검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 91

        1.
        2023.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For fast-built and safe precast concrete (PC) construction, the dry mechanical splicing method is a critical technique that enables a self-sustaining system (SSS) during construction with no temporary support and minimizes onsite jobs. However, due to limited experimental evidence, traditional wet splicing methods are still dominantly adopted in the domestic precast industry. For PC beam-column connections, the current design code requires achieving emulative connection performances and corresponding structural integrity to be comparable with typical reinforced concrete (RC) systems with monolithic connections. To this end, this study conducted the standard material tests on mechanical splices to check their satisfactory performance as the Type 2 mechanical splice specified in the ACI 318 code. Two PC beam-column connection specimens with dry mechanical splices and an RC control specimen as the special moment frame were subsequently fabricated and tested under lateral reversed cyclic loadings. Test results showed that the seismic performances of all the PC specimens were fully comparable to the RC specimen in terms of strength, stiffness, energy dissipation, drift capacity, and failure mode, and their hysteresis responses showed a mitigated pinching effect compared to the control RC specimen. The seismic performances of the PC and RC specimens were evaluated quantitatively based on the ACI 374 report, and it appeared that all the test specimens fully satisfied the seismic performance criteria as a code-compliant special moment frame system.
        4,000원
        2.
        2023.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        현장에 적용하는 콘크리트 강도가 증가함에 따라 초고성능 콘크리트의 적용 분야가 넓어지고 있다. 초고성능 콘크리 트에는 강섬유를 일반적으로 사용하고 있지만, 이를 대체하기 위해 다양한 섬유를 연구에 적용하고 있다. 대표적으로 슈퍼섬유 라고 알려진 아라미드 섬유가 있다. 본 연구에서는 초고성능 콘크리트의 특성이 구조물 보수보강 및 내진보강에 적용하기에 적 합하다고 판단하여, 슈퍼섬유 중 하나인 파라아리미드 섬유와 조합한 복합섬유를 혼입한 초고성능 콘크리트를 보-기둥 접합부에 내진보강재로 활용하여 특성을 분석하였다. 초고성능 콘크리트의 내진보강 효과를 확인하였으며 내진상세를 적용한 실험체와 유사한 거동을 확인하였다. 초고성능 콘크리트의 높은 강도로 인해 기존 콘크리트가 파괴되는 양상이 나타나 초고성능 콘크리 트의 보수보강 효과를 모두 발휘하지 못하고 있어 추가 연구를 통해 최적의 보강단면을 설정한다면 내진보강재료로 활용할 수 있을 것으로 판단된다.
        4,000원
        3.
        2023.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study presents a dry precast concrete (PC) beam-column connection, and its target seismic performance level is set to be emulative to the reinforced concrete (RC) intermediate moment resisting frame system specified in ACI 318 and ASCE 7. The key features include self-sustaining ability during construction with the dry mechanical splicing method, enabling emulative connection performances and better constructability. Test specimens with code-compliant seismic details were fabricated and tested under reversed cyclic loading, which included a PC beam-column connection specimen with dry connections and an RC control specimen. The test results showed that all the specimens failed in a similar failure mode due to plastic deformations in beam members, while the hysteretic response curve of the PC specimen showed comparable and emulative performances compared to the RC specimen. Seismic performance evaluation was quantitatively addressed, and on this basis, it confirmed that the presented system can fully satisfy all the required performance for the intermediate RC moment resisting frame.
        4,000원
        5.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As earthquakes continue to occur in Korea in recent years, seismic evaluation and retrofit of existing school buildings have been carried out. Many domestic school buildings were built using or referring to standard drawings. Therefore, if the overall structural characteristics of a school building can be known first based on standard drawings, it can be provided as valuable data for detailed seismic evaluation. For this reason, this study investigated the weak structural components and failure modes by comparing the strength of beams, columns, and joints constituting standard school buildings constructed in the 1980s. The evaluation was performed for different types of standard drawings and different material strengths. The results showed that the joint was mainly the weakest due to the eccentricity, and the failure modes were partially changed depending on the material strength.
        4,000원
        6.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, two full-scale gravity load-designed reinforced concrete corner beam-column joints were tested by being subjected to uniand bi-directional cyclic lateral loading. The test variable was loading type: uni- or bi-directional loading. To investigate the effect of the loading type on the cyclic behavior of joint specimens, damage progression, force-deformation relation, contribution of joint deformation to total drift, joint stress-strain response, and cumulative energy dissipation were investigated. The test data suggest that bidirectional loading can amplify damage accumulation in the joint region.
