검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 411

        28.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We investigated the spatial distribution of heterotrophic bacteria associated with different water masses in the northern East China Sea (ECS) in summer. The surface water masses were divided into the Changjiang Diluted Water (CDW) and high salinity water (HSW). In the CDW region, the concentrations of dissolved inorganic nitrogen (DIN) and chlorophyll-a (Chl-a), and micro Chl-a contribution were high; and bacterial abundance (BA) and ciliate abundance (CA) were also high. In the HSW region with relatively low DIN concentrations, Chl-a concentration and micro Chl-a contribution were low, but pico Chl-a contribution was increased compared to those in the CDW region. BA did not show any significant difference from the CDW region, but CA was decreased. BA showed a positive correlation with Chl-a concentration in the CDW region; however, it did not show a significant correlation with Chl-a concentration in the HSW region. The ratio of bacterial carbon biomass/phytoplankton carbon biomass was exponentially increased with a decrease in the Chl-a concentration. Compared to the past (1990-2000s), the surface phosphate concentrations and the size of dominant phytoplankton have recently decreased in the ECS. Considering this trend of nutrient decrease and miniaturization of the phytoplankton, our results indicate that changes in the strength of the oligotrophic water mass could alter the function of the microbial food web.
        4,300원
        29.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 미생물 첨가에 따라 거세한우 비육우 분의 이화 학적 특성, 미생물 성상, 가스발생량 및 퇴비 부숙도에 미치는 영 향을 규명하고자 수행하였다. 이상의 결과를 종합하면, 4주 후,미생물 첨가구에서 수분, 유기물, 총질소 함량 및 pH가 낮았으며, 나머지 이화학적 특성에서는 차이가 나타나지 않았다. 유산균과 효모균 수는 증가하였으며, 대장균 수는 감소하였다. 12주 후, 미 생물 첨가구에서 유산균과 고초균 수는 높았으나, 수분, 효모 및 대장균 수는 낮게 낮았다. 하지만 암모니아, 황화수소 발생량과 퇴비 부숙도는 미생물 첨가에 의한 효과가 나타나지 않았다. 따라 서, 거세한우 분에 미생물을 첨가하면 유익균은 증가하고, 병원성 미생물은 감소하여, 비육우의 생산성은 증진될 것으로 사료되지 만, 가스 발생량 및 퇴비 부숙도에 대한 추가적인 연구는 지속적 으로 수행되어야 할 것으로 사료된다.
        4,000원
        30.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 사일리지 발효제 첨가가 볏짚 사일리지에서 곰팡이 독소 및 in situ 섬유소 소화율에 미치는 영향을 평가하고자 실시 하였다. 사일리지 발효제로 L. plantarum 단일제 및 L. plantarum 과 S. cerevisiae의 혼합제를 첨가하였을 때 사일리지의 발효 및 섬유소 분해에 영향을 주었을 뿐만 아니라 곰팡이독소 감소에도 영향을 주었다. 시험 시료에서 곰팡이독소 중 ochratoxin A 및 zearalenone만 발견되었다. Ochratoxin A 및 zearalenone는 대조구에서 각각 38.11±2.22 및 633.67±50.30 ug/kg 수준으로 발효제 첨가로 감소 경향이 나타났고, 혼합제에서만 각각 27.78±2.28 및 392.72± 25.04 ug/kg 수준으로 유의적 차이를 보였다(p<0.05). pH는 대조 구에 비하여 단일제 및 혼합제에서 낮았고(p<0.05), lactic acid는 대조구(8.18±0.93 mM)에 비하여 단일제(11.73±0.31 mM)가 높았고, 혼합제(16.01±0.88 mM)에서 가장 높은 수준을 나타내었다 (p<0.05). Acetic acid와 propionic acid는 발효제 첨가에 따라 유 의적으로 낮아짐을 발견하였다(p<0.05). 그리고 total VFA도 발 효제 첨가가 대조구에 비하여 낮았다(p<0.05). NDF 및 ADF의 반추위 in situ 분해율은 배양기간 동안 혼합제가 가장 높은 수준 의 분해율을 유지하였고, 다음으로 단일제가 높았으며, 대조구가 가장 낮은 수준을 유지하였다. 그리고 이들 NDF 및 ADF 분해율 은 각각 배양 12 및 24시간 이후 모든 시간대에서 실험구간 유의 차를 나타내었다(p<0.05). 이상의 연구 결과는 볏짚 사일리지 제조에서 사일리지 발효제 사용은 발효 및 섬유소 분해에 영향을 주었을 뿐만 아니라 곰팡 이독소 감소에도 영향을 주었다. 그리고 곰팡이독소 감소는 L. plantarum 단일제보다 L. plantarum과 S. cerevisiae 혼합제의 효능이 더 크게 나타났다. 따라서 사일리지 조제를 위한 발효제로 L. plantarum과 L. plantarum 첨가제의 사용은 사일리지의 품질 과 안정성을 더 증진할 것으로 사료 된다.
