검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 81

        4.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Industrial wastewater often contains a number of recalcitrant organic contaminants. These contaminants are hardly degradable by biological wastewater treatment processes, which requires a more powerful treatment method based on chemical oxidation. Advanced oxidation technology (AOT) has been extensively studied for the treatment of nonbiodegradable organics in water and wastewater. Among different AOTs developed up to date, ozonation and the Fenton process are the representative technologies that widely used in the field. Based on the traditional ozonation and the Fenton process, several modified processes have been also developed to accelerate the production of reactive radicals. This article reviews the chemistry of ozonation and the Fenton process as well as the cases of application of these two AOTs to industrial wastewater treatment. In addition, research needs to improve the cost efficiency of ozonation and the Fenton process were discussed.
        5,200원
        5.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To remove phosphorus from the effluent of public wastewater treatment facilities, hundreds of enhanced phosphorus treatment processes have been introduced nationwide. However, these processes have a few problems including excessive maintenance cost and sludge production caused by inappropriate coagulant injection. Therefore, the optimal decision of coagulant dosage and automatic control of coagulant injection are essential. To overcome the drawbacks of conventional phosphorus removal processes, the integrated sedimentation and dissolved air flotation(SeDAF) process has been developed and a demonstration plant(capacity: 100 m3/d) has also been installed. In this study, various jar-tests(sedimentation and / or sedimentation·flotation) and multiple regression analyses have been performed. Particularly, we have highlighted the decision–making algorithms of optimal coagulant dosage to improve the applicability of the SeDAF process. As a result, the sedimentation jar-test could be a simple and reliable method for the decision of appropriate coagulant dosage in field condition of the SeDAF process. And, we have found that the SeDAF process can save 30 – 40% of coagulant dosage compared with conventional sedimentation processes to achieve total phosphorus (T-P) concentration below 0.2 mg/L of treated water, and it can also reduce same portion of sludge production.
        4,500원
        6.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Adsorption by granule activated carbon(GAC) is recognized as an efficient method for the removal of perfluorinated compounds(PFCs) in water, while the poor regeneration and exchange cycles of granule active carbon make it difficult to sustain adsorption capacity for PFCs. In this study, the behavior of PFCs in the effluent of wastewater treatment plant (S), the raw water and the effluents of drinking water treatment plants (M1 and M2) located in Nakdong river waegwan watershed was monitored. Optimal regeneration and exchange cycles was also investigated in drinking water treatment plants and lab-scale adsorption tower for stable PFCs removal. The mean effluent concentration of PFCs was 0.044 0.04 PFHxS g/L, 0.000 0.00 PFOS g/L, 0.037 0.011 PFOA g/L, for S wastewater treatment plant, 0.023 0.073 PFHxS g/L, 0.000 0.00 PFOS g/L, 0.013 0.008 PFOA g/L for M1 drinking water treatment plant and 0.023 0.073 PFHxS g/L, 0.000 0.01 PFOS g/L, 0.011 0.009 PFOA g/L for M2 drinking water treatment plant. The adsorption breakthrough behaviors of PFCs in GAC of drinking water treatment plant and lab-scale adsorption tower indicated that reactivating carbon 3 times per year suggested to achieve and maintain good removal of PFASs. Considering the results of mass balance, the adsorption amount of PFCs was improved by using GAC with high-specific surface area (2,500m2/g), so that the regeneration cycle might be increased from 4 months to 10 months even if powdered activated carbon(PAC) could be alternatives. This study provides useful insights into the removal of PFCs in drinking water treatment plant.
        4,300원
        8.
        2019.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Volatile organic compounds(VOCs) are toxic carcinogenic compounds found in wastewater. VOCs require rapid removal because they are easily volatilized during wastewater treatment. Electrochemical advanced oxidation processes(EAOPs) are considered efficient for VOC removal, based on their fast and versatile anodic electrochemical oxidation of pollutants. Many studies have reported the efficiency of removal of various types of pollutants using different anodes, but few studies have examined volatilization of VOCs during EAOPs. This study examined the removal efficiency for VOCs (chloroform, benzene, trichloroethylene and toluene) by oxidization and volatilization under a static stirred, aerated condition and an EAOP to compare the volatility of each compound. The removal efficiency of the optimum anode was determined by comparing the smallest volatilization ratio and the largest oxidization ratio for four different dimensionally stable anodes(DSA): Pt/Ti, IrO2/Ti, IrO2/Ti, and IrO2-Ru-Pd/Ti. EAOP was operated under same current density (25 mA/cm2) and electrolyte concentration (0.05 M, as NaCl). The high volatility of the VOCs resulted in removal of more than 90% within 30 min under aerated conditions. For EAOP, the IrO2-Ru/Ti anode exhibited the highest VOC removal efficiency, at over 98% in 1 h, and the lowest VOC volatilization (less than 5%). Chloroform was the most recalcitrant VOC due to its high volatility and chemical stability, but it was oxidized 99.2% by IrO2-Ru/Ti, 90.2% by IrO2-Ru-Pd/Ti, 78% by IrO2/Ti, and 75.4% by Pt/Ti anodes The oxidation and volatilization ratios of the VOCs indicate that the IrO2-Ru/Ti anode has superior electrochemical properties for VOC treatment due to its rapid oxidation process and its prevention of bubbling and volatilization of VOCs.
