The purpose in this study is to investigate CT number difference between conventional CT and CT simulator. It shows good correlation in CT number on the muscle, bone, and air. However, in the liver, lungs and water, the low correlation was detected. This result can become the good index for the direction of the distribution of dose difference research between CT equipment for using the computerized radiation therapy planning system.
When scanning PET/CT, dose not unwrinkle gastric folds can be difficult to diagnose gastric cancer. In this study, we use an blowing agent to evaluate the extension the stomach and usefulness of it. The study enrolled 30 patients who patient with uptake in stomach between January and February 2013. Stomach extension was described as the vertical length of the Water drink group was 61.7±9.7 mm, horizontal length was 102.5±17.6 mm and the vertical length of the Blowing agent group was 74.1±10.7 mm, horizontal length was 101.5±14.8 mm in transverse section. Stomach extension was described as the vertical length of the Water drink group was 109.3±18.8 mm, horizontal length was 62.7±18.4 mm and the vertical length of the Blowing agent group was 123.1±23.1 mm, horizontal length was 87.6±14.9 mm in coronal section. Water drink group SUV decreased 35% and Blowing agent group SUV decreased 56%. Blowing agent group extension was similar or superior than water drink group. Therefore, when using a blowing agent will be able to help clinical.
목 적 : 지금까지 생체 부분 간 이식을 위한 공여자의 간 용적 측정에서 방사선을 이용한 CT 3D 용적측정 검사가 매우 우수한 측정방법으로써 시행되고 있으며, 추가적으로 수술 시 공여자의 안정성 판단을 위해 MR 검사가 함께 시행되고 있다. 이에 본 연구에서는 MR 검사와 CT 검사를 함께 시행한 공여자를 대상으로 각각 3D 용적측정 후 그 우수성을 비교 분석해보고자 하였다.
대상 및 방법 : 대상은 간 이식 수술 전 MR 검사와 CT 검사를 함께 시행한 공여자로 남자 23명, 여자 7명이었고, 평균나이 29.1세였다. 검사장비로는 MR Systems Achieva Release 3.2.2.0와 CT Brilliance 64CH를 사용하였으며, 분석장비로는 MR Adw 4.2와 CT Mx View 3.5를 사용하였다. 검사방법은 Primovist 조영제를 사용한 MR 검사 eTHRIVE Portal Phase(Fov 340×340, Thickness 5.0mm) 영상을 MR Adw 4.2 Workstation에서 용적을 측정하였으며, Ultravist 조영제를 사용한 CT 검사는 CT Hepatobiliary Portal Phase(FOV 350×350, Thickness 3.0mm) 영상을 Thickness 5.0mm로 Reconstruction 후 Mx View Workstation에서 용적측정 하였다. 분석방법은 MR 3D 검사와 CT 3D 검사에서 측정된 전체 용적 측정값과 좌엽 용적 측정값이 일치하는지 분석하였다. 공여자의 안정성 판단에서 중요한 사항으로 나타내는 우엽 용적 측정값 비교에서는 실제 수술실에서 적출한 우엽 간 용적값을 MR 3D와 CT 3D의 우엽 용적 측정값과 각 각 비교 분석하였다. 통계방법은 SPSS version 18.0를 사용하여 대응표본 t-test(p < 0.05)와 Pearson 상관계수로 검증하였다(r > 0.001).
결 과 : MR 3D 검사의 전체 용적 측정값은 1238cm³이며, CT 3D 검사는 1402cm³로 전체 평균 용적 측정값이 차이를 보였다(p < 0.05). 좌엽 간의 MR 3D 검사에서 용적 측정값은 450cm³이며, CT 3D 검사에서 용적 측정값은 554cm³으로 좌엽 용적 측정값의 차이를 보였다(p < 0.05). 우엽 간 측정값은 수술 후 적출한 우엽 간 평균 용적 측정값이 678g이었으며, CT 3D 검사의 우엽 용적 측정값은 847cm³(r=0.852)였고, MR 3D 용적 측정값은 787cm³ (r=0.871)로 측정되었다.
결 론 : 지금까지 간 이식 공여자는 이식 될 우엽 간을 미리 예측하기 위하여 주로 CT 3D 용적 측정검사를 하였다. 그러나 MR 3D 용적 측정검사 역시 CT 3D 용적 측정검사와 함께 매우 정확하고 우수한 측정방법으로써 증명되었으며, MR 3D 용적 측정검사가 간 이식 전 공여자의 안정성 판단에 중요한 검사가 될 것으로 사료된다.
