The seismic performance of school buildings has been a matter of common interest socially and academically. The structural system of the school buildings is representative of the domestic low-rise reinforced concrete moment resisting frames, which apply extensively infills in their masonry walls. The masonry infilled walls are divided into full masonry infill in the transverse direction and partial masonry infill in the longitudinal direction. The masonry infilled walls are usually not included in structural analysis during the design process, but affect significantly the seismic performance because they behave with surrounding frames simultaneously during earthquakes. Many researchers have studied the effect of the masonry infilled walls, but several issues have been missed such as the increase of asymmetry by adding the full masonry infill, the size of the mean strength of the full masonry infill, and short column effect by the partial masonry infill. The issues were analytically investigated and the results showed that they should be checked at least by nonlinear pushover analysis in the seismic performance evaluation process. The results also confirm the weakness of the guideline of Korean Educational Development Institute where the seismic performance is basically assessed without structural analysis.
In recent years, the construction of high-rise buildings are promoted. According to these, there are many needs about new technologies to strengthen the building performance and high-strength steel is regarded as one of these for promoting building performance. In Korea, high-strength steels which stress are over 600MPa are on market and in aborad, super high-strength steels over 1000MPa are developing and they expected to promote the building performance. But there are still doubts about applying high-strength steel members because of size effect and worry of brittle fracture. In this reports, we propose results of performance and analysis tests for use with general steel. We propose the characteristic of high-strength steels first and next the results of performance test to show they satisfy the performance that designers expect. And last, we compare the results of test and analysis for acquire the alanysis reliability in non-linear analysis with high-strength steels.
The gas flow and heat transfer inside an EGR cooler for a diesel engine are numerically analyzed to investigate the performance of EGR cooler. The commercial code FLUENT is utilized to simulate a single spiral tube with constant wall temperature condition. The numerical analysis is performed with the variation of exhaust gas flow rates according to engine speed. The computational results agree well with the experimental results published before. The results show that the maximum error rate is about 0.6% for all operating conditions. Thus a single tube model with constant wall temperature condition is appropriate for simulating EGR cooler.
In this study, the performance characteristics of EGR Cooler applying to the current commercial vehicle was analyzed by the numerical analysis. Through the experiment the performance evaluation of EGR Cooler must need a lot of time and expenses. On the other hand, the numerical analysis has been used in many research areas as a way to reduce the cost and time. The analysis model of this study has a spiral shape tube. The exhaust gas passes through the inside of the tube. The performance of Cooler was analyzed according to the variation of gas mass flow rate. The results of analysis and experimental was confirmed that was indicating the same trend.
The paper introduces Multi-Platform Analysis (MPA) for the seismic performance of a structure controlled by Magneto-Rheological (MR) dampers and presents analytical assessment of the effect of MR damper when taking into account nonlinear behavior of the structure. This paper introduces the MR Damper Plugin that can facilitate communication between MATLAB/Simulink and a finite element analysis tool in order to account for more complex inelastic behavior of the structure with MR dampers. The MPA method using the developed MR Damper Plugin is validated with experimental results from the real-time hybrid simulation. By utilizing the proposed MPA method, the three-story RC structure controlled by MR dampers is more realistically modeled and its performance under seismic loads is investigated. It is concluded that MR damper designed for a linear structure is not effective in a nonlinear structure and can overestimate the effect of MR damper. This work is expected to overcome difficulties in the analytical assessment of structural control strategies for complex and nonlinear structures by obtaining more reliable results.
A three dimensional numerical analysis was performed to study the PEMFC performance characteristics. Operating pressure and operating temperature were selected as simulation parameters. Operating pressure was varied as 1, 2, 3, 4, and 5 atm. Operating temperature was varied as 323, 333, 343, 353, and 363 K. For a constant cell voltage condition, the maximum current density was obtained at operating pressure of 5 atm and operating temperature of 323 K. As operating pressure increases, current density increases because concentration of reactant gases increases. As operating temperature increases, current density decreases because concentration of reactant gases decreases due to high overpotential condition for the considered PEMFC.
