검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 490

        181.
        2012.04 구독 인증기관 무료, 개인회원 유료
        The existing study on fiber reinforced of the reinforced concrete columns are mainly used to thermosetting resin for evaluate the seismic performance. as compared with thermoplastic resin, thermosetting resin is the advantage of greater strength and stand in high temperature. but, thermosetting resin has many environmental problems about recycling. In this study, better toughness, recyclability and the advantage of rapid construction than thermosetting resin used to the seismic performance evaluation. The existing unreinforced and Superex reinforced concrete compression test specimens experimented with 4 kinds about reinforced repeat. (unreinforced, 1 layer, 3 layers, 5 layers) The test results appear to be increased the maximum load of 98.37% that 5 layers reinforced repeat when compared to unreinforced
        3,000원
        182.
        2011.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Two-dimensional (2D) nano patterns including a two-dimensional Bravais lattice were fabricated by laser interference lithography using a two step exposure process. After the first exposure, the substrate itself was rotated by a certain angle, 90˚ for a square or rectangular lattice, 75˚ for an oblique lattice, and 60˚ for a hexagonal lattice, and the 90˚ and laser incident angle changed for rectangular and the 45˚ and laser incident angle changed for a centered rectangular; we then carried out a second exposure process to form 2D bravais lattices. The band structure of five different 2D nano patterns was simulated by a beam propagation program. The presence of the band-gap effect was shown in an oblique and hexagonal structure. The oblique latticed ZnO nano-photonic crystal array had a pseudo-bandgap at a frequency of 0.337-0.375, 0.575-0.596 and 0.858-0.870. The hexagonal latticed ZnO nano-crystallite array had a pseudo-bandgap at a frequency of 0.335-0.384 and 0.585-0.645. The ZnO nano structure with an oblique and hexagonal structure was grown through the patterned opening window area by a hydrothermal method. The morphology of 2D nano patterns and ZnO nano structures were investigated by atomic force microscopy and scanning electron microscopy. The diameter of the opening window was approximately 250 nm. The height and width of ZnO nano-photonic crystals were 380 nm and 250 nm, respectively.
        4,000원
        183.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        유리강회플라스틱(GRP)은 재료의 자중에 비해 아주 높은 강도를 가지고 있다. 또한 부재의 두께에 따라서 투명 혹은 반투명의 효과를 거둘 수 있다. 하지만 Hand laminating의 특성상 일률적인 재료의 강도를 선뢰하기 어렵기 때문에 구조 계산 혹은 설계 시 반드시 재료 실험을 수행하여야한다. 본 논문은 두께 4mm, 높이 30m의 의장적 기둥을 구조적으로 설계하기 위한 재료 실험을 수행하였다. 또한 실험 결과에 대한 평가를 통해 DIN에서 규정하는 재료적인 강도와 비교 분석하였다. 이를 통해 규준에서 제시하는 값과의 차이를 확인했으며 실제 설계에 반영하기 위해 반드시 재료실험이 수행되어야함을 알 수 있다.
        4,000원
        184.
        2011.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 대상은 1-2W 기본형 온실의 기둥을 절단하여 동일한 규격의 파이프로 용접하여 온실의 측 고를 높인 온실이다. 이와 같이 개조형 온실에 풍하중이나 적설하중이 작용할 경우, 어떠한 형태로든 용 접부위에는 구조적으로 불안전 할 것으로 판단된다. 이를 검토학기 위하여 4단계에 걸쳐 용접된 기둥에 대한 굽힘 강도를 측정하여 용접하지 않은 원상태의 파이프와 비교 검토한 결과는 다음과 같다. 온실구조용 강관에 대한 용접결합부의 굽힘 시험의 경우, 하중재하 방법에 관계없이 양단 지점부위와 하중 재하부위가 하중을 견디지 못하고 함몰되는 현상을 보임으로서 합리적인 결과를 도출할 수가 없었 다. 따라서 지점 및 하중 재하부위에 내부 파이프 (봉강)을 삽입함으로서 부분적인 문제점을 보완할 수 있었지만, 보다 합리적인 굽힘 시험 방법이 고안되어야 할 것으로 판단되었다. 용접결합부의 강도는 원형 상태에 비해 별 차이를 보이지 않았고, 시료의 제작 조건에 따라 경미한 차이를 보였으나, 용접 과정에서 부실의 정도가 결정적인 강도 손실을 유발할 수 있음이 예상되었다. 용접결합과정의 문제점이나 접합 작 업 후, 기둥 부재의 기울어짐 등에 대한 문제점이 없다는 전제 하에 용접한 파이프의 강도는 일반적으로 원형상태의 강도에 비해 약 84~90% 정도로 가정함이 합리적일 것으로 판단되었다. 그리고 접합부의 녹 발생이나 기타 용접결합에 따른 중장기적 강도 저하 등을 고려할 때, 부득이한 경우가 아니라면 현재 농 가에서 시도되고 있는 온실의 주요 부재에 대한 구조변경 등은 구조안전성 측면에서 지극히 삼가 되어야 할 것으로 판단되었다.