본 연구는 조영제를 사용하는 CT검사에서 조영제 부작용이 발생한 환자에 대한 정보를 수집하고 분석하여 조영제 부작용 발생인자들을 분석하여 조영제 부작용을 미리 예측하고 예방하여 조영제 부작용 발생빈도를 최소한으로 줄이고자 하며, 병원 내 약물부작용 관리 업무에 기초자료로 활용하여 병원의 진료 서비스의 향상과 영상의학과 종사자들의 업무 효율성을 증대시키고자 한다. 연구 대상은 대전광역시에 소재하는 4개의 종합병원에서 조 영제를 사용하는 CT 검사 중 만 18세 이상 남녀를 대상으로 2010년 1월부터 2014년 7월 까지 전산으로 기록되어진 4,932명 중 변수가 부족한 데이터를 제외하고 조영제 부작용이 발생한 환자 404명(이하 환자군)과 같은 기간 조영제 부작용이 발생되지 않은 환자에서 조영제 부작용이 발생한 환자의 성별, 조영제 종류를 교차하여 무작위 추출을 한 404명 (이하 대조군)을 대상으로 분석하였다. 기존에 알려진 위험 인자에 대해서 본 연구에서는 일반적 특성에 따른 조영제 부작용은 계절에 따른 특성에서 봄에 검사한 환자보다 겨울에 검사한 환자가 조영제 부작용 발생확률이 높게 나타나는 것으로 유의한 차이가 있었고, 다른 특성에서는 유의한 차이가 없었다. 조영제 부작용검사 관련 특성에서는 일반적인 검 사보다는 Dynamic 검사 시 조영제 부작용 발생확률이 높게 나타났고, 조영제 사용량이 130ml 이상 시, 주입속도가 4F/R 이상 시 조영제 부작용 발생확률이 높게 나타나는 것으 로 모든 특성들이 유의하게 차이가 나타남을 알 수 있었다. 계절적 변화에 따라 환자의 조영제 투입 시 세심한 주의가 필요하리라 생각되며, 매년 CT검사가 증가하고 있는 만큼 조영제 사용이 증가 할 것으로 예상되기 때문에 조영제 부작용의 일반적 특성뿐만 아니라 질병, 전처치, 심리적 요인, 기타 약물 복용, 등의 다양한 원인을 근거로 한 연구가 지속적 으로 진행되어야 하며 이러한 연구들을 통해 조영제 부작용의 발생 위험을 사전에 예방할 수 있는 체계적이고 효율적인 프로그램의 개발이 필요하리라 생각된다.
The number of CT gradually tends to increase, but radiation exposure includes higher exposure dose of patients than other test methods as the rate of 67% in the whole radiology tests. Exposure dose of patients has increased due to it and the second exposure has been done by scattered rays of other organs except for test sites. Especially, special shielding has not been done in gonad which is very sensitive to radiation in brain and chest CT. So this study tries to research the second exposure dose of the gonad and how to shield it in Chest CT which does not include it. It was intended for 20 male adults who are 30 years old and conduct chest CT. SIEMENS’s SOMATOM DEFINITION AS* was used as CT equipment. For the scanning conditions, The tube voltage is 120kv, the tube current is 90mAs, and the slice thickness is 3mm as the general chest CT conditions. CHIYODA TECHNOL CORPORATION’s FGD1000 was used as Glass dosimeter (PLD). A lead pad of 0.25mmPb was produced as the shielding board. For the research method, the shielding rate was compared by measuring exposure dose of the gonad before and after shielding and the usefulness of the shielding board was evaluated. The average exposure dose of symphysis pubica before shielding was 280.5μGy and the average exposure dose of coccyx was measured as 151.5μGy. The average exposure dose of symphysis pubica after shielding the gonad with a lead pad of 0.25mmPb was 42μGy and the average exposure dose of coccyx was measured as 41μGy.
