        82.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The improvement of heat transfer in water cooling passage of lithium-ion battery is numerically studied by employing trapezoidal vortex generators. Battery Design StudioⓇ software is used for modeling electro-chemical heat generation in the battery. The conjugated heat transfer is analyzed with the commercial package STAR-CCM+ in terms of inlet flow velocities. The result shows that vortex generator enhances the convective heat transfer by developing thermal boundary layers and secondary flows in downstream, which results in reducing the average temperature of the battery by about 1℃. The heat transfer is enhanced for the whole inlet velocity, while the pressure loss sharply increases at more than inlet velocity of 0.1m/s. The optimum inlet velocity is around 0.1m/s for in terms of the heat transfer and pressure loss.
        4,000원
        83.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 부분 CFST (concrete-filled steel tube) 기둥에 대한 수치해석적 저항력 평가 방법에 대해 소개하고 있다. 기존 RC (reinforced concrete) 기둥에서 소성힌지가 발생할 것으로 예상되는 부분을 강관으로 보강함으로써 완전 CFST 기둥보다는 적은 재료를 사용하여 비슷한 휨 모멘트 저항력을 가지는 부분 CFST 기둥의 디자인 컨셉을 제시하였다. 부분 CFST 기둥에서 외부 강관과 내부 콘크리트 사이의 계면에서 거동을 수치해석적으로 모사하기 위해 개선된 부착슬립모델을 적용한 유한요소모델을 구축하고, 이중곡 률 휨-압축시험결과와 비교를 통해 타당성을 검증하였다. 검증된 수치모델을 바탕으로 매개변수 연구를 통해서 P-M 상관도를 그려 단면 조건에 따른 최대 저항력을 평가하였다. 또한, 강관 두께별로 필요 보강길이를 산출하고, 보강 조건에 따른 부분 CFST 기둥에서의 파괴메커니즘을 분석하였다.
        4,000원
        84.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PartI of this paper identified the location and size of the noise sources from the axial flow fans, and partII based on that, identified the magnitude of sound pressure from the case and the blade according to frequency in the range of 2200 Hz to 5000 Hz. The equation of Lighthill was used for calculation. Generally, when measuring noise, the analytical area was extended more than 1m from the outlet of the fan. To eliminate the effects of backflow coming from the rear of the fan, the analytical area was extended a little longer than 1m. From the results of the analysis, high noise occurs in the low frequency area, and the lower noise becomes in the high frequency area. The maximum sound pressure generated in the range of 2000Hz~5000Hz is 65dB at a distance of 1m and 82dB at the outlet of the fan. Noise of the fan mainly occurred around the blade and guide, and the noise decreased as the frequency increased between 2200Hz and 3400Hz, but the noise increased as the frequency increased between 3800Hz and 5000Hz.
        4,000원
        85.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, numerical analysis was carried out to develop low-noise axial fans, which are often used for ventilation in houses. A commercial program and the turbulence models are used for the analysis of internal fan. Proudman acoustic power model and the Curle surface acoustic power model were used for analysis. As a result, the distribution of flow velocity and pressure around the blade and guide of the fan was high, and low in the center of the fan. Noise from the inner wall of the fan case and the blade surface was the highest at the body and vane connections of the blade, and low at the center of the vane and the center of the body.
        4,000원
        86.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 원자로 1400(APR 1400) 원자력 발전소(NPP)의 원자로 격납건물(RCB) 내진성능에 대해 상이한 수치모델과 지진 주파수 성분의 영향을 평가하는 것이다. 집중 질량 막대 모델(lumped-mass stick model, LMSM)과 3차원 유한요소모델(threedimensional finite element model, 3D FEM)의 두 가지 수치 모델이 시간이력해석을 수행하기 위해 개발되었다. LMSM은 기존의 집중 질량 보-요소를 사용하여 SAP2000으로 구성하였으며, 3D FEM은 각기둥 입체-요소를 사용하여 ANSYS로 작성되었다. 저주파수 및 고주파수 성분을 고려한 두 그룹의 지진파를 시간이력해석에 적용하였다. 저주파수 지진파의 응답스펙트럼을 NRC 1.60의 설계 스펙트럼과 일치되도록 조정하여 작성하였으며, 고주파수 지진파는 10Hz ~ 100Hz의 고주파수 범위를 갖도록 생성하였다. RCB의 지진응 답은 다양한 높이에서 층응답스펙트럼으로 검토하였다. 수치해석 결과, 저주파수 지진에 의한 구조물의 FRS 결과는 두 수치 모델에 서 매우 유사한 결과를 보였다. 하지만, 고주파수 지진에 의한 LMSM의 FRS 결과는 고차 고유 주파수 영역에서 3D FEM과 큰 차이를 보였으며, RCB의 낮은 높이에서 명확한 차이를 보였다. 3D FEM이 정확한 구조물의 응답을 나타내는 것으로 가정한다면, RCB의 LMSM은 고주파수 지진에 의한 FRS 결과의 고차 고유 주파수 영역에서 일정 수준의 불일치성을 내포하고 있다.
