We calculate the energy spectra of cosmic ray (CR) protons and electrons at a plane shock with quasi-parallel magnetic fields, using time-dependent, diffusive shock acceleration (DSA) simulations, including energy losses via synchrotron emission and Inverse Compton (IC) scattering. A thermal leakage injection model and a Bohm type diffusion coefficient are adopted. The electron spectrum at the shock becomes steady after the DSA energy gains balance the synchrotron/IC losses, and it cuts off at the equilibrium momentum peq. In the postshock region the cutoff momentum of the electron spectrum decreases with the distance from the shock due to the energy losses and the thickness of the spatial distribution of electrons scales as p-1. Thus the slope of the downstream integrated spectrum steepens by one power of p for pb < p < peq, where the break momentum decreases with the shock age as pbr ∝ t-1. In a CR modified shock, both the proton and electron spectrum exhibit a concave curvature and deviate from the canonical test-particle power-law, and the upstream integrated electron spectrum could dominate over the downstream integrated spectrum near the cutoff momentum. Thus the spectral shape near the cutoff of X-ray synchrotron emission could reveal a signature of nonlinear DSA.
A plane-parallel model of the diffuse Galactic light (DGL) is calculated assuming exponential disks of interstellar dust and OB stars, by solving exactly the radiative transfer equation using an iterative method. We perform a radiative transfer calculation for a model with generally accepted scale heights of stellar and dust distribution and compare the results with those of van de Hulst & de Jong for a constant slab model. We also find that the intensity extrapolated to zero dust optical depth has a negative value, against to the usual expectation.
The "Jeongjagak(丁字閣, T shaped building)" was important building from Goryeo Dynasty to Joseon Dynasty. For long period, the scale and form of the building had been changing bit by bit. The change of building results from the function. As the Jeongjagak accepted the functions of the Yeongakjeon(靈幄殿), there appeared changes of plane. The main function of Yeongakjeon was suppling space for the dead king's coffin. The Yeongakjeon was not built in the first year of King Sukjong(1674). At that time, the Jeongjagak was responsible for the function of the Yeongakjeon as an alternative. Starting from this, the Jeongjagak was used as space for the dead king's coffin. Because the coffin should place on from south to north, it demanded long inner space in south-north direction. Therefore the effort to make enough length in south-north direction was begun from the first year of King Sukjong(1674). In order to solve the problem, the Toigu(退構) was made from the reign of King Sukjong to the 28th year King Youngjo(1852). The Toigu was temporary inner space which was made in one compartment at the Baewichung(拜位廳, the part of the Jeongjagak). But the length of the Jeongjagak's south-north direction was reduced to 61.8m(20尺6寸) at the 33th year of King Youngjo(1857) when the 『Gukjosangryebopyon(國朝喪禮補編)』 was completed. Also it extended to 84m(28尺) during the reign of King Jeongjo(1774~1800). Following these process of extension and reduction, the length was standardized as 72m(24尺) at the reign of King Sunjo(1800~1834). These facts explains that the main cause of plane change at the Jeongjagak was acceptance of functions that was used as space for the dead king's coffin. Also, the important points of change at the Jeongjagak were the first year of King Sukjong, the 33th year of King Youngjo and the first year of King Sunjo. When it was the first year of King Sukjong and the 33th year of King Youngjo, there were two national funerals. Because of concern about the increasing labor and tax of the nation, the scale of the Jeongjagak was changed to decreasing size. Due to the improvement of drawings and annotation on a Eugwe(儀軌) at the first year of King Sunjo, the size of Jeongjagak was standardized.