We performed the quantitative analysis using MATLAB for slice thickness, spatial resolution, and low contrast resolution with the 50 received images which have suitable judgement by scanning AAPM phantom using GE, PHILIPS, SIEMENS, and TOSHIBA. Slice thickness and spatial resolution were measured by using full width at half maximum(below FWHM). Spatial resolution was confirmed that FWHM interval more than 1.0 mm size. Low contrast resolution was measured that how close by using Roundness Index(below RI) until 6.4 mm size. The spatial resolution 9 images and low contrast resolution 10 images which have disapproved judgement were also had the quantitative analysis. The statistic analysis was judged to have statistically significant differences when p-value is less than 0.05 through SPSS statistics 19.0 and T-test (paired t-test). For slice thickness 5 mm, the average qualitative evaluation group shows 4.98 mm and quantitative evaluation group shows 5.02. For slice thickness 10 mm, the average qualitative evaluation group shows 9.98 mm and quantitative evaluation group shows 9.86. No significant differences (p=0.07, p=0.06) with 5 mm and 10 mm. It confirmed the interval for all FWHM until 1.75, 1.50, 1.25, 1.00 mm as approved images on spatial resolution ,and the average distance was 0.102 mm and the minimum distance 0.054 mm. For disapproved images, all interval was not showed under 1.00 mm. For low contrast resolution, spproved image’s RI value shows average 0.81 and minimum 0.77. The disapproved image’s RI average shows 0.70. Statiscally significant differences were presented (all p<0.05) following hole size.
When scanning PET/CT, dose not unwrinkle gastric folds can be difficult to diagnose gastric cancer. In this study, we use an blowing agent to evaluate the extension the stomach and usefulness of it. The record of 30 patients with local or total uptake of stomach between January and February 2013. Stomach extension was described as the vertical length of the Water drink group was 61.7±9.7 mm, horizontal length was 102.5±17.6 mm, the vertical length of the Blowing agent group was 74.1±10.7 mm, horizontal length was 101.5±14.8 mm in transverse section. Stomach extension was described as the vertical length of the Water drink group was 109.3±18.8 mm, horizontal length was 62.7±18.4 mm, the vertical length of the Blowing agent group was 123.1±23.1 mm, horizontal length was 87.6±14.9 mm in coronal section. SUV results in decrease 35% for water drink group, decrease 56% for blowing agent. When the use blowing agent group extension of stomach was similar or superior than water drink group. Therefore, when using a blowing agent will be able to help clinical.
막대한 예산이 투입된 정부연구개발사업에 대한 성과창출과 관리 등에 대해서 근래에 관심이 집중되고 있다. 이 연구에서는 정부연구개발사업의 혁신 및 사업화 성과 창출 경로를 추정할 수 있는 연립방정식 모형을 설계하여 산업에 따른 성과창출의 특성을 분석하였다. 이를 위해서 KEIT 산업기술혁신사업의 성과활용현황조사 데이터를 활용하였으며, 정보통신(IT) 산업과 화학(CT) 산업을 대상으로 하였다.이 연구의 결과는 다음과 같다. 모든 기업들은 정부지원금을 통해 개발된 기술을 특허를 통해 보호하고 혁신을 파급시키는 역할을 하고 있었으나, 특허를 사업화하는 것은 IT 산업에서는 중소기업, CT 산업에서는 대기업으로 나타났다. 복합산업 성격인 IT 산업의 중소기업은 기업의 자체적인 혁신노력이 추가적으로 필요한 반면에 CT 산업의 중소기업은 기술개발과 사업화 성과 향상에 있어서 협력연구 등의 지원이 효과적이었다. 이러한 결과는 정부연구개발사업으로 창출된 성과를 향상시키기 위해서 정부 정책 및 과제 기획 시 산업별ㆍ기업별 특성에 따라 주안점을 달리 해야 한다는 것을 시사한다.
Recently, 18F-FDG PET based CT scan was a critical examination that the after, before plan diagnosis and treatment of tumors. But, due to the distortion of SUV that should be proportional to the metabolic rate of glucose in the tumor, the other measurement methods are being on study. In this study, compared the degree of distortion of SUV that according to the volume of the tumor analysis ROI and VOI using the NEMA IEC Phantom. The results, the SUVmax, mean value are rapidly decreased with threshold value 500 mm2 interval of the ROI analysis, 1500 mm3 interval of the VOI analysis. When compared SUVmax value SUVmean, ROI and VOI analysis VOI measurements was 1.077 times higher SUVmax was 0.981 times highe compared to the value of the ROI measurement. Compare MTV, SUV 2.0 as measured by the volume of the VOI to Volume showed a slightly higher results(Volume / MTV = 93.4 % ±14.8 %). Considering the above results, Tumor evaluation by 18F-FDG PET / CT scan Consider each threshold value should be analyzed due to larger SUV's Distortion depending on the size of the tumor. VOI analysis is recommended. because it showed the VOI analysis is higher than the ROI analysis SUVmax and lower SUVmean due to VOI analysis than once as a measure of the wider area as measured ROI analysis. MTV (R2 = 0.999), a result close to the actual size of the tumor. but, more research is needed in this regard, because SUV according to the standards of value are affected.