In this paper, a three dimensional numerical analysis tool was applied to study the PEMFC performance characteristics. The porosity and electrical conductivity of GDL and CL as well as the relative humidity of anode and cathode channel gas were selected as simulation parameters. The porosity of GDL and CL was varied as 0.3, 0.5, and 0.7. The relative humidity of anode and cathode was varied as 0, 20, 40, 60, 80, and 100 percent. The electrical conductivity of GDL and CL was varied as 1, 5, 10, 50, 102, and 104 1/Ω·m. For a constant cell voltage condition, the maximum current density was obtained at GDL porosity of 0.7, anode relative humidity of 100 percent, cathode relative humidity of 60 percent, and electrical conductivity of 104 1/Ω·m for GDL and CL. As the porosity of GDL and CL increases, current density increases because reactant gases diffuse well. As the electrical conductivity of GDL and CL increases, current density increases due to increased electron transfer rate. As anode relative humidity increases, current density increases. Unlike anode, current density increases when cathode relative humidity increases from 0 percent to 60 percent. Then current density decreases when cathode relative humidity increases from 60 percent to 100 percent.
This study develops an efficient numerical algorithm to predict wave-resistance performance of a catamaran hull. The developed numerical algorithm is applied to evaluate wave-resistance performance for two different twin hull forms with a asymmetric and a symmetric mono hull. Numerical calculations and model tests are compared to validate a developed numerical algorithm adopted in the current work. Comparisons are carried out through the sinkage at the bow and stern, the trim and the wave-making resistance coefficient. Model test is performed in order to verify the numerical results. The comparative analysis study regarding hydrodynamic characteristic of different twin hull forms is worthy of application in the catamaran hull form development stage.
국내 철골모멘트골조를 이전 KBC2005 및 현 KBC2009 기준에 따라 설계한 후 비선형동적해석을 이용하여 FEMA355F의 내진성능평가 절차에 따라 성능을 평가하였다. 그 결과 비선형정적 Push-over 해석을 이용한 역량스펙트럼법과 차이가 있었다. 특히국내 철골모멘트골조는 약패널존을 가지기 때문에 비선형동적해석을 통해서만 보다 정확한 거동을 예측할 수 있었다. 국내 철골모멘트골조는 지반 조건 SB 또는 SC에 위치한다면 층수 및 R값에 관계없이 성능목표를 만족하는 것으로 나타났다. 하지만 지반 조건 SD 또는SE에 위치한다면 성능목표 만족 여부는 명확하지 않았다. 따라서 KBC2005나 KBC2009 어떤 기준을 사용하더라도 지반 조건이 상대적으로 좋다면 국내 철골모멘트골조는 내진성능을 충분히 확보하고 있다고 볼 수 있다.
본 연구는 학교 건물의 구조적 성능 평가를 통한 내진보강에 대한 연구이다. 본 연구의 목적은 학교 건물의 구조적 성능평가를 통하여 안전성과 사용성을 고려한 구조보강방안을 비교분석하고 합리적 내진 보강안을 제시하여 보다 지진에 안전한 건축물을 유지하는데 도움 이 되고자 한다. 이 목적을 위해 기존의 학교건물을 연구 대상으로 선정하여 내진성능평가를 실시하고 내진 보강안을 제시하였다. 본 연구의 방법은 기존의 철근콘크리트 학교건물을 대상으로 1차 내진 성능평가와 2차 내진 성능평가를 실시하였다. 위와 같은 방법으로 내진성능평가를 하여 그 결과를 분석하고 내진보강방안을 제시(강재댐퍼, 탄소막대보강재)하였다. 제시된 내진 보강방안을 대상 건축물에 적용하여 내진보강 전, 후의 내진성능평가를 통해 종합적인 결과를 도출 하였다.
In this study, We evaluated structural performance of SRC Column using square steel tube. the parameter is a pre-axial load for inner CFT column. ABAQUS 6.9.3 was used for analysis. The results from this study show that the pre-axial load for inner CFT column does not affect to structural performance of the SRC column using square steel tube. And, a experimental test is needed to investigate the results of this study.
