Outdoor storage fires have a significant impact on the surrounding environment, including adjacent storage facilities and buildings. Therefore, it is essential to review and manage the fire impact to minimize damage to human life and property on the outdoor storage fires. In this study, the heat release rate and radiant heat flux were simulated according to the fire time, wind veolcity, and presence or absence of water spray equipment in an outdoor storage facility fire, and the fire impact was analyzed. The outdoor storage was designed to simulate two scenarios on the outdoor storage fires containing gasoline, and FDS was used for fire simulation. As a results, when the water spray facility was not operating and the wind velocity was 5 m/s, the maximum radiant heat flux was 24.80 kW/m2, which exceeded the limit radiant heat flux of 20 kW/m2. When the water spray facility was operating and the wind veolcity was 10 m/s, the maximum radiant heat flux was 18.77 kW/m2, which did not exceed the limit radiant heat flux, indicating that the fire impact on adjacent storage facilities was relatively small.
In recent years, the number of cases caused by people such as forest fires has been increasing, so it is very important for the whole nation to prevent and practice forest fires. In addition, due to climate change around the world, many lives and disaster losses are increasing due to forest fire-related disasters, and in the last 10 years (2014-2023), there have been 5,668 forest fires and 40,037 hectares of damage, which is equivalent to 56,000 football fields, resulting in 19 casualties and 285.4 billion won in damages. Now, in order to improve the understanding and awareness of forest fires among all the people, the government should actively inform the people about how to act in the event of a forest fire by making the people's action tips related to forest fires easy to understand and practical through public relations activities. In addition, the public and the government should work together to prevent and prepare for forest fires before they occur.
In modern society, buildings are becoming more complex, and the population is becoming more densely populated. Such large buildings require a variety of evacuation measures, as there is a high possibility of large-scale human casualties due to increased evacuation distance and evacuation time in the event of a fire. Strobe light and exit sign light are used as important evacuation equipment to provide early warning and evacuation directions. In this thesis, we conducted a fire simulation assuming that a fire occurrence point notification function and a strobe light function were added to equipment such as visual alarms and evacuation guidance, and compared and analyzed the difference in evacuation completion time with existing equipment. The scenarios for the simulation were divided into “general fire situations” and “fire location and evacuation exit guidance situation” and the differences in evacuation completion time in the event of a fire were compared and analyzed for each floor from the 1st floor to the 3rd floor. The maximum travel distance to complete evacuation in the case of a fire on the first floor decreased by 80.6 m and the evacuation completion time decreased by 329.4 seconds, and the maximum travel distance to complete evacuation in the case of a second-floor fire decreased by 28.5 m and the evacuation completion time by 438.8 seconds. During the fire on the third floor, the maximum distance decreased until evacuation was completed to 3.4 m, and the evacuation completion time was reduced by 355.6 seconds. It is expected that if the congestion level of evacuation routes is reduced by utilizing the congestion level of evacuation exits when fire alarm systems and evacuation equipment are activated, the evacuation completion time will be further shortened and evacuations will be carried out quickly and safely.
This study aims to propose an improvement of fire safety management plans for buildings, such as apartment complexes and schools, within a 10 km radius of industrial complexes. It utilizes an off-site consequence analysis program to reflect the toxic impact on national industrial complexes and surrounding areas. The ALOHA program was utilized to analyze the impact of toxicity due to a hydrogen chloride leak, a hazardous material. The results showed that the area with AEGL-2 and above ranged from 3.1 km to 10 km, the AEGL-3 area ranged from 1.9 km to 7.3 km. The ASET was measured to be between 3 and 24 minutes. Due to the impact of toxicity, it is necessary to prepare fire safety management plans for buildings, such as apartment complexes and schools that are within a 10 km radius from industrial complexes. These safety plans incorporate the hydrogen chloride risk assessment results, ASET, weather conditions, and coordination with the local community.
고주파 흡수제(Accusorb MRI)를 이용한 자기공명영상 검사 중 화재가 발생했다. 다행히 환자는 화상을 입지는 않았 지만 스트랩과 4채널 코일의 케이블, Accusorb MRI가 녹아서 탄 흔적이 발견되었다. 자기공명영상 검사에 사용되 는 도구의 안전 지침을 준수해야 하지만 이를 지키지 않으면 화상, 열상, 장비 손상의 위험이 있다. 사고를 방지하기 위해서는 철저한 사전 점검을 해야 하고 모든 기기, 물품들이 자기공명영상 검사 시 사용 가능한 제품인지 확인하고 사용법을 정확하게 숙지하여야 한다.