In order to prevent upper extremity musculoskeletal disorders, effective keyboard selection is an important consideration. The aim of this study was to compare upper extremity muscle activity according to transverse plane angle changes during vertical keyboard typing. Sixteen healthy men were recruited. All subjects had a similar typing ability (rate of more than 300 keystrokes per minute) and biacromion and forearm-fingertip lengths. Four different types of keyboard (vertical keyboard with a transverse plane angle of 60˚, 90˚, or 120˚, and a standard keyboard) were used with a wrist support. The test order was selected randomly for each subject. Surface electromyography (EMG) was used to measure upper extremity muscle activity during a keyboard typing task. The collected EMG data were normalized using the reference contraction and expressed as a percentage of the reference voluntary contraction (%RVC). In order to analyze the differences in EMG data, a repeated one-way analysis of variance, with a significance level of .05, was used. Bonferroni correction was used for multiple comparisons. There were significant differences in the EMG amplitude of all seven muscles (upper trapezius, middle deltoid, anterior deltoid, extensor carpi radialis, extensor carpi ulnaris, flexor carpi radialis, and flexor carpi ulnaris) assessed during the keyboard typing task. The mean activity of each muscle had a tendency to increase as the transverse plane angle increased. The mean activity recorded during all vertical keyboard typing was lower than that recorded during standard keyboard typing. There was no significant difference in accuracy and error scores; however, there was a significant difference between transverse plane angles of 60˚ and 120˚ with regard to comfort. In conclusion, a vertical keyboard with a transverse plane angle of 60˚ would be effective in reducing muscle activity compared with vertical keyboards with other transverse plane angles.
We present analytical approximations for calculating the scattering and escape of non-ionizing photons from a plane-parallel medium with uniformly illuminated by external sources. We compare the results with the case of a spherical dust cloud. It is found that more scattering and absorption occur in the plane-parallel geometry than in the spherical geometry when the optical depth perpendicular to the plane and the radial optical depth of the sphere are the same. The results can provide an approximate way to estimate radiative transfer in a variety interstellar conditions and can be applied to the dust-scattered diffuse Galactic light.
The purpose of this study is to distinguish the causes of broken glass on doors or windows when it is originally kept among the remains on the floor in fire site - whether it was broken due to heating or outer power-through test and characteristics of the broken plane including the pattern on the plane. Addition to it, the study tries to find characteristics to judge the point and direction of breakdown through the analysis of glass broken by outer power. With two assumed causes - a) breakdown due to heating and b) breakdown due to outer power-3 pieces of glass plates (30cm×30cm×5mm) were tested for each case, getting the results as following: First, for the glass broken due to the change of temperature, the broken plane is of slow and smooth curve without any pattern. Second, for the glass broken due to outer power, with the impact point as the center, the glass shows breakdown of radial type and the side shows breakdown of near-perpendicular type. The far the broken piece is from the impact point, the bigger the size is. The broken piece at the impact point is of long triangle type and the two long planes of the triangle shows semi-arc with the center of breakdown point and the other plane shows opposite pattern. Third, when glass that is damaged by outer power is heated, damaged forms and side patterns of the glass that is damaged by outer power are heated and disappeared.
We analyzed fault plane solutions of the recent twenty-two earthquakes which occurred from 2004 to 2006 in the central part of the Korean Peninsula by using P- and S-wave polarities along with SH/P amplitude ratios. The fault plane solution shows that strike-slip fault is dominant here, especially for the events with local magnitude equal to or greater than 3.0. However, some events with local magnitude less than 3.0 show normal fault or strike-slip fault with normal components. In the case of strike-slip fault, its orientation is almost in the direction of NNE-SSW to NE-SW almost parallel to the general trend of faults, while the compressional axis of the stress field trends ENE to E-W. The result is almost consistent with the stress field in and around the Korean peninsula, as reported previously. We cannot give any appropriate explanations to the normal faulting events along the western offshore and inland areas whether it is related to the local stress changes or tectonically unidentified extensional structures. Thus, an extension of investigations is desirable to clarify the cause of such phenomena.