        4,000원
        185.
        2011.04 구독 인증기관·개인회원 무료
        In this study, We evaluated structural performance of SRC Column using square steel tube. the parameter is a pre-axial load for inner CFT column. ABAQUS 6.9.3 was used for analysis. The results from this study show that the pre-axial load for inner CFT column does not affect to structural performance of the SRC column using square steel tube. And, a experimental test is needed to investigate the results of this study.
        186.
        2011.04 구독 인증기관·개인회원 무료
        The Axial compression tests were conducted on FRP strengthened circular CFT short clumns with the test parameters of D/t ratio and the number of FRP sheet ply. The ultimate strength design formula were proposed by applying ACI 440 code for FRP strengthened circular CFT columns.
        187.
        2011.04 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to deliberate on design application for a structure of beam with partially restrained composite connection to CFT column. It was intended to apply an economic and stable component by adjusting stiffness ratio of column connection through partially restrained composite connection. As a result of the review of stability of the structure, it was confirmed that in case of a low-rise building as a moment frame, it could be resisted without brace, as stiffness was increased when taking advantage of partial restrained composite connection by composite action.
        3,000원
        188.
        2011.04 구독 인증기관 무료, 개인회원 유료
        This study aimed at construction of text and graphic database for moment-rotation curves of partially restrained composite beam-to-column connections. key words The M-θ data or figures under monotonic or cyclic tests are made as text files. Also, Eurocode 3 classification is added to the M-θ curve to verify as semi-rigid connections. For structural analysis, linear rotational stiffeness or nonlinear M-θ curves are transformed three-parameter power model. Although this database has some limitation, it will be used for further PRCC researches and tests.
        3,000원
        189.
        2011.04 구독 인증기관 무료, 개인회원 유료
        The conventional RC flat plate slab system have many good features, which are design flexibilities, saving of story-height and economy of construction etc. But the study of flat plate slab system for H-steel or SRC column have been rare both at home and abroad. Main topics in this study is a new structural detail for connection between H-Steel or SRC column and flat plate slab. The test for lateral performance of connection between H-Steel or SRC column and flat plate slab was carried out. From the test results structural characteristics - yield moment, yield rotation, maximum moment, deformation capabilities and so on - are obtained and evaluated.
        3,000원
        190.
        2011.04 구독 인증기관·개인회원 무료
        The concrete filled steel tube (CFT) that shows an excellent performance can be more economically used when the steel tube has a large width-to-thickness ratio. However, national codes such as KBC or AISC limits the use of a plate with a large width-to-thickness ratio, resulting in exclusion of possibility of more effective use of CFT. The purpose of this study is to remove the limitations by applying the concept of effective area which can consider local buckling and post-buckling strength. As a starting point, the effective area concept used in pure hollow steel sections in the current codes are applied to composite CFT columns and the results indicates that the limitations can be successfully removed.
        191.
        2011.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 CFRP쉬트로 보강된 원형 CFT기둥의 압축거동을 관찰하고 설계식을 제안하였다. 원형 CFT기둥의 CFRP쉬트의 보강효과를 관찰하기 위해 10개의 실험체를 제작하여 중심축하중 실험을 수행하였다. 실험변수로는 CFRP쉬트 보강겹수와 직경-두께비(D/t)이다. 실험결과 원형CFT기둥에 CFRP쉬트 보강을 통해 압축내력을 증가시킨 것으로 나타났다. 끝으로 ACI 440code를 응용하여 CFRP 보강된 원형 CFT기둥의 압축내력을 예측하기 위한 설계식 을 제안한다. 제안식을 분석한 결과 실험결과와 비교적 일치한 것으로 나타났다.