Ground source heat pumps are clean, energy-efficient and environment-friendly systems. Although the initial cost of ground source heat pump system is higher than that of air source heat pump, it is now widely accepted as an economical system since the installation cost can be returned within an short period of time due to its high efficiency. In the present study, performances of ground source compound hybrid heat pump system applied to a resort building are simulated. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a resort building. If among several renewable energy sources, ground, river, sea, waste water source are chosen as available alternative energies are combined, COP of the system can be increased largely and hybrid heat pump system can reduced the fuel cost.
Kart-Racing which is called a microcosm of F1`s racing is the most basic step in the car racing. A Kart consisting of the very fundamental structure which does not include differential gear and suspension is sampler than a typical car. It is necessary to reduce the Lab time at the Kart-racing`s corner so the research investigate the Kart through check of racing condition and of driving factors about cornering. The study measured to make the kart closely factual condition which was showed the main parameters for more actual decision of kart`s dynamic characteristics and estimated the real-time data from the developed kart whose sensor was installed at all tires and which was pursued through the GPS.
이 연구는 지진하중을 받는 프리캐스트 세그먼트 PSC 교각의 지진거동을 파악하는데 그 목적이 있다. 사용된 프로그램은 철근콘크리트 구조물의 해석을 위한 RCAHEST(Reinforced Concrete Analysis in Higher Evaluation System Technology)이다. 사용된 부착 또는 비부착 텐던요소는 유한요소법에 근거하며 프리스트레스트 콘크리트 부재의 콘크리트와 텐던의 상호작용을 구현할 수 있다. 그리고 수정된 접합요소는 세그먼트 접합부의 비탄성거동을 예측할 수 있다. 동적 평형방정식의 해는 HHT(Hilber-Hughes-Taylor) 법에 의한 수치적분으로 구하였다. 제안된 해석기법은 수치예제에 대하여 입력지진파에 따른 지진거동을 비교적 정확하게 예측하였다.
수직형에 비해 비교적 가격이 저렴하고 냉난방을 동시에 할 수 있는 농업시설에 적합한 10RT 규모의 수평형 지열히트펌프 시스템을 240m2 면적의 온실에 설치하고, 이 시스템의 냉방성능을 분석하였다. 응축기 출구온도가 40℃에서 58℃로 상승함에 따라 소비전력은 11.5kW에서 15kw로 상승하였으며, 고압이 1,617kpa에서 2,450kPa로 변화하였다. 냉방성능계수는 지중온도 25.5℃에서 2.7 수준이었으며 지온이 상승함에 따라 하강하여 33.5℃에서 2.0 수준이었다. 또한 온실 내부로부터 흡수하는 열량(냉방열량)은 같은 지중온도 수준에서 각각 28.8kW, 26.5kW이었다. 가동 8시간 후 지열교환기가 설치된 60cm깊이의 지온은 14.3℃가 상승하였으며 150cm는 15.3℃가 상승하였다. 반면 지열교환기가 매설되지 않은 60cm 깊이는 2.4, 150cm 깊이는 4.3℃의 지온상승을 보였다. 열매 체유가 지열교환기를 통과한 후 평균 7.5℃의 온포가 하강하였으며, 토양온도가 평균 27.5℃ 수준에서 토양으로 방출하는 열량은 평균 46kw로 지중열교환기의 단위 길이 당 약 36.8W의 열량을 방출하는 것으로 분석되었다. 팬코일 유닛이 온실로부터 흡수하는 냉방 열량은 평균 28.2kW이었으며, 열매체유의 온도는 4.2℃ 상승하였다. 축열조내 열전달매체유의 온도가 26.0℃에서 2.0℃까지 하강하는데 3시간이 소요되었으며, 평균 축열율은 29.7kW, 총 축열량은 321MJ이었다. 또한 2.0℃까지 냉열을 축열한 후 25.4℃까지 방열되는 시간은 외기온이 평균 28.5℃일 때 4시간이었고, 총 313.0MJ의 에너지가 방열되었으며, 이때 평균 방열율은 21.7kW인 것으로 분석되었다.