의료영상에서 잡음제거는 의료영상 분야에서의 중요한 도전 과제들 중의 하나이다. 최상의 진단 결과를 얻기 위해서는 잡음과 아티펙트가 제거되고, 선명하며 깨끗한 화질의 의료영상이 필요하다. CT는 의료영상에서 중요하고 가장 보편적인 모달리티이다. CT 영상에서 주요 잡음은 양자화 잡음이다. 본 논문에서는 CT 영상에서 잡음 제거를 위한 하이브리드 필터를 제안하였다. 제안된 하이브리드 필터는 바이래터럴 필터, 신경망 윤곽선 검출기, 다층 신경망 등으로 구성되어 있다. 다층 신경망은 여러 정보들을 결합하여 개선된 출력 영상을 만들기 위한 융합 연산자로서 이용되었다. RMSE, ISNR, MSR과 CNR과 같은 화질 평가 척도가 잡음 개선의 성능 평가를 위해 사용되었다. 또한, 시각적으로도 제안된 필터가 다른 필터들에 비해 우수한 결과를 보였다. 이와같은 화질 평가 척도에 의해 본 논문에서 제안된 필터는 바이래터럴 필터나 가이드 필터보다 우수하였다. 특히, 심한 잡음이 있는 상황에서 제안된 필터는 우수한 결과를 보였다.
Periodontal inflammation increases the risk of tooth loss, particularly in cases where there is an associated loss of alveolar bone and periodontal ligament (PDL). Histological and morphometric evaluation of periodontal inflammation is difficult. Especially, the lengths of the periodontal ligament and interdental alveolar bone space have not been quan-tified. A quantitative imaging procedure applicable to an animal model would be an important clinical study. The purpose of this study was to quantify the loss of alveolar bone and perio-dontal ligament by evaluation with micro-computed tomo-graphy (micro-CT). Another purpose was to investigate diffe-rences in infections with systemic E. coli LPS and TNF-α on E. coli lipopolysaccharide (LPS) in loss of alveolar bone and periodontal ligament model on mice. This study showed that linear measurements of alveolar bone loss were repre-sented with an increasing trend of the periodontal ligament length and interdental alveolar process space. The effects of systemic E. coli LPS and TNF-α on an E. coli LPS-induced periodontitis mice model were investigated in this research. Loss of periodontal ligament and alveolar bone were eval-uated by micro-computed tomography (micro-CT) and cal-culated by the two- and three dimensional microstructure morphometric parameters. Also, there was a significantly increasing trend of the interdental alveolar process space in E. coli LPS and TNF-α on E. coli LPS compared to PBS. And E. coli LPS and TNF-α on E. coli LPS had a slightly increa-sing trend of the periodontal ligament length. The increa-sing trend of TNF-α on the LPS-induced mice model in this experiment supports the previous studies on the contribu-tion of periodontal diseases in the pathogenesis of systemic diseases. Also, our findings offer a unique model for the study of the role of LPS-induced TNF-α in systemic and chronic local inflammatory processes and inflammatory diseases. In this study, we performed rapidly quantification of the perio-dontal inflammatory processes and periodontal bone loss using micro-computed tomography (micro-CT) in mice.