대공간 구조물은 3차원적인 힘의 흐름과 면내력에 의해 외부하중에 대한 저항 능력을 극대화 시킨 형태 저항 구조로서, 일반적인 골조와는 달리 부재에 대한 유한 변형을 동반 하므로 정적, 동적 해석에 관계없이 비선형 해석이 요구 된다. 대공간 구조물의 정확한 구조 해석을 수행하기 위해서는 기하학적 비선형 및 재료적 비선형 뿐 아니라 두 효과를 함께 고려한 비선형 해석이 필요하다. 기하학적 비선형 문제가 구조재료의 특성 및 위치에 따른 비선형을 고려하지 못하고, 구조재료의 비선형 문제가 기하학적 형상에 따른 비선형을 고려하지 못한다는 상호간의 단점을 해결하기 위하여, 본 논문에서는 유한요소법으로 기하학적 비선형을 고려한 비선형 평형방정식을 적용하고, 부재의 응력-변형률 관계를 이용하여 재료적 비선형성도 함께 고려하였다. 사용된 수치해석 기법은 불안정 경로의 해를 찾아갈 수 있는 호장법을 적용하여 하중-변위 곡선을 추적하였다. 본 연구의 수치 해석결과 제시한 평면 트러스의 비탄성 비선형 거동을 정확하고 효율적으로 예측 가능한 것으로 나타났다.
곡선보(curved beam)의 회전관성(rotatory inertia) 및 전단변형(shear deformation)을 고려한 면외(out-of-plane) 자유진동을 해석하는데 미분구적법(DQM)을 이용하여 고정-고정 경계조건(boundary conditions)과 다양한 굽힘각(opening angles)에 따른 진동수(frequencies)를 계산하였다. DQM의 결과는 엄밀해(efact solution) 또는 다른 수치해석 결과와 비교하였으며, DQM은 적은 요소(grid points)를 사용하여 정확한 해석결과를 보여주었다.
2007년 1월 20일 평창군 진부면 오대산 일대에서 발생한 오대산 지진(ML=4.8)은 천발지진(진원깊이 약 10 km)으로서 감진구역이 남한 남서부 일부를 제외한 전역에 이르렀다. 본진에 의한 최대 진도는 VI으로 VI에 해당하는 지역은 평창군 진부면, 도암면, 강릉, 주문진, 평창을 포함하는 지역으로서 강한 지진동과 함께 건물 실내외부 벽의 균열발생, 지붕의 기와나 스레트의 낙하 및 이동, 실내외 벽 타일의 떨어짐, 선반위 물체의 떨어짐, 도로의 낙석 등이 발생하였다. P파 초동극성과 SH/P 진폭비 자료를 이용한 단층면해는 본진의 경우 북북동-남남서 주향의 주향이동 단층운동을 나타내며, 2회의 여진은 남북 내지 북북동-남남서 주향의 역단층 운동이 우세함을 보인다. 전진, 본진 및 여진의 분포, 피해 지역 분포, 단층면해 등을 종합적으로 고려할 때 진앙지 부근에 우세하게 발달하고 있는 북북동-남남서 주향의 월정사단층이 기진 단층의 역할을 했을 것으로 추정된다. 여진 분포로 짐작컨대 subsurface에서의 이 단층의 파쇄 길이는 약 2 km로 판단되며, 추후 이 단층에 대한 고지진학적 조사가 필요하다.
이 논문에서는 철근콘크리트 구조물의 최적설계를 위해 기둥과 보 부재 설계 단면의 데이터베이스를 구성하고 이로부터 단면 번호와 단면 저항 능력간의 관계를 나타내는 회귀분석식을 구성하여, 직접 탐색법으로 빠르게 최적해를 검색하는 효율적인 알고리즘을 제안하였다. 설계 실무에서 가격을 고려하여 설계하기보다는 성능 최적화에 가까운 설계를 수행한다는 사실로부터 제안된 알고리즘을 이용하여 성능 최적화와 가격 최적화를 모두 수행하여 그 결과를 비교 검토하였고, 예제 구조물을 대상으로 적용성과 효율성을 검토하였다. 본 알고리즘은 목적 함수 구성시 제한 조건이 없고 전개 과정이 매우 단순하면서도 빠른 수렴성을 보이며 선택된 해가 설계 규준과 실무상의 제한 조건에 부합하므로 바로 적용 가능하다는 장점이 있다. 전체 구조물의 최적화는 개별 부재의 최적화를 통해 이루어진다.