구조물의 내진 성능 평가는 구조물에 가해진 지진력에 대한 변위요구와 같은 구조물의 성능 평가를 필요로 한다. 증분동적해석(IDA)은 지진하중에 대한구조물의 성능 평가를 위해 최근에 알려진 해석 방법이다. 이 방법은 구조물의 탄성 단계에서부터 항복, 파단에 이르기까지 지반가속도의 증가 수준에 따른 구조물의 전체 거동을 파악할 수 있는 방법이다. 대부분의 구조물들은 강한 지진을 받을 경우, 비선형 거동의 변형이 예상된다. 여러 가지 비선형해석법 가운데 구조물의 내진역량을 계산하기 위한 가장 정확한 방법은 비선형 시간이력해석(NRHA)이긴 하나 많은 시간과 노력이 요구되고 있다. 따라서 구조물의 비선형 거동을 보다 간편하게 예측하기 위한 정확하고 실용적인 비선형 약산해석법에 관한 연구들이 활발히 진행되고 있다. 비선형 모드중첩법(UMRHA)은 pushover곡선으로부터 구한 등가단자유도계를 비선형 시간이력해석 또는 응답스펙트럼을 이용하여 구조물의 비선형 응답을 구할 수 있는 방법이다. 직접스펙트럼해석법(DSA)은 pushover 해석으로부터 구조물의 선형 진동주기와 항복강도를 구한 다음, 반복계산 없이 비선형 응답을 직접 산정하는 약산법이다. 본 연구에서는 내진성능의 증분동적해석을 위한 비선형 약산법의 정확성과 신뢰성을 비교 검토한다.
1968년 영국의 Ronan Point 아파트에서 발생한 연쇄붕괴 이후 이에 대한 연구가 간헐적으로 진행되어 왔으며, 최근 미국의 World Trade Center 붕괴 후 연쇄붕괴에 대한 연구가 다시 활발히 진행되고 있다. 미국에서는 기존의 연구결과를 바탕으로 2003년 GSA 및 2005년 DoD에서 연쇄붕괴에 대한 설계 및 해석 지침을 제시하였다. 본 연구에서는 이러한 지침서에서 제시하고 있는 선형정적해석법과, 선형동적해석법을 사용하여 국내 설계기준에 의해 설계된 철골 모멘트저항골조에 대한 붕괴저항 성능을 조사하였다. 해석결과에 따르면 GSA 기준을 적용할 경우 횡력을 고려하지 않은 수직저항시스템은 연쇄 붕괴에 취약한 것으로 나타났으나, 지진력을 고려하여 설계된 수평저항시스템은 연쇄붕괴에 대해 안전한 결과를 얻었다. 하지만 DoD 기준에 따르면 두 시스템 모두 연쇄붕괴에 취약한 것으로 나타났다.
지진하중에 의한 구조물의 손상 및 피해는 지진에 의한 동적 하중을 고려한 구조물의 내진설계의 도입을 통하여 저감시킬 수 있으며, 이 때 내진설계 도입으로 인한 구조물의 내진성능 향상 및 그에 필요한 비용을 동시에 고려하여 내진설계 도입의 적합성을 검증해야한다. 본 연구에서는 내진성능의 확률적 평가를 위해서 지진하중과 구조물 자체에 내재되어 있는 불확실성을 고려하여 빌딩구조물의 지진취약도를 작성하였으며 시뮬레이션의 효율성을 높이기 위한 Latin Hypercube 샘플링 기법을 도입하여 해석을 수행하였다. 내진 설계 도입의 필요성 검증을 위해서는 구조물의 물리적 내진성능 이외에도 구조물의 사회적, 경제적 기능 및 가치에 대한 고려가 필요하며 이러한 요소를 고려한 의사결정해석 절차를 등가비용모델의 예를 들어 제시하였다.