        4,000원
        87.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 선박용 디젤엔진의 미세먼지저감 장치에 장착된 다공판 및 믹서의 형상과 배치에 따른 압력강하와 유동균일도 특성에 대한 연구를 진행하였다. 미세먼지저감 장치에 장착된 다공판 및 믹서는 미세먼지저감 장치 내의 배출가스 및 산화/환원제의 유동 균일도를 높여 배출가스 저감 성능을 높이는 긍정적인 효과와 함께 시스템의 배압을 상승시키는 부정적인 효과도 동시에 지니고 있다. 본 연구에서는 5개의 다공판, 1개의 믹서를 Case 별로 조합하여 6개의 사양에 대해서 유동해석을 통해 각각 유동균일도 및 압력 강하를 계산하였으며, 최적의 다공판 및 믹서의 형상과 배치를 선정하였다.
        4,000원
        88.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: In this study, a numerical parametric study was performed to evaluate the effect of angular velocity and weight of wheel, and density of road-bed particles on corrugation development. METHODS : Discrete element method coupled with rigid body dynamics was applied to simulate a wheel-running circular table with variations in independent parameters, such as wheel angular velocity, wheel weight, and particle density. The position profiles for travel distance from origin were compared and analyzed to confirm if the trend from numerical analysis agrees with the analytical solution. RESULTS: The angular velocity of the wheel exhibits a clear inverse relationship with the development of corrugation even though the weight of wheel does not demonstrate clear trends for both long-wave and short-wave corrugation. The density of road-bed particles is observed to have clear proportional effect on corrugation development. The movement of corrugation to the running direction, which was observed in previous research, is also observed for various conditions. CONCLUSIONS : The parametric study using discrete element method with rigid body dynamics clearly exhibits good agreement with analytical solution for initiation of corrugation. The coupled method is confirmed to supply additional information that cannot be delivered by analytical solution only.
        4,200원
        94.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Heat transfer and pressure drop of horizontal heat exchangers with different configurations and installations numerically characterized. Three different heat exchangers were used and shaped as linear, wavy, and horizontal slinky, respectively. Installation depth was set from 0.5m to 3.0m and pipe spacing was ranged from 0.3m to 2.1m. The results showed that heat transfer rate and pressure drop were increased with the increase in the installation depth and the pipe spacing. The horizontal slinky heat exchanger carried more heat compared to others due to the greater effective heat transfer surface area per installation area. In terms of a ratio of heat transfer rate to pressure drop indicating the system efficiency, the linear heat exchanger performed better than others. On the other hand, the horizontal slinky heat exchanger was the most effective with respect to a ratio of heat transfer rate to installation cost.
        4,000원
        95.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Using computational fluid dynamics (CFD), this study simulated the air supply and exhaust conditions inside KTXSancheon train cabin to analyze the airflow, velocity, temperature, and residence time distributions. Based on the analyzed airflow in the cabin, the trajectory properties of droplets with various diameters exhaled from a passenger in a specific seat were analyzed. In the train cabin, forced airflow was formed by the operation of an air conditioning unit, while air stagnation occurred through spinning vortices at the front and rear where there were no floor outlets. Droplet particles ≤36 μm in diameter were dispersed throughout the cabin following the airflow generated by the air conditioning unit. The degree of dispersion differed according to the passenger seat location. In addition, the expelled droplets were mostly deposited on the surfaces of passenger bodies, seats, and floor. The ratio of deposited droplets to suspended droplets was increased with increasing droplet size. Further, the CFD study allowed the prediction of the possibility of exposure to exhaled droplets by estimating the dispersion and deposition properties of droplets released from a passenger in a specific seat. This study can be utilized to adjust the operation of air conditioning units and encourage the installation of air-purifying units to minimize secondary infections.
        4,000원
        100.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The effect of inclination angle and attack angle on heat transfer enhancement of trapezoidal vortex generator was numerically investigated. The commercial package STAR-CCM+ was utilized to analyze the heat transfer and flow characteristics with various inclination and attack angle of vortex generator. The result shows that the optimum inclination angles are α =30°~40° in terms of the heat transfer and pressure drop. At more than 40° of inclination angle, the transverse vortex is dominant, so that the pressure drop is severe and the heat transfer is reduced. As the attack angle is increased, the transverse vortex is reduced, so that the pressure drop is improved. The optimum attack angle is β =30° because the heat transfer performance is maintained. However, more than 30° of attack angle, the heat transfer is decreasing.