        4,200원
        9.
        2018.05 구독 인증기관·개인회원 무료
        2012년부터 강화된 총인의 농도를 준수하기 위해서는 응집에 의한 물리화학적 처리가 필수적인 후단공정이 되었으며, 현재 국내 하수처리시설 중 약 60%의 처리시설에서 총인처리시설이 설치되었다. 하지만 총인처리시설 운전에 따른 응집제 사용량이 증가하게 되었고, 이에 따라 약품 비용 및 슬러지 처리비 증가 등의 운영비가 상승하였다. 특히 분리막 공법(MBR)의 경우 막 투과수의 응집액 부족으로 인한 응집효율 저하 및 응집제의 과다 주입으로 인한 처리수질 악화 등의 문제가 발생하는 경우도 있다. 본 연구에서는 MBR 공법내에서 별도의 총인처리시설 필요 없이 생물학적 인제거를 극대화 하는 동시에 응집제 사용량을 최소화하면서 처리수의 인농도를 0.2 mg/L 이하로 유지할 수 있는 방안을 도출하고자 하였다.
        10.
        2018.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 막결합생물반응조(MBR)공법을 비롯한 하수고도처리공법에서 유입하수량의 변화에 따른 슬러지 특성 변화를 파악하고자 하였다. 일 1.5톤을 처리하는 모형실험시설에서 설계유량 대비 유입하수량을 100, 70, 40, 10%로 변 화시켜가며 이에 따른 비탈질속도(specific denitrification rate)와 비질산화속도(specific ammonia oxidation rate)의 변화를 측 정하였다. 각 공법의 폭기조에서 채취한 슬러지의 비질산화속도는 유입하수량 100% 조건에서 세 가지 공법 모두 유사한 값 (0.10 gNH4/gMLVSS/day)으로 측정되었다. 유입하수량이 70%에서 40%로 감소함에 따라 비질산화속도가 크게 감소하는 경향을 나타냈다. 비탈질속도 역시 유입하수량이 감소함에 따라 최대 50%가량 감소하였다. 유입하수량이 감소할수록 비탈질속 도와 비질산화속도가 감소하는 경향을 나타냈으나 원수의 총질소 농도와 반응조 내 미생물 농도를 고려하면 질소제거율에 영향을 미칠 정도는 아니었다. 따라서 유입하수량이 감소하는 경우에도 반응조 내 미생물 농도를 높게 유지할 수 있다면 안정적인 질소 제거가 가능할 것으로 판단된다.
        4,000원
        11.
        2017.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        하⋅폐수 처리 기술은 종래 단순 오염물질 처리에서 에너지 및 자원 절약형의 고도처리 기술로 발전되고 있으며, 공공 수역으로의 오염 물질과 유독 물질 배출을 최소화하고 설치⋅운영의 효율성을 높이기 위해 IT 및 BT와 같은 다양한 기 술을 접목한 융합형 기술로 진화하고 있다. 국내 하⋅폐수 처리기술의 발전 추이를 살펴보기 위해 등록된 특허기술을 수집⋅ 조사하여 연도별⋅부문별로 분류하여 분석하였다. 본고에서 2010년~2017년 5월 간의 관련된 특허 등록 내용을 생물학적⋅ 물리화학적 처리공정, 장치 및 기기, 소재⋅제재, 슬러지처리, 분리막, 공정제어기술 등 10개 분야의 42개 세부 영역으로 나누 어 추세를 분석했다. 총 3,356건의 특허가 등록되었으며 2013년에 638건으로 최고치를 기록한 이후 다소 감소하여 연간 3~400여 건을 유지하고 있다. 등록된 특허 총 건수는 아직 다른 국가에 비해 적지는 않으나 공정 제어 및 기기 분야, 신개념 처리 기술과 같이 세계 시장을 선도할 수 있는 첨단 기술의 특허는 타 분야에 비해 미흡한 것으로 나타났다.
        4,600원
        12.