        4,000원
        192.
        2011.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        FRP Sheet와 비좌굴가새를 적용한 보-기둥 접합부의 보강효과를 평가하기 위하여 보-기둥 접합부 실험체에 축력 및 반복 횡가력을 가하여 실험을 수행하였다. 동일한 크기의 6개의 실험체를 제작하였으며 FRP Sheet의 종류 및 비좌굴 가새의 유무를 변수로 하였다. 실험체의 파괴양상 및 최대하중, 연성지수, 에너지소산능력의 측면에서 실험결과를 분석하였다. 실험결과 CFRP Sheet와 비좌굴가새를 혼용한 보강방법이 가장 우수한 성능을 나타냈다.
        4,000원
        193.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 기존 철근콘크리트 구조물에 대하여 대표적인 변위-기반 설계법인 Chopra&Goel 이 제안한 직접변위-기반 설계법의 기본개념을 적용하여 최대 설계지반 가속도에 대한 보강 Steel Jacket의 두께를 결장하고, 결정된 보강 두께를 적용하여 보강전 후 성능설계기법에 의한 비선형 해석 및 보강설계법에 의한 보다 개선된 알고리즘 및 프로그램을 제시하였다. Steel Jacket 보강된 철근콘크리트 기둥에 대한 설계 변위 추정을 위해 Steel Jacket 보강된 철근콘크리트 부재의 비선형 층상화 세그멘트 해석 모델을 제시하고, 성능기반설계에 의한 성능개선설계를 위하여 목표성능변위 및 설계자전가속도 조건에 대해 직접 변위-기반 설계 방법 및 변위계 수법에 의한 내진성능개선 설계 방법을 제시하였다. 적용 예에서 본 방법은 기존 철근콘크리트 기둥과 비교하여 성능개선설계 결과 보강 전에 비해 변위 연성비 및 변위성능에서 크게 개선된 성능설계 결과를 제공해 주었다.
        4,000원
        195.
        2010.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        프리캐스트 콘크리트 골조에서 실물크기의 보-기둥 접합부 실험체 5개를 대상으로 반복가력 실험을 수행하였다. 지진하중을 받는 골조를 대상으로 1개의 일체식 실험체와 4개의 프리캐스트 실험체를 포함하여 5개의 1/2스케일의 내부 보-기둥 접합부를 대상으로 하였다.주요 변수는 보의 구조적 연속성을 확보하기 위한 접합부의 형태와 접합부의 특별한 보강형태(섬유콘크리트와 횡보강근)로 하였다. 실험체는 강기둥-약보 개념에 따라 설계하였다. 보 철근은 접합부에 큰 비탄성 전단력이 작용할 경우 보에 소성힌지가 발생하도록 계획하였다. 접합부의 성능평가는 접합부의 강도, 강성, 에너지 소산능력과 층간변위비로 평가하였다. 실험결과 실험체의 파괴는 보의 소성힌지부에서 파괴되었다. 보-기둥 접합부의 성능은 대체적으로 우수한 것으로 나타났다. 접합부의 강도는 일체식 RC 구조의 비해 1.15배 정도 향상되었다. 층간변위 3.5%때의 강도에서 실험체는 ECC의 인장변형능력과 철골연결재의 항복에 의해 연성거동 하였다.
        4,200원
        196.
        2010.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        RC교량이 내진성능을 확보하기 위해서는 교각의 연성도가 목표연성도에 도달하기 전에 발생하는 전단파괴가 방지되어야 한다. 이를 위해서는 신뢰성 있는 전단강도 평가식이 요구된다. 횡하중을 받는 RC기둥의 전단강도는 변위연성도의 증가에 따라 감소 하는 특성을 나타낸다. 다수의 연구자에 의해 전단강도 식이 제안되어 있으나 변위연성도가 작은 구역에서의 초기전단강도와 연성도 증가에 따른 전단강도의 감소율에서 많은 차이를 보이고 있다. 본 연구에서는 저자들이 제안한 초기전단강도를 기본으로 하여 다른 연구자에 의해서 수행된 많은 기둥실험 결과를 분석하여 변위연성도를 고려한 새로운 전단강도 평가식을 제안하였다, 제안된 평가식은 다른 평가식과의 비교를 통해 정확도가 크게 개선된 것을 확인하였다.