STCW 협약 A-VI에 의거, 승선 필수 증서를 발급받기 위해 소화 과정 최저 훈련 이수를 거치게 되는 공간이 수소화 훈련장 이다. 선박 화재의 상황과 유사한 장소에서 발생한 화재 진압 훈련을 위한 실습 장소의 특성상, 재실자의 안전을 보장할 수 있는 운영 을 위해 안전성을 수치화하여 평가하고 기준을 수립하는 연구의 필요성이 대두되었다. 화재 안전 평가를 위해 FDS를 기반으로 한 Pyrosim을 활용하여 제연설비 유무에 따른 Case를 설정, vector의 분석을 통한 연기 유동 및 열기에 대한 평가를 수행하였다. 피난 안전 평가는 Pathfinder를 통해 허용 피난시간, 총 피난시간을 수치화된 결과로 해석, 비교하여 안전성을 분석하였다. 각 Case에 대한 안전성 을 평가함으로 제연설비별 기능의 적정성을 수치, 시각적으로 나타내었으며, 현재 운영 상태는 안전성이 양호한 것으로 평가하였다. 집 진설비가 정지한 비상상황은 각 피난시간과 111.2초의 여유시간으로 나타내어 수소화 훈련장의 비상상황에 대한 피난시간의 기준으로 활용할 것을 제시하였다.
지형적인 이질성이 심한 강원도, 경상북도에 집중되고 있는 대형 산불을 관리하기 위해서는 위성 영상을 활용하여 효율적이고 신속한 피해 평가를 통한 의사 결정 과정이 필수적이다. 이에 본 연구는 2022년 3월 5일에 강원도 강릉 및 동해에서 발화하여 3월 8일 19시경 진화된 대형 산불을 대상으로, dNBR을 활용한 산불 심각도 산정과 등급에 영향을 미치는 환경요인을 도출하고자 하였다. 환경요인으로는 식생 또는 연료 유형을 대표하는 정규식생지수, 수종을 구분한 임상도, 수분함양을 나타내는 정규수분지수, 지형과 관련해서는 DEM 등을 수치화한 후 산불 심각도와의 상관 관계를 분석하였다. 산불 심각도는 산불 피해 없음(Unbured)이 52.4%로 가장 넓었고, 심각도 낮음 42.9%, 심각도 보통-낮음 4.3%, 심각도 보통-높음 0.4% 순이었다. 환경요인의 경우 dNDVI, dNDWI와는 음의 상관관계를, 경사도와 는 양의 상관관계를 나타내었다. 식생과 관련해서는 산불 심각도에 영향을 미치는 것으로 분석된 dNDVI, dNDWI, 경사도 모두에서 침엽수, 활엽수, 기타의 집단간 차이가 p-value < 2.2e-16로 유의미한 것으로 분석되었다. 특히, 침엽수 와 활엽수의 차이가 명확하였는데, 강원도 지역에서 우점종인 소나무를 비롯하여 잣나무, 리기다소나무, 곰솔 등의 산불 심각도가 높아 침엽수가 활엽수에 비해 피해를 받는 것이 확인되었다.
최근 원자력 지진 PSA(Probabilistic Safety Assessment)를 토대로 산업시설물의 지진 PSA를 수행하는 연구가 진행되었다. 해당 연 구는 원자력 발전소와 산업시설물의 차이를 파악하고, 최종적으로 운영정지를 목표로 하는 고장수목(Fault Tree)를 구축한 후 시각적 확률도구인 베이지안 네트워크(Bayesian Network, BN)으로 변환하였다. 본 연구는 선행연구를 기반으로 지진으로 유발된 구조손상 으로 인해 발생 가능한 화재・폭발에 대해 PSA를 수행하고자 하였다. 이를 위해 화재・폭발을 사건수목(Event Tree)으로 표현하고, BN 으로 변환하였다. 변환된 BN은 화재・폭발 모듈로서 선행연구에서 제시된 고장수목 기반 BN과 연계되어 최종적으로 지진 유발 화재・ 폭발 PSA를 수행할 수 있는 BN 기반 방법론이 개발되었다. 개발된 BN을 검증하기위해 수치예제로서 가상의 가스플랜트 Plot Plan을 생성하였고, 가스플랜트의 설비 종류가 구체적으로 반영된 대규모 BN을 구축하였다. 해당 BN을 이용하여 지진 규모에 따른 전체시 스템의 운영정지 확률 및 하위시스템들의 고장확률 산정과 더불어 역으로 전체시스템이 운영 정지되었을 때 하위시스템들의 영향도 분석과 화재・폭발 가능성을 산정하여 다양한 의사결정을 수행할 수 있음을 제시함으로써 그 우수성을 확인하였다.
