub of new marine tourism. Two different numerical models (Swan and Bouss 2D) were used. Before applying to the target sea area, some numerical tests were conducted for the variation according to Bouss-2D's strong/weak and nonlinear technique compared to the irregular diffraction of semi-infinite breakwater with a theoretical solution. As a result, there was a difference in strong nonlinearity with breaking waves and it was necessary to experiment with a strong nonlinear analysis technique for the actual site. Two numerical models were applied to the fishery port site and the tranquility of some alternatives were analyzed. The numerical results show the most suitable plan was ALT-1, with satisfied harbor tranquility and reasonable economic sense. The extension of the east breakwater and enlarged turning basin of the F-Land plan have brought generally more stable harbor tranquility than the ALT-1. The result can be used as a reference for the port expansion plan in the future.