검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 171

        161.
        2011.07 KCI 등재 서비스 종료(열람 제한)
        In this study, thermal environment changes for a marathon course of IAAF World Championship, Daegu 2011 were modeled to provide improvements of thermal environment, so that runners could have the maximum condition and citizens pleasant streets. The three biggest size of intersections were selected for the study. Envi-met, 3G microclimate model, were used for a thermal environment analysis and three different cases - present status, planting roadside tree scenario, and roof-garden scenario - were compared. The followings are the results of the study. 1. The highest thermal distribution were shown at 1 p.m., but there was no significant difference between a thermal distribution at 1 p.m. and that at 5 p.m. since a heat flux from buildings affects thermal distributions rather than insolation does. 2. Tree planting or adding environmental friendly factors might lead a temperature drop effect, but the effect was not significant for areas covered with impermeability packing materials such as concrete or asphalt (especally, for Site case 2) 3. The combination of tree planting and adding environmental friendly factors also brought a temperature drop effect (Site 1 and 2) and this case showed even better result if green spaces (especially, parks) were closed.
        162.
        2007.01 KCI 등재 서비스 종료(열람 제한)
        온도균열지수에 영향을 미치는 인자들은 무수히 많다. 그러나 본 연구에서는 온도균열지수에 영향을 크게 미치는 시멘트종류, 타설높이, 양생조건, 타설온도, 단위시멘트량, 재료물성치 등의 변수를 변화시키며 해석하였다. 매스콘크리트의 수화열 해석결과는 각 절점마다 나타나므로 모든 절점의 온도응력과 인장강도를 검토한 후 가장 불리한 위치에서의 온도균열지수를 찾아야 한다. 그러나 일반적으로 매스콘크리트 해석시 가장 불리하게 여겨지는 부분은 구조물의 중심부분과 구조물의 표면부분이다. 시멘트종류(대류계수)타설온도 MPC(8)MPC(14)OPC(6)OPC(8)10℃정밀식1.581.501.251.15간략식0.790.750.670.60(℃)18.919.922.524.920℃정밀식1.361.291.141.02간략식0.710.620.640.56(℃)2124.223.426.830℃정밀식1.141.061.080.95간략식0.600.550.650.58(℃)24.927.123.126따라서 본 논문에서는 Fig. 2와 같이 온도균열지수의 변동폭이 심하고 위험할 것으로 예상되는 5곳을 미리 정하고, 몇 번의 수치분석결과를 통해 각 위치별 대표절점을 상부외측표면부(A2), 기초중심부(B), 하부외측표면부(C2) 3곳으로 정하였다. 그리고 그 절점에서의 온도응력을 파악한 후 온도균열지수를 분석하였다. 상부중앙표면부(A1)는 A2 위치에서의 온도응력과 유사하지만 조금 작은 값을 가져 제외하였고, 하부중앙표면부(C1)는 다른 위치에 비해 온도균열지수가 높고, 변동폭이 작아 온도균열에 가장 유리 할 것으로 판단되어 제외하였다. 시멘트의 종류에 따라 보통포틀랜드시멘트(Ordinary Portland Cement)는 OPC로 표시하였고, 중용열포틀랜드시멘트(Moderate heat Portland Cement)는 MPC로 표시하였다. 또한, 단위시멘트량은 320,330,340kg/m3으로 나누어 각각 해석하였다. 콘크리트의 비열 및 열전도율은 일반적으로 Table2와 같이 일정한 범위를 가지므로 본 연구에서는 그 범위 중에서 MIN(열전도율2.6, 비열 1.05), MID(열전도율2.7, 비열1.15), MAX(열전도율2.8, 비열1.26)로 나누어 해석하였다.
        163.