본 논문에서는 비동질 반무한 평면에 대한 비례경계유한요소법의 식을 유도하고 수치예제를 해석하였다. 비례경계유한 요소법은 편미분 방정식을 경계방향으로는 유한요소와 같은 근사를 통해서 약화시키고 방사방향으로는 정확해를 사용하는 반 해석적인 방법으로, 방사방향으로 멱함수를 따라 탄성계수가 변화되는 반무한 평면에 대해서 관계식을 가상일의 원리에 근거하여 새로이 유도하였다. 이 과정에서 반무한평면의 거동이 Euler-Cauchy방정식을 따름을 보이고, 기존의 동질 반무한평면의 해석시 도입되던 로그모드가 비동질 반무한 평면의 해석에는 유효하지 않음을 보였다. 수치예제를 통하여 유도된 식이 타당한 거동을 보임을 증명하고 이 접근법이 실제 공학적 문제의 해결에 있어서 유용함을 보였다.
본 연구는 순수 면내모멘트를 발생시키는 선형적으로 변하는 수직응력을 받고 있는 단순지지된 마주보는 두 모서리와 자유경계를 가지는 직사각형 판의 자유진동과 좌굴의 엄밀해를 구하였다. 정현적으로 가정된 하중방향(x)으로의 변위함수는 단순지지 경계조건을 만족시키며, 평판을 지배하는 편미분 운동방정식 을 y 방향으로의 변계수를 갖는 상미분방정식으로 만든다. Frobenius법을 통하여, y방향으로의 멱급수를 가정하면 이 식을 엄밀하게 풀 수 있으며, 그 식의 합당한 계수를 구할 수 있다. 자유경계조건을 y=0과 b에 적용하면, 고유진동수와 임계좌굴모멘트를 구할 수 있는 4차의 특성행렬식이 만들어진다. 본 논문에서는 이 급수해의 수렴성이 면밀히 조사되었으며, 임계 좌굴모멘트의 수치결과와 모드형상이 주어진다. 상대적으로 정확도가 떨어지는 1차원적인 보 이론으로 구한 결과치와의 비교연구가 이루어진다. 또한 자유진동수와 모드형상 주어진다. 프와송비(v)의 변화에 따른 좌굴모멘트와 고유진동수의 변화가 도표로 주어진다.
이 연구의 목적은 면외방향으로 반복하중을 받는 철근콘크리트 벽식 교각의 지진거동을 파악하고 합리적이면서 경제적인 내진설계기준을 개발하는데 있다. 정확하고 올바른 성능평가를 위하여 신뢰성 있는 비선형 유한요소해석 프로그램을 사용하였다. 사용된 프로그램은 철근콘크리트 구조물의 해석을 위한 RCAHEST이다. 유한요소로서는 면내회전강성도를 갖는 4절점 평면 쉘요소가 사용되었다. 두께방향에 대한 철근과 콘크리트의 재료성질을 고려하기 위하여 층상화기법이 도입되었다. 재료적 비선형성에 대해서는 균열콘크리트에 대한 인장, 압축, 전단모델과 콘크리트 속에 있는 철근모델을 조합하여 고려하였다. 신뢰성 있는 실험결과와 비교를 통하여 이 논문의 제안방법이 면외방향으로 반복하중을 받는 철근콘트리트 벽식 교각의 내진성능평가에 적합한 방법임을 입증하고자 한다.
A comparative study is made on root bending fatigue performance of spur gears and plane bending fatigue performance of notched test bars. R = 0 root bending fatigue tests are made on small spur gears with critical root radius 1.0 mm. The results are compared to plane bending fatigue tests of 0.9 mm radius notched specimens. Results are presented for tests on 4%Ni/2%Cu/1.5%Mo prealloyed PM steel with addition of about 0.6% graphite. Predicted values from the test bars coincide well with the results obtained from the gear root fatigue tests.