2000년 삼척산불지역의 복원유형별 식생구조와 종다양도를 파악하여 복원의 효과를 정략적으로 평가하고자 영구조사지를 대상으로 매목조사와 군집분류를 수행하였다. 조사구 26개소를 대상으로 이원지표종분석(TWINSPAN)과 DCA분석을 통해 분류한 결과, 소나무 군집(군집Ⅰ), 신갈나무 군집(군집 Ⅱ) 및 굴참나무 군집(군집 Ⅲ)으로 분류되었다. 군집별 상대우점치 분석 결과, 군집 I은 혼효림으로서 천이가 예상되며, 군집 II는 신갈나무 군집으로 군집 Ⅲ은 굴참나무 군집을 유지할 것으로 예상된다. 군집 간 유사도지수는 49.46% ∼ 70.69%이며, 종다양도지수는 1.5441 ∼ 1.7924로 나타났다. 인공복원지와 자연복원지(잔족목 제외)간 생장은 거의 유사한 편이나, 굴참나무의 경우 수고는 자연복원에서 직경은 인공복원에서 생장이 원활한 것을 확인하였다. 자연복원과 인공복원간의 생장의 큰 차이를 보이지 않으므로, 종자재생과 맹아재생간의 경쟁을 통한 자연복원과 지속적 관리를 통한 인공복원 중 대상지에 적합한 복원 방향을 설정하는 것이 바람직할 것으로 판단된다.
As the distribution of vehicles and logistics increases due to the development of human civilization and the increase in population, various roads play an important role in domestic traffic and transportation. However, the recent emergence of large cities and new cities is causing traffic problems, and the increase in roads is inevitable for the smooth distribution of vehicles and logistics. In Korea, mountainous regions occupy 70% of the country, so tunnels are used to open roads. Without this, it is difficult to open the road. Currently, there are 3,720tunnels (as of December 31, 2023) installed on high-speed national highways, general national highways, and local roads nationwide, with a length of 2.499 and increasing every year. Accordingly, fire accidents in tunnels will also increase, and due to the nature of tunnel fire accidents, there is a high probability that they will escalate into large-scale disasters, resulting in casualties and property damage, as well as significant social losses due to the disruption of logistics transportation, etc. As the possibility of potential hazards is increasing, the purpose of this study is to build a safe and efficient tunnel system by optimizing maintenance and management for fire and disaster accidents in tunnels.
국토 대부분인 산지로 구성된 국내의 특성상 대형 산불 사례가 지속적으로 보고되고 있으며, 동해안에서 다발적으로 발생하 는 과거 대비 최근 서해안의 산림원이 확대됨에 따라 점차 전국화되고 있는 실정이다. 본 연구에서는 이러한 산불 발생 주기의 증가로 인한 산지에 설치되어 있는 사방댐의 산불에 의한 영향성 평가를 수행하였다. 대상 구조물은 선행 연구에서 사용된 강재, GFRP 및 CFRP를 사용한 투과형 사방댐으로 선정하였으며, 각 재료별 구조재를 사용한 투과형 사방댐의 안전성 평가를 위해 상용 유한요소해석 프로그램인 ABAQUS를 활용하였다. 해석 결과, 600℃ 수준에서 파괴가 발생한 강재 구조재에 반해 FRP 구조재는 800℃ 이상에도 파 괴되지 않음을 확인하였다. 또한, FRP 구조재는 강재 대비 10.30%∼11.20% 가량 낮은 응력 수준을 보였으며, 최대 변위는 약 73.1배, 17.9배 증가하는 것으로 측정되었다. 콘크리트로 구성된 댐체의 경우, 구조재의 설치부에 응력이 집중됨을 알 수 있으며, 압축 측은 모 든 구조재에서 안전한 것으로 나타났지만, 인장 측은 600℃ 이상에서 모든 구조재의 댐체 콘크리트가 파괴됨을 확인하였다. 따라서, 사 방댐 설계 시 이러한 강도 감소를 충분히 고려할 필요가 있을 것으로 사료된다. 댐체와 구조재가 연결되는 고정부의 경우, GFRP 및 CFRP 구조재가 강재 구조재 대비 약 82.43%, 67.63% 감소된 반력을 보이는 것으로 확인되었다. 이러한 결과는 FRP 구조재의 높은 변위가 하중을 소산하여 고정부에 적은 영향을 미치는 것으로 생각된다. 결론적으로, FRP 구조재를 사용하는 것은 기존 강재 구조재 대비 고온 저항성 측면에서 다양한 이점을 얻을 수 있으나, 수치해석적 접근법으로 평가된 결과이므로 향후 지속적인 연구로 신뢰성을 검증할 필요가 있다.
