        In this paper, a numerical study was conducted on the development of HVAC(Heating, Ventilating and Air Conditioning) performance required for a large-scale greenhouse. In order to increase the simulation efficiency, fan model, porous media, and radiator model, etc. provided by Fluent were used based on the part performance analysis such as blowing fans and PTC heaters. Developed simulation method was applied to the decision of fan position to secure the flow uniformity and the determination of the heater specification to maintain the temperature suitable for plant growth. This study is the first step for the development of integrated environmental control system of greenhouse for high-income crop cultivation and the simulation method will be revised after correlation test.
        4,000원
        25.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, durability verification of forged wheels for automobiles were performed using the finite element method for bending fatigue analysis and impact analysis. In addition, the durability analysis environment of forged wheels was implemented. By analyzing the stress distribution on the surface of the forged wheel, the area with a high possibility of breakage was identified and improved. The durability analysis of the initial model forged wheel was performed by bending fatigue analysis and impact analysis, The stress distribution of the forged wheel surface was analyzed through the analysis results of the initial model. and the spokes, flanges, hubs, and rear parts are less likely to be damaged were cut to reduce the weight by about 10%, and the reliability of the improved model was confirmed.
        4,000원
        26.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        배관 시스템은 기체 및 액체 등의 에너지원을 수송하기 위해 사용되며 주로 건물 내부에 설치되거나 지반에 매립되 어 설치된다. 매립된 배관 시스템은 지진이나 지반침하와 같은 큰 상대변위를 받을 수 있으며 이는 배관의 연결부에 손상을 야 기할 수 있다. 벨로우즈는 기하학적 특성으로 축방향 및 회전 변형을 일부 허용한다. 그러므로 벨로우즈 신축관이음을 적용하면 큰 상대변위에 의한 손상을 줄일 수 있는 것으로 예상된다. 하지만 벨로우즈의 성형과정에서 회선의 벽 두께 감소가 발생할 수 있으며 이는 휨 및 인장 성능에 영향을 미칠 수 있다. 본 연구는 단조하중을 받는 벨로우즈 신축관이음의 성능을 분석하기 위 한 실험적 연구를 수행하였다. 또한 단조하중 실험 결과를 바탕으로 벨로우즈 신축관이음의 유한요소모델을 구축하였으며 실험 결과와 비교하여 검증하였다. 검증된 유한요소 모델을 이용하여 회선의 두께 감소에 의한 성능 변화를 분석하였다. 벽 두께 감 소율은 5%, 10%, 15%, 20%, 25%로 가정하였다. 해석 결과 인장 및 휨 하중에 따른 하중-변위 관계의 전체적인 강성과 최대 하 중이 감소하는 것으로 나타났다. 벽 두께 감소율이 25%일 때 인장 및 휨 하중에 따른 최대 하중은 각각 14%, 26% 감소하는 것 으로 나타났다.
        4,000원
        27.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Existing reinforced concrete building structures constructed before 1988 have seismically-deficient reinforcing details, which can lead to the premature failure of the columns and beam-column joints. The premature failure was resulted from the inadequate bonding performance between the reinforcing bars and surrounding concrete on the main structural elements. This paper aims to quantify the bond-slip effect on the dynamic responses of reinforced concrete frame models using finite element analyses. The bond-slip behavior was modeled using an one-dimensional slide line model in LS-DYNA. The bond-slip models were varied with the bonding conditions and failure modes, and implemented to the well-validated finite element models. The dynamic responses of the frame models with the several bonding conditions were compared to the validated models reproducing the actual behavior. It verifies that the bond-slip effects significantly affected the dynamic responses of the reinforced concrete building structures.
        4,000원
        28.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, an incremental loading test of the HRS(Hybrid Rubber Slit) damper was additionally performed to define the physical characteristics according to the incremental test results, and an analytical study was performed according to the damping design procedure by selecting an example structure. As a result of performing seismic performance evaluation before reinforcement by selecting a RC structure similar to an actual school structure as an example structure, the story drift ratio was satisfied, but some column members collapsed due to bending deformation. In order to secure the seismic performance, the damping design procedure of the HRS damper was presented and performed. As a result of calculating the amount of damping device according to the expected damping ratio and applying it to the example structure, the hysteresis behavior was stable without decrease in strength, and the story drift ratio and the shear force were reduced according to the damping effect. Finally the column members that had collapsed before reinforcement satisfied the LS Level.