        4,000원
        31.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 비가열 떡 제조업체 3곳을 대상으로 원 재료, 제조설비 및 계절별 제조공정에 대한 미생물 오염 도를 분석하였고, 여름철 불림 시간에 따른 미생물 오염 도 및 불림 수 온도 조절을 통한 미생물 저감 효과를 확 인하고자 하였다. 3업체의 원재료 일반세균수는 2.69-5.08 log CFU/g 범위로 검출되었으나 제조공정 중 불림공정에 서 미생물 오염도가 급격히 증가함을 확인하였다. 계절에 따른 제조공정별 미생물 오염도 분석결과, 여름철 불림공 정에서 일반세균 및 대장균군이 7.01 및 3.96 log CFU/g 로 다른 계절에 비해 유의적으로 높게 나타났고, 이후 공 정에서도 높은 오염도를 유지하여 냉동공정에서 일반세균 이 6.24 log CFU/g로 법적인 기준을 초과하여 검출되었다. 여름철 불림 초기 수온은 19.1oC에서 불림 12시간 후 26.8oC까지 상승하였고, 불림시간에(3, 6, 9, 12 h) 따른 제조공정별 미생물 오염도 분석결과, 불림시간이 길어질수 록 미생물 오염도가 유의적으로 높게 나타났고, 불림 9시 간 이후부터 냉동공정의 일반세균 수치가 냉동식품의 법 적인 기준을 초과하여 검출되었다. 여름철 불림 수의 온 도 상승을 억제하기 위하여 얼음팩을 이용하여 불림 수온 을 조절한 결과, 불림 12시간까지 20.1oC로 유지되어 조 절 전보다 약 7oC가량 낮게 나타났다. 이에 따른 제조공 정별 미생물 오염도 분석결과, 3업체의 불림 12시간 이후 냉동공정 일반세균 평균값이 4.42 log CFU/g로 조절 전보 다 1.77 log CFU/g 감소한 것으로 확인되었다. 이상의 결 과로 볼 때, 안전한 비가열 냉동떡 생산을 위해서는 업체 에 맞는 불림시간 및 불림 수 온도조절 등의 선행요건 관 리기준 설정이 필요하며, 이러한 선행요건 관리기준의 적 용으로 비가열 냉동떡 제조 HACCP system의 안전성이 확립될 수 있을 것으로 판단되었다.
        4,200원
        32.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The present trial verified the effects of spraying microbial agents on odor reduction in commercial pig farms of different operating sizes and barn types. Farms without microbial agent spraying and those sprayed with microbial agents at two different intervals were compared. The treatments included spraying of water alone every day or a mixture of water plus microbial agent at 24 and 72 h intervals. The experimental farms were divided according to size into 1,000-, 3,000-, and 5,000-head farms and according to barn type into gestation, farrowing, nursery, and grower-finisher farms. To compare odor concentration within each housing barn, ammonia and hydrogen sulfide gas levels were measured. The average concentrations of ammonia (p<0.01) and hydrogen sulfide (p<0.05) gas were the lowest in all types of farms sprayed with the microbial agent at a 24 h interval. In farms sprayed with the microbial agent at a 24 h interval, the decrease in ammonia concentration according to barn type was in the following order: farrowing (p<0.01) (11.0 to 1.8 ppm), nursery (p<0.05) (17.0 to 9.2 ppm), grower-finisher (15.3 to 8.8 ppm), and gestation (9.7 to 6.4 ppm) farms. Moreover, spraying the microbial agent at a 24 h interval significantly (p<0.01) decreased ammonia concentration from 19.9 to 10.4 ppm, from 11.1 to 4.1 ppm, and from 8.8 to 5.1 ppm in 5,000-, 3,000-, and 1,000-head farms, respectively. Overall, spraying microbial agents every day may be the most effective method to reduce odor in commercial pig farms.
        4,000원
        36.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we compared the microbial reduction effects of drying, hot water, and microwave sterilization in scourers and dishcloths to suggest a most suitable sterilization method. Three scourer types (silver, copper, and mesh) were used, and three dishcloth types (silver, bamboo, and cotton) were used. Drying time dependent reduction in Escherichia coli was high in silver and copper scourers, but minimal bacterial reduction was obtained against Bacillus cereus in all scourers and dishcloths. In scourers, E. coli was not detected after ≥30 s of hot water sterilization at 77oC, and B. cereus was not detected after ≥60 s of hot water sterilization at 100oC. In dishcloths, E. coli was not detected after hot water sterilization at 77oC for ≥30 s, but B. cereus was detected after hot water sterilization at 100oC for ≥60 s. In scourers, E. coli was not detected after microwave sterilization at 700 W for 3 min, but B. cereus was detected. In dishcloths, E. coli was not detected after microwave sterilization with 700 W for ≥1 min, but B. cereus was detected in the cotton dishcloth even after sterilization for 3 min. In conclusion, the use of antimicrobial scourers (silver and copper) and dishcloths (silver and bamboo) are not sufficient to reduce the microbial contamination. The guideline provided by the Ministry of Food and Drug Safety suggesting dishcloth sterilization via hot water at 100oC for 30 s was also found to be insufficient. Based on our research, we suggest that the most effective methods of microbial management are submerging scourers in hot water at 100oC for ≥1 min, and sterilizing dishcloths for ≥3 min using a 700 W microwave.
        4,000원
        39.
        2022.10 구독 인증기관·개인회원 무료
        Safe storage of spent nuclear fuel in deep underground repositories needs an understanding of the long-term alteration (corrosion) of metal canisters and buffer materials. We conducted a small-scale laboratory alteration tests on some metal (Cu and Fe) chips by embedding them into the compacted bentonite blocks, which were placed in anaerobic water for 1 year. Some additives like lactate, sulfate, and bacteria were separately loaded into the water to promote biochemical reactions. The bentonite blocks immersed in the water were finally dismantled after 1 year, and they showed that their alteration was insignificant. However, the Cu chip exhibited some microscopic etch pits on its surface, wherein sulfur component was slightly detected. Overall, the Fe chip was more corroded than the Cu chip under the same condition. The secondary phase of the Fe chip was locally found as carbonate materials, such as siderite (FeCO3) and calcite ((Ca, Fe)CO3). These secondary products could imply that the local carbonate production around the Fe chip may be initiated by an evolution (alteration) of bentonite and a diffusive provision of biogenic CO2 gas. These laboratory scale test results suggest that the long-term alteration (corrosion) of metal canister/bentonite blocks in the engineered barrier could be possible and may be promoted by microbial activities.
        1 2 3 4 5