본 논문에서는 최근 미국 연방대법원이 Kirtsaeng v. John Wiley & Sons, Inc. 133 S.Ct. 1351 판결을 통해 긍정하는 취지의 결론을 내리면서 논쟁이 재점화 되고 있는 저작권의 국제적 소진 이론(Doctrine of international copyright exhaustion)에 대한 종합적 검토를 위하여 첫째로, (i) 저작권의 국제적 소진 쟁점에 대해 가장 풍부한 논쟁을 펼쳐왔던 미국에서의 논의 상황을 최근 2013. 3. 19. 선고된 미국 연방대법원의 Kirtsaeng v. John Wiley & Sons, Inc. 133 S.Ct. 1351 판결(이하“Wiley 연방대법원 판결”) 내용을 중심으로 검토해 보고 (ii) 나아가 일본에서의 논의 상황과 (iii) 우리나라에서의 종래 논의 상황까지 망라적으로 점검해 보았다. 나아가 둘째로, 그 검토 내용을 기초로 (i) 미국에서의 논의, 특히 Wiley 연방대법원 판결의 입장에 대해 비판적으로 평가하면서, 해당 판결 중 한국에서의 논의에 참작할만한 시사점에 관해 제시해 보고, (ii) 일본에서 저작권의 국제적 소진 처리 방향을 평가하고 역시 우리나라에서의 논의에 참고할만한 시사점을 제안해보면서, (iii) 더불어 우리나라 종래 논의의 문제점에 대해 비판적으로 검토해 보았다. 그리고 마지막 셋째로, 이상의 검토 결과들을 바탕으로 (i) 한국에서 현행 저작권법상 국제적 소진 쟁점에 대한 타당한 처리 기준을 제시하면서, 나아가 (ii) 추후 우리나라 저작권법에 대한 입법론까지 제안해 보았다. 최근 영화∙음반∙컴퓨터 프로그램 등 창작 과정에 막대한 자본이 투입되면서 산업적∙객관적 효용성이 주된 성격을 차지하는 저작물들이 증가하게 됨에 따라 저작권의 국제적 소진 이론이 논의되는 영역은 급격히 확대되고 있는데 반하여, 저작권의 국제적 소진과 관련해서 저작권법에 명확한 규정을 두고 있는 일본과 달리 우리나라의 경우에는 그와 같은 규정을 두고 있지 않아 그 인부나 기준 등에 대하여 최근까지도 통일적인 해석에 이르지 못하고 논란이 계속되어 저작권법 체계의 법적 안정성에 심각한 위협이 되어 왔다. 이에 따라 최근 미국 연방대법원 판결 선고를 계기로 미국, 일본 및 한국에서의 현재까지의 저작권의 국제적 소진 이론 논의 전반에 대해 종합적으로 검토하고, 우리나라에서 추후 문제될 수 있는 저작권 국제적 소진 관련 쟁점들에 대한 타당한 처리 기준을 제시해보고자 한 본 논문의 연구결과가 향후 저작권 법체계의 안정과 인류의 문화 및 관련 산업 발전에 미력하나마 기여할 수 있기를 희망한다.
Periodontal disease induces an increased incidence of tooth loss, particularly in cases with an associated loss of alveolar bone and periodontal ligaments. In this study, alveolar bone loss was detected by micro-computed tomography (CT) following exposure to E. coli lipopolysaccharide (LPS) in a streptozotocin (STZ)-induced diabetic mouse model. A 10 mg/ml dosage of E. coli LPS was applied between the first, second and third molars of the mice three times a week for 10 weeks. The loss of periodontal ligaments and alveolar processes was then evaluated by micro-CT using two and three dimensional microstructure morphometric parameters. In the diabetic mice, E. coli LPS induced the destruction of periodontal ligaments and loss of alveolar process spaces. The distances between periodontal ligaments were significantly widened in the STZ-LPS group compared with the untreated STZ group. The 10 mg/ml exposure to E. coli LPS in the STZ mice also resulted in a significant decrease in the alveolar bone volume fraction. The results of our study suggest that alveolar bone loss can be readily detected by volumetric micro-CT analysis as an increase in the distance between periodontal ligaments and in the alveolar process length.
대표적인 다상 재료인 콘크리트는 구성 성분의 공간적 분포에 의해 재료 특성이 큰 영향을 받는다. 특히 공극(void)은 콘크리트의 특성에 큰 영향을 주는 요인으로서, 콘크리트 내부에 분포하는 공극의 공간적 분포를 파악하는 것은 재료의 특 성을 이해하는데 매우 중요하다. 본 연구에서는 콘크리트 내부에 존재하는 경량 골재의 공극 분포 분석을 위해서, CT(computed tomography)로부터 얻은 단면 이미지를 활용하여 생성된 3차원 경량 골재 이미지를 활용하여 공극 분포를 시각화(visualization)하였다. 방향에 따른 3차원 경량 골재 내부의 공극 분포 상태를 정성적으로 묘사하기 위해서 확률 분 포 함수인 두점 상관함수(two-point correlation function)를 사용하여 공극의 공간적 분포 경향을 구(sphere)에 표현하였다. 또한 방향에 대한 골재의 강성도(stiffness)를 계산하여 각 방향에 따른 골재의 역학적 물성치 분포 변화를 확인하였다. 각 방향으로의 확률 분포 함수로 표현된 공극 분포와 강성도 분석함으로서 CT 이미지를 통한 공극 분포 특성 분석 및 경량 골재의 역학적 특성을 효과적으로 예측할 수 있음을 확인하였다.