        4,000원
        29.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Failure to comply with the performance test requirements for the centrifugal pumps at power plants often results in performance dissatisfaction as a result of field tests. This study proposed a method of reducing the uncertainty of the field test results by evaluating the systematic error in the measurement system caused by failure to follow the test requirements using the computational fluid dynamics(CFD) technique. As a result of the evaluation of the systematic error and reflecting it in the performance test data, it was confirmed that the error occurred at a constant rate with respect to the flowrate and that the pump, which showed a difference in performance actually had the same performance.
        4,000원
        30.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the cooling performance change according to the arrangement of the fin-tube heat exchanger using a single tube and the cooling performance change according to the air flow rate were studied. The arrangement of basic heat exchanger was set to 4 columns and 4 rows, and the performance change was studied while changing the columns and rows. In addition, the performance change was investigated by changing the air flow rate of the basic heat exchanger.
        4,500원
        31.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This research was conducted for dewatered sludge cake of industrial wastewater treatment, i.e., as the object of inorganic sludge discharged especially in iron & steel manufacturing shop which used Air drying system to reduce water content. That drying system's single-type cyclone separator was confirmed to have significantly lower separation efficiency on the conditions 20μm and below of particular size through computational fluid dynamics(CFD) analysis. However, we found out the primarily advanced value of separation efficiency on dual-type directly connected. Regarding separation efficiency on size of 10μm, the efficiency of a single-type was presented at 51.91%. On the other side, the efficiency of the dual-type was 97.88%. This advanced effect of the dual cyclone separator was checked at a demo facility of air drying equipment designed by 340m3/min of airflow on site.
        4,000원
        32.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 기존 이력댐퍼와 프리스트레트 철계 형상기억합금(Fe SMA)을 결합한 새로운 하이브리드 댐퍼를 제안하고 이용가능성을 해석적으로 평가한다. 하이브리드 댐퍼는 강진 발생 시 모멘트 프레임의 에너지소산능력을 향상시키고 잔류변형 을 감소시키기 위한 목적으로 제안되었다. 구조해석 프로그램인 OpenSees를 통해 댐퍼의 각 요소에 대한 해석모델을 구축하였 고, 세가지 형식의 강재 가새프레임에 대해 시간이력해석을 수행하였다. 해석결과, 제안된 댐퍼는 모멘트 프레임의 최대 및 잔 류변형을 줄이는데 우수한 것으로 나타났다. 본 연구에 사용된 Fe SMA는 니켈-티타늄(Ni-Ti) 형상기억합금에 비해 5-10%에 해 당하는 낮은 재료 비용을 가지면서도 지진에 취약한 프레임 구조의 내진보강에 효과적인 결과를 보였다.
        4,000원
        33.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As the demand for appropriate heat dissipation measures to improve product stability and performance continues to increase and product design becomes highly integrated, research to improve heat transfer performance while maintaining the same area or size is required. In this study, the sample-shaped aluminum plate was treated as upper-coating, and the thickness of the coating was divided into 1mm, 2mm, and 3mm, respectively, and the coating material was applied with silver, copper, and graphene. The temperature condition of the heat source was set to 473K, and heat dissipation analysis was performed under natural convection. The thermal performance was compared and analyzed through temperature distribution, flow velocity distribution, and heat flux, and it was confirmed that the high thermal conductivity of graphene compared to other materials had a dominant effect on the increase in the conduction heat transfer rate. And it was confirmed that the high surface temperature of the graphene coating also increased the heat transfer rate by convection, thereby enhancing the heat dissipation effect.
        4,000원
        37.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, based on the finite element analysis model verified in previous studies, a new model of a buckling restrained brace reinforced with a steel plate was proposed. A design formula was proposed for the new model to dissipate energy without buckling the steel core under load protocol, and the performance of the model satisfying the design formula was evaluated by comparing it with the previous model through the results of hysteresis loop, bi-linear curve, cumulative energy dissipation capacity, and equivalent viscous damping.