This study uses a frequency analyzer to measure and analyze the major alarm sounds of cars selected by domestic car manufacturer and car size, which are continuously improving in accordance with the continuous development of the automobile field. Therefore, the purpose is to find the alarm sound that modern people can hear best and find improvement measures accordingly. In the past, only the driving performance of vehicles was considered important, but as the industry and science developed, research was conducted to satisfy not only the driving performance of vehicles but also the comfort and emotional needs of drivers, such as ride comfort, safety, and noise issues. At the same time, it is progressing actively and continues to develop.
PURPOSES : This study focuses on how quickly emergency alarm facilities recognize a fire, respond to evacuation behavior, and induce appropriate behavior in response to the fire alarm sound by listening to the fire alarm sound from a sound device. METHODS : Prior research on alarm sounds affecting evacuation behavior was identified, and a subjective evaluation of alarm sounds was conducted to study the most appropriate evacuation-inducing behavior for alarm sounds. In the event of a fire, a subjective evaluation of the sound pressure level and frequency analysis of the sound system, which affects the occupants in the building, were conducted to analyze the type of alarm sound and evacuation behavior. RESULTS : As a result of the subjective evaluation of the occupants’ listening risk, there was little cognitive response to the change in sound pressure level according to frequency. It was found that the alarm sound could give a sense of crisis or tension owing to the difference in sound pressure level change according to the change in time difference. CONCLUSIONS : In conclusion, with high sound pressure and large decibel deviation, the evacuation behavior of respondents after education was more active in the wake-up call that made a sound that seemed to be torn.
PURPOSES : This study is conducted to evaluate the development of materials for extinguishing ESS(Energy Storage System) fires in electric vehicles using industrial byproducts. METHODS : Grout containing an appropriate amount of fly ash, silica fume, blast furnace slag powder, and ferronikel slag, which are industrial byproducts, was prepared. The fluidity, stress, and mechanical properties were evaluated in accordance with standard test methods. RESULTS : The fluidity of the materials used for the evolution of ESS fires differed depending on the material of the industrial byproducts. In the case of blast furnace slag, its fluidity is low owing to viscosity even when it content is high, and the use of ferronikelsrag is shown to be suitable for the evolution of ESS fires in fluidity and curing tests. CONCLUSIONS : Fire-extinguishing materials using industrial byproducts require a long curing time but exhibit the fluidity required for ESS fire extinguishment. In particular, the curing and fluidity of Peronikel slag and fly ash are suitable for ESS fire extinguishing.
건축물은 사용자의 부주의, 전기적, 기계적 요인 등에 의해 화재가 발생할 수 있고, 화재 발생 시 각 재료의 특성에 따라 강성 및 강도가 감소하여 구조 성능이 저하될 수 있다. 이러한 상황에서 적절 한 성능 복구가 되지 않으면 후에 지진 등의 큰 하중이 가해질 때 건축물 붕괴 등 치명적인 피해가 발생할 수 있다. 현재 내화성능을 높이는 방법으로 내화피복을 사용하는 등 수동적인 방법에 머물러 있으며, 꾸준한 유지관리 등이 필요하다는 단점이 있다. 따라서 변형 후 열을 가하면 원래의 형상으로 돌아가는 성질을 가진 형상기억합금을 사용하여 콘크리트 보를 보강하고, 화재 시, 화재 후에 프리스 트레스트 콘크리트와 유사한 방식으로 콘크리트에 압축응력을 발생시켜 구조 성능을 향상시킬 수 있 는지 ANSYS 구조해석 프로그램을 통해 그 효과를 확인해보고자 한다.
In this paper, as there are many cases of fires occurring due to the failure or inoperability of the thermostat of electronic products, the purpose is to test and analyze the risks and probabilities through fire cases and reproduction experiments, and suggest countermeasures. Among electronic products, water purifiers are composed of a refrigerant system with a compressor to make cold water, a heating device to make hot water, and an electric device used as an energy source. Due to the nature of the water purifier manufacturing, these devices are subject to a lot of moisture and dust. etc. exist in large quantities and use electrical energy, so there is a possibility of fire due to short circuit in the wire, electrical abnormal overheating (tracking phenomenon) in the thermostat, electronic board, starting relay, etc., and overheating of the heating device (Band Heater). there is. Therefore, in order to prevent fires from these devices, a system to remove foreign substances inside the water purifier is necessary, the use of heat-resistant (fire-resistant) wires for electrical devices is essential, and the use of non-combustible materials (semi-combustible materials) for each part is necessary to prevent fire. The risk must be eliminated through prevention and combustion expansion prevention devices.