본 연구는 117개의 문화기술개발 수혜기업을 표본으로 문화기술(CT)개발지원 정책과 기업 R&D성과와의 관계를 실증분석하였다. 연구결과, 문화기술개발정책은 기업 R&D성과제고에 매우 중요한 역할을 하는 것으로 분석되었다. 특히 문화기술개발정책이 사업타당성 및 적절한 사업운영체계를 갖는 것은 전 주기적인 기업R&D성과향상에 유의적인양의 영향을 미쳤다. 곧, 타당한 문화기술개발정책은 기업이 단순히 R&D단계에 머물지 않고 기술적 성과를 발생시키며 나아가 경제적성과(사업화 성과)를 향상시킬 수 있도록 돕는 촉매역할을 하는 것으로 나타났다. 따라서, 문화기술개발정책이 시행되기 앞서 시장수요에 기반한 사업타당성확보가 선행되어야 하고 R&D지원후에도 기업과 지속적인 커뮤니케이션을 통해 정책 개선노력을 기울여야 할 것으로 보인다.
OP-FTIR(Open-path Fourier Transform Infrared)을 광학적 센서로 활용하여 혹은 유독가스의 옥외 누출 및 농도분포를 신속하게 파악할 수 있는 유해가스 검색시스템을 가상환경 상에 구성하였다. 유해가스의 확산환경은 풍동실험과 유사하도록 CFD 모델을 사용하여 구성하였다. 신속한 연산이 가능하도 록, 1개의 가우스 함수를 사용한 SBFM 기법을 토대로 CT 프로그램을 만들었다. 캐노피 층보다 높은 고도 면에서 CFD 농도장 시뮬레이션으로부터 OP-FTIR 광로 통합농도 신호를 구성하였다. 이 신호를 CT 프로그램에 적용하여 CFD 농도장을 역추정한 후 CFD 결과와 비교해 봄으로써, OP-FTIR을 이용한 관 측시스템의 성능을 평가하였다. 단순한 시스템임에도 불구하고, 비교적 만족스러운 성능을 보였다.
추적자 SF6 가스농도의 공간분포를 예측하기 위하여 수동형 리모트 센싱 기술과 컴퓨터 단층 측정 기술을 접목시켜 도시모델을 모사한 풍동에서 시나리오에 따라 실험을 수행하였다. 풍동실험의 시나리오는 거리에 따른 스캐닝 방식과 각도에 따른 스캐닝 방식으로 실험을 수행하였고, OP-FTIR 원격 감시장비는 SF6 가스의 광로통합농도를 구하기 위하여 사용되었다. 또한 제안한 SBFM(Smooth Basis Function Minimization) 알고리즘은 SF6 가스농도를 공간정보를 예측하기 위하여 사용되었으며 최적의 Gaussian 함수 개수를 구하기 위하여 1개, 2개 및 3개의 Gaussian 함수를 적용하여 실험하였다. 실험 결과 SBFM 알고리즘에 의한 SF6 농도분포의 예측 결과는 실제 측정 결과와 비교할 때 1개의 Gaussian 함수를 적용한 결과의 상관계수가 0.755로 가장 잘 일치하였다. 아직 컴퓨터 단층 기술과 수동형 리모트 센싱 기술의 결합된 기술이 실험실적 연구단계이지만 SBFM 알고리즘과 기하학적 빔 스캐닝 기술이 보다 향상된다면 대기오염 감시 및 국방 분야에 폭 넓게 응용될 것으로 기대된다.
The decrease of the distance between particle centers due to the growth of the sinter necks can be explained by the well known two-particle model. Unfortunately this model fails to provide a comprehensive description of the processes for 3D specimens. Furthermore, there is a significant discrepancy between the calculated and the measured shrinkage because particle rearrangements are not considered. Only the recently developed analysis of the particle movements inside of 3D specimens using micro focus computed tomography (μCT), combined with photogrammetric image analysis, can deliver the necessary experimental data to improve existing sintering theories. In this work, μCT analysis was applied to spherical copper powders. Based on photogrammetric image analysis, it is possible to determine the positions of all particle centers for tracking the particles over the entire sintering process and to follow the formation and breaking of the particle bonds. In this paper, we present an in-depth analysis of the obtaine data. In the future, high resolution synchrotron radiation tomography will be utilized to obtain in-situ data and images of higher resolution.