        4,000원
        38.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        교각의 내구성 증진 및 내진 보강을 위하여 원형철근 콘크리트 교각 외부에 강판을 보강한 경우, 교각 외부에서 발 생하는 화재에 대해 보강된 교각의 내화성능을 정량적으로 평가하였다. 범용유한요소해석프로그램 ABAQUS를 이용하였으며 ISO 834-1의 표준화재곡선을 적용하여 교각의 거동을 해석하였다. 해석 변수로는 강판보강두께와 원형교각 지름의 비, 교각에 수직으로 작용하는 축력비를 적용하였다. 교각의 상부와 하부는 힌지-롤러 경계조건을 고려하여 상부는 수직으로 변위가 발생하 도록 하였으며, 교각 외부 전체에 열하중을 가하였고 편심 없는 순수 축하중을 교각 중앙에 가력하였다. 온도에 따른 콘크리트, 철근 및 강재의 비열, 열전도율, 탄성계수 등을 고려하여 보강에 따른 교각의 내화 성능 향상도를 평가하였다. 강판으로 보강한 원형철근 콘크리트 교각은 콘크리트의 중심부일수록 강판 두께의 영향을 받지 않으며 강판 두께별 축력을 주 었을 때 내화시간은 축력비 0.7에서 최대 약 3분 향상되었다. 또한, 보강두께가 두꺼울수록 내하력이 향상하며 60분 이후에 모 두 내하력비가 1.0 이하로 감소하기 시작하는 것을 알 수 있었다. 강판보강공법은 내화성능을 향상시킬 수 있으며 강판 보강 두 께와 보강 지름의 비가 클수록 화재에 대해 축방향에 대한 변위와 내하력이 증가하는 것으로 나타났다. 본 연구결과를 토대로 원형철근 콘크리트 교각의 외부 강판 보강을 통하여 교각의 내화 성능을 향상시킬 수 있음을 정량적으로 판단할 수 있었다.
        4,000원
        39.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 폭발하중을 받는 부재의 저항성능 평가를 위한 모멘트-곡률 관계 기반 수치해석 기법을 소개한다. 직접전단 파괴 모 드를 고려하기 위하여 경험적인 직접전단응력-슬립양 관계를 기반으로 하는 무차원 스프링 요소를 도입하였다. 재료에 대해 정의된 동적증가계수 식을 바탕으로 단면의 모멘트-곡률 관계에 직접적으로 적용가능한 단면의 곡률 변화율에 따른 동적증가계수 식을 제작 하였다. 또한 부착슬립의 영향을 고려하기 위하여 소성힌지영역 내에 등가 휨강성을 도입하였다. 제안된 수치해석 모델의 타당성 검 증을 위하여 실험결과와의 비교연구를 수행하였으며, 단자유도계 모델의 해석결과와의 비교를 통해 본 수치해석 모델의 우수성을 확 인하였다. P-I 선도를 제작하여 부재의 휨 파괴 및 직접전단 파괴에 대한 저항성능을 평가하였으며, 매개변수 연구를 수행하여 P-I 선 도 및 저항성능의 변화를 확인하였다.
        4,000원
        40.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 원예특작시설 내재해형 규격서에 등록되어 있는 폭이 넓은 단동온실(10-단동-5형)을 대상으로 기초의 경계조건과 서까래 강관의 이음 유무에 대해 실물 크기 실험을 실시하고 그 결과를 수치해석 결과와 비교하여 이음부가 있을 때 구조성능 차이에 대해 알아보았다. 각 측정 위치별 변위를 실험에서 측정한 값과 수치해석으로 예측한 값을 비교한 결과에서는 기초의 조건 및 서까래 강관 이음 유무에 상관없이 모두 상당한 차이를 보였고, 힌지 조건 보다 고정 조건이 상대적으로 차이가 컸다. 그리고 모든 절점을 강접합으로 가정하고 구조해석한 결과를 구조실험과 비교한 결과에서는 힌지조건이 고정조건 보다 잘 일치하였지만 해석값이 실험값 보다 크게 나타났다. 수치해석은 모든 절점을 강접합으로 가정했기 때문에 실제 성능과 달랐다. 따라서 현재 모든 절점을 강접합 으로 가정하고 온실을 설계를 하면 과소설계될 우려가 있어 앞으로 신뢰성 높은 온실 설계를 위해서는 서까래와 도리가 교차하는 교차부 성능 특성을 고려한 구조해석 기술 개발이 이루어져야 할 것으로 판단된다.