        2006.03 KCI 등재 서비스 종료(열람 제한)
        최근들어 매스콘크리트 구조물의 시공이 증가 추세에 있다. 이러한 매스콘크리트는 수화열상승으로 온도균열이 발생할 수 있다. 온도균열을 방지하기 위하여 일반적으로 프리 쿨링, 파이프 쿨링 및 타설높이를 제한하는 방법이 사용된다. 본 연구에서는 교각 기초의 온도균열을 방지하기 위하여 열응력 검토를 실시하였으며, 이때 기초는 12m×14m의 면적과 3m 높이를 가지는 것을 모델로 하였다. 타설 높이를 제한하는 방법과 파이프 쿨링에 의한 해석결과를 비교 검토 하였다. 온도응력를 해석한 결과 지반위에 타설한 기초매트는 타설높이를 제한하는 방법과 파이프쿨링 방법에 의해 균열을 제어할 수 있다.
        164.
        2005.06 KCI 등재 서비스 종료(열람 제한)
        In order to work out statistics of environmental functions of indoor landscape plants in architectures, this study aims to conduct a simulation of how much control plants have over overheating phenomena in atria in summer, involve themselves in air current speed and maintain indoor comfort index, with a numerical analysis model. Thus, nine kinds of representative plants which are usually used for indoor environments were selected, and purified with two irrigations a day for two weeks. And then, their transpiration and photosynthesis amounts were measured three times with a photosynthesis analysis system LICO-6400 at 38℃, which is the highest temperature in the atrium in summer. The data were organized, and another three plants with similar transpiration and photosynthesis amounts were selected. The leaf area which accounts for 10% green zone rate inside the atrium was calculated, and the leaf surplus was removed. And then, the plants were left inside the atrium, and transpiration amount and temperature change were automatically measured for three hours. The maximum temperature change by transpiration of plants was found to be 2.21~2.92℃, which means 0.21~0.23℃ per every 100cm² of leaf area.It is hard to see air current change in atria as convection by plants as the change is at undetectible level with a distribution of 0.08~0.005m/s. However, if air current change is made with fans even in natural air current situations, air current becomes active inside atria as rather cold air moves upward. Therefore, if 0.5 m/s of air current change is made with upward and downward fans in atrium models, the air current speed in the entire atrium converges to the level which gives the most comfort to human.
        169.
        1997.12 KCI 등재 서비스 종료(열람 제한)
        윤성범과 이기혁(1977)의 수치모형을 이용하여 열발전소의 펌프 비상중단시 냉각수 계통에서 발생하는 서어지거동을 해석하였다. 종래에 무시되었던 기계내부계통으로 부터의 유량, 폐정공기실, 및 공기유출입구, 맨홀, 개수로 및 바다의 영향을 고려하였으며, 이들이 서어지 거동에 미치는 영향을 체계적으로 분석하였다. 특히 공기유출입구의 면적에 따른 서어지 제어효과와 공기실의 공기압 변화를 제시하여 실무에의 적용이 용이하도록 하였다.
        170.
        1997.12 KCI 등재 서비스 종료(열람 제한)
        열발전소에서 비상 가동중단으로 냉각수 배수계통에 발생하는 비압축성 부정류를 해석하는 수치모형이 개발되었다. 개발된 수치모형은 냉각수 기계내부계통, 폐정, 공기실, 관로, 맨홀, 개수로 및 바다 등에 의한 복잡한 흐름에 대해 전체적인 부정류거동을 동시에 해석할 수 있는 기능을 가진다. 수치해법으로는 leap-forg 유한차분법을 적용하였으며, 간단한 경우에 대한 모형의 검증과 함께, 종래 배수암거 하류단에 적용되덕 고정수위경계조건에 대한 검토가 이루어졌다
        171.
        1997.04 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        Natural convection in agricultural-products storage system was analysed theoretically, The storage system was modelled by Internally heated fluid saturated porous layer. Darcy's law was used to explain characteristics of fluid motion. Stability equations were obtained under the linear stability theory and transfer characteristics were modelled by the shape assumption. Based on the modelling of transfer characteristics, heat trasnfer correlations were derived theoretically.
        6 7 8 9