        2017.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a model was developed to predict for Disinfection By-Products (DBPs) generated in water supply networks and consumer premises, before and after the introduction of advanced water purification facilities. Based on two-way ANOVA, which was carried out to statistically verify the water quality difference in the water supply network according to introduce the advanced water treatment process. The water quality before and after advanced water purification was shown to have a statistically significant difference. A multiple regression model was developed to predict the concentration of DBPs in consumer premises before and after the introduction of advanced water purification facilities. The prediction model developed for the concentration of DBPs accurately simulated the actual measurements, as its coefficients of correlation with the actual measurements were all 0.88 or higher. In addition, the prediction for the period not used in the model development to verify the developed model also showed coefficients of correlation with the actual measurements of 0.96 or higher. As the prediction model developed in this study has an advantage in that the variables that compose the model are relatively simple when compared with those of models developed in previous studies, it is considered highly usable for further study and field application. The methodology proposed in this study and the study findings can be used to meet the level of consumer requirement related to DBPs and to analyze and set the service level when establishing a master plan for development of water supply, and a water supply facility asset management plan.
        4,000원
        13.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Acetate, propionate, butyrate are the major soluble volatile fatty acids metabolites of fermented food waste leachates. This work investigate the effects of volatile fatty acid on the growth rate and NH4-N, PO4-P removal efficiency of mixotrophic microalgae Chlorella vulgaris to treat digested food waste leachates. The results showed that acetate, propionate and butyrate were efficiently utilized by Chlorella vulgaris and microalgae growth was higher than control condition. Similar trends were observed upon NH4-N and PO4-P consumption. Volatile fatty acids promoted Chlorella vulgaris growth, and nutrient removal efficiencies were highest when acetate was used, and butyrate and propionate showed second and third. From this work it could be said that using mixotrophic microalgae, in this work Chlorella vulgaris, fermented food waste leachates can be treated with high efficiencies.
        4,000원
        14.
        2017.05 구독 인증기관·개인회원 무료
        산업폐수 처리에서 미량오염물질(독성 유기물, 화합물, 연료 등)의 제거가 중요하다. 생물학적 처리에 의해서는 미량오염물질을 제거하기 어렵다. 따라서 본 연구에서는 분리막과 고도전기산화를 접목하여 색도, 미세입자등을 효과적으로 제거하고 막오염을 저감시키는 막결합형 고도전기산화시스템을 개발하였다. 색도는 원수 120 도(Pt-Co 색도 값)에서 처리수 20 도이하로 제거되었고, 탁도의 경우 처리수 0.1 NTU이하의 수준으로 감소하였다. 또한 막오염 저감의 성능으로 전극을 켜지않고 실험하였을때 16 kPa까지 증가하였으며 0.5 A/L전류를 공급하였을 때 5 kPa으로 유지되었다. 본 연구는 한국환경산업기술원의 환경융합 신기술 개발사업(No. 2015001640004) 연구결과의 일부이다.
        15.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        담체가 투여된 침지형 막결합 연속회분식 반응기(SMSBR)를 사용한 하수의 고도처리에서 담체가 여과성능과 제 거효율에 미치는 영향을 조사하였다. 담체는 반응기 부피 기준으로 10% 투여하였고, 담체와 분말활성탄을 첨가하지 않은 반 응기, 분말활성탄(10 g/L)만을 첨가한 반응기 및 담체와 분말활성탄을 모두 첨가한 반응기를 대조군으로 하였다. COD, T-N 및 T-P에 대한 제거효율은 담체 및 분말활성탄 첨가 유무에 따라 큰 차이가 없었다. 그러나 담체를 첨가하지 않은 경우 막간 차압(TMP)은 급격히 증가하였으나, 담체를 첨가한 경우에 막간차압은 매우 서서히 증가하였다. 담체를 투여한 SMSBR를 사 용하여 하수를 고도처리 할 때, 91일 이상의 운전기간 동안 막 세정 없이 운전이 가능하였다. 담체만을 투여한 경우, 운전 80 일 경과 이후의 COD, T-N 및 T-P 평균 제거율은 각각 95.0, 69.3% 및 51.4%이었다.
        4,000원
        16.
        2016.05 구독 인증기관·개인회원 무료
        수온 상승에 따른 조류 등 이취미 물질의 증가, 미량 유해물질의 검출로 인해 기존 여과 공정으로 시민들의 수질 기대조건을 충족할 수 없기 때문에 오존+활 성탄 등의 고도정수처리 공정의 도입이 활성화되었으며, 이미 대도시, 광역단위 에는 고도정수처리 공정 도입이 완료된 상황이다. 대부분의 국내 정수장의 여과 공정은 급속 모래여과 공정으로 구성되어 있으며, 10년간 막여과 공정이 등장하여 여과 공정에 따른 후단 오존+활성탄 공정에 미치는 영향을 파악하는 것이 필요하다고 판단되었다. 서울시 Y 정수장에 설치된 고도정수처리 파일럿 플랜트 를 활용하여 고도정수처리 공정에 모래여과수와 막여과수가 유입되었을 경우 수질 및 제거율의 변화와 활성탄 표면 변화를 관찰하였고 이를 통해 막여과 정수처리 공정 도입 필요성을 검토하였다.