        4,200원
        197.
        2010.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        횡하중을 받는 RC 기둥의 전단강도는 기둥의 변위연성도가 증가함에 따라 감소하는 것으로 알려져 있다. 연성도의 증가에 따른 전단강도의 감소율은 초기전단강도에 따라 크게 좌우되므로 이를 합리적으로 예측하기 위해서는 초기전단강도의 평가가 매우 중요하다. 기둥의 전단거동은 단면모양, 형상비, 축력, 축방향철근비, 연성도 등 다양한 요인에 의하여 영향을 받아 복잡하다. 본 연구에서는 형상비, 단면의 중공비, 축방향철근비, 중공 및 중실단면을 변수로 하는 시험체를 제작하여 실험적 연구를 수행하여 전단거동특성을 살펴보았다. 또한, 축방향철근이 전단강도에 미치는 영향을 분석하여 형상비와 축력을 고려한 기존의 초기전단평가식을 보완하였으며, 그 타당성을 검증하였다.
        4,000원
        198.
        2010.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        공간구조물은 일반 라멘구조와는 다른 동적특성을 가지고 있으며 이런 동적특성에 관해 많은 연구가 수행되고 있다. 그러나 대부분의 연구는 특정 형태의 공간구조물에 대해 수행되었으며 내진설계를 위해 직접적으로 이용 가능한 연구결과는 매우 제한적이다. 본 연구에서는 공간구조물의 기본적인 동적특성을 내재한 트러스-아치구조물을 대상으로 양단의 기둥의 길이가 다른 경우에 트러스 아치구조물의 지진응답변화를 분석하고자 한다. 양단 기둥 길이의 차이에 따라 가속도 응답이 수평방향에 비해 수직방향에서 더 많은 영향을 받는다. 따라서 상부구조물을 지지하는 하부구조물의 강성이 다른 경우에 공간구조물의 내전설계에 있어서 수직방향 응답에 대한 고려가 더욱 많이 요구된다.
        4,000원
        199.
        2010.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        CIT 기둥의 장기거동에 관한 기존의 연구과 실험자료에 의하면 크리프 및 건조수축계수는 외부 강관의 구속효과에 의하여 철근콘크리트 기둥보다 작은 값을 가진다. 본 연구에서는 불확실성이 큰 콘크리트 강도와 특정크리프값과 작용하중을 매개변수로 하여 37층 건물의 CFT 기둥에 대한 확률론적 해석을 수행하였으며 매개변수의 특성을 분석하고 CFT 기둥의 축소량 해석값의 예측범위를 정량화하였다. 본 논문에서는 CFT 기둥축소량의 확률론적 해석을 위한 몬테카를로 (Monte Carlo) 기법을 소개하며 다중매개변수를 동시에 적용하여 매개변수의 변동에 따른 축소량의 영향을 분석하고 신뢰지수별 변동폭을 산정하였다.
        4,000원
        200.
        2009.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 기존 원형 CFT기둥 실험체와 탄소섬유쉬트로 추가구속된 원형 CFT기둥 실험체의 단조압축거동 및 압축내력평가에 관한 실험을 수행하였다. 실험변수는 탄소섬유쉬트 보강겹수와 직경-두께비이며, 실험변수에 따라 총 10개의 실험체를 제작하여 단조압축실험을 수행하였다. 실험을 통하여 기존 CFT 실험체와 탄소섬유쉬트로 구속된 CFT 실험체의 파괴거동, 하중-축변위 곡선, 최대내력, 변형성능을 비교한다. 끝으로 탄소섬유쉬트의 추가구속을 통해 기둥의 국부좌굴을 지연시켰으며 구속효과로 인해 내력은 상승하는 것으로 나타났다.
        4,200원