        17.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The characteristics of filter/adsorber granular activated carbon (F/A GAC) were investigated by measuring various parameters, which include surface area, pore volume, abrasion number, floater, and water-soluble ash. The correlation between parameters was also evaluated. Moreover, rapid small-scale column test (RSSCT) was conducted for adsorption characteristics. Thirteen F/A GAC were tested, and the average values of abrasion number and water-soluble ash were 88.9 and 0.15%, respectively. F/A GAC with the larger external surface area and greater mesopore volume had the lower abrasion number, which indicated that it was worn out relatively easily. Water-soluble ash of coconut-based GAC (about 2.6%) was greater than that of coal-based GAC (less than 1%), and the pH of solution was increased with GAC, which had the higher water-soluble ash. On the other hand, floater of thirteen F/A GAC was divided as two groups, which one group had relatively higher floater (2.7~3.5%) and the other group had lower floater (approximately 0.5%). The results of RSSCT indicated that coconut-based GAC (i.e. relatively higher water-soluble ash) had less adsorption capacity. Moreover, adsorption capacity of coal-based GAC with larger surface area and greater mesopore volume was superior to others.
        4,000원
        18.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated the effect of a co-culture of Scenedesmus dimorphus and nitrifiers using artificial wastewater on the removal of ammonium, nitrate and phosphate in the advanced treatment. To test the synergistic effect of the co-culture, we compared the co-culture treatment with the cultures using S. dimorphus-only and nitrifiers-only treatment as controls. After 6 days of incubation, nitrate was removed only in the co-culture treatment and total amount of N removal was 1.3 times and 1.6 times higher in the co-culture treatment compared to those in the S. dimorphus- and nitrifiers-only treatments, respectively. In case of total amount of P, co-culture treatment removed 1.2 times and 12 times more P than the S. dimorphus -and nitrifiers-only conditions, respectively. This indicates that the co-culture improved removal rates for ammonium, nitrate, and phosphate. This further implies that there was no need for denitrification of nitrate and luxury uptake of P processes because nitrate and phosphate can be removed from the uptake by S. dimorphus. In addition, co-culture condition maintained high DO above 7 mg/L without artificial aeration, which is enough for nitrification, implying that co-culture has a potential to decrease or remove aeration cost in the wastewater treatment plants.
        4,000원
        19.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Microalgae is known as one alternative energy source of the fossil fuel with the small size of 5 ~ 50 µm and negative charge. Currently, the cost of microalgae recovery process take a large part, about 20 - 30% of total operating cost. Thus, the microalgae recovery method with low cost is needed. In this study, the optimum current for Scenedesmus dimorphus recovery process using electrocoagulation techniques was investigated. Under the electrical current, Al metal in anode electrode is oxidized to oxidation state of Al3+. In the cathode electrode, the water electrolysis generated OH- which combine with Al3+ to produce Al(OH)3. This hydroxide acts as a coagulant to harvest microalgae.Before applying in 1.5 L capacity electrocoagulation reactor, Scenedesmus dimorphus was cultured in 20 L cylindrical reactor to concentration of 1 OD.The microalgae recovery efficiency of electrocoagulation reactor was evaluated under different current conditions from 0.1 ~ 0.3 A. The results show that, the fastest and highest recovery efficiency were achieved at the current or 0.3 A, which the highest energy efficiency was achieved at 0.15 A.
        4,000원
        20.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study assessed the removal efficiency of NOM which is known as the precursors of DBPs in advanced water treatment using the ceramic membrane filtration, introduced the first in the nation at the Y water treatment plant (WTP). It is generally well-known that the removal of NOM by MF Membrane is very low in water treatment process. But, the result of investigation on removal efficiency of NOM in advanced water treatment using the ceramic membrane was different as follows. The removal rate of organic contaminant by the ceramic membrane advanced water treatment was determined to be 65.5% for the DOC, 85.8% for UV254, and 77 to 86% for DBPFP. The removal rate of pre-ozonation was found to be 6 to 15% more effective compared with the pre-chlorination. The removal rate of DOC and UV254 in biological activated carbon(BAC) process was over 50% and 75%, respectively although the rate was decreased 10 ~ 20% according to analysis items in converting from GAC to BAC.
        4,000원
        1 2 3 4 5