        4,000원
        7.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To study the seismic resistance of the shear capacity of the RC beam-column joints of two-story and four-story RC buildings, sample buildings are designed with ordinary moment resisting frame. For the shear capacity of joints, the equations of FEMA 356 and NZ seismic assessment are selected and compared. For comparison, one group of buildings is designed only for gravity loads and the other group is designed for seismic and gravity loads. For 16 cases of the designed buildings, seismic performance point is evaluated through push-over analysis and the capacity of joint shear strength is checked. Not only for the gravity designed buildings but also for seismic designed buildings, the demand of joint shear is exceeding the capacity at exterior joints. However, for interior joint, the demand of joint shear exceeds the capacity only for one case. At exterior joints, the axial load stress ratio is lower than 0.21 for gravity designed buildings and 0.13 for seismic designed buildings.
        4,200원
        8.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        우리나라는 지진으로부터 안전한 국가라는 인식이 형성되었으나 최근 경주와 포항 지진에 의해 발생된 구조물 피해로 구조물 안전성 확보를 위한 관심이 증가하고 있다. 국내 중저층 건축물에 다수 적용되고 있는 철골 모멘트 골조는 기본적인 내진성능을 보유하고 있지만 보-기둥 접합부의 소성변형으로 인한 취성파괴로 다양한 문제를 발생시킨다. 최근에는 이러한 문제를 해결하기 위해 구조물에 상온에서 잔류변형으로부터 원형복원이 가능한 초탄성 형상기억합금의 활용에 관한 연구가 진행되고 있다. 따라서 본 연구에서는 소성변형이 집중되는 보 플랜지 부재에 초탄성 형상기억합금 보강판을 활용한 보–기둥 접합부에 대하여 실험을 통한 실질적인 내진성능을 평가하고자 한다.
        4,000원
        11.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        ACT Column은 기존 CFT 기둥보다 얇은 강판으로도 동일한 구조적 성능을 발휘할 수 있으며, 콘크리트의 구속효과와 강관의 항복 후 좌굴응력의 향상을 기대할 수 있다. ACT Column은 보-기둥 접합부에 외다이아프램을 사용한 접합상세가 적용된다. 그러나 ACT Column 외부에 콘크리트가 피복되는 SRC 타입에서는 외다이아프램을 사용한 접합부의 적용이 난해하다. 그래서 ACT Column의 외부에 수직 스티프너와 수평 스티프너를 사용한 접합상세를 제안하였다. 본 논문에서는 제안상세를 대상으로 단순인장실험을 통해 성능검증을 수행하였다. 실험체는 현장에 사용량이 많은 크기의 ACT Column 으로 2개의 실험체를 제작하였다. 보 플랜지와 보 플랜지의 양측부에 부착된 윙플레이트를 통해 보 플랜지의 단면 내력이 링다이아프램으로 전달되는 명확한 응력전달매커니즘을 나타내었으며, 보 플랜지 전단면이 소성화되어 파괴되었다. 윙플레이트의 크기가 클수록 하중전달량이 증가하였으며, 제안한 접합상세의 강도평가식을 제시하였다.
        4,200원
        12.
        2018.04 구독 인증기관 무료, 개인회원 유료
        As buildings are becoming larger, demand for large-scale composite columns for heavy load is increasing. Welded built-up CFT column (ACT Column I) previously developed by authors of this study is structurally stable and economical. Characteristic of welded built-up CFT column is that there is a limitation of cross-sectional size and application of external diaphragm connection to ensure continuity of rib. Then, composite mega column (ACT Column II) was developed to improve limit of cross-sectional size. Composite mega column has a closed cross section like welded built-up CFT column, but thick plate is inserted between cold-formed steel to expand cross section size. However, when external diaphragm connection is applied to composite mega column, amount of steel is increased greatly and interference with finishing material occurs. In this study, internal diaphragm connection is applied through characteristic of composite mega column to which beam flange or stiffener can be attached to plate. In order to analyze this, simple tensile experiment of composite mega column connection with T-shaped stiffener was performed.
        3,000원
        13.
        2018.04 구독 인증기관·개인회원 무료
        Unlike column-to-beam connections in reinforced concrete frames, column-to-beam connections are generally of the same type. Vertical load (D.L + L.L) and horizontal load (wind load, seismic load) are not the same in the upper and lower flange stress history. In the case of beams bonded to synthetic CFT columns, the tensile force is transmitted through the steel pipe column, and the compressive force is transmitted to the filled concrete, so the seismic performance is excellent even if the column has a relatively thin cross section. Also, in case of beam the composite CFT column, tensile force is taken by the steel pipe column, and the compressive force is caught by the inner concrete, and the shape of the column joint can be changed. In this study, the stress distribution of buildings is investigated according to the size and characteristics of the building, and the load history of the upper and lower flanges according to the building type is checked to show the structural possibility of the Asymmetric Diaphragms joint.
        14.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As buildings are becoming larger, demand for mega-sized composite columns (over 1-meter diameter) is increased. We have developed and commercialized welded built-up CFT column (ACT Column I) since 2005 which are structurally stable and economical using cold-formed steel with rib. However, there has a limit in size of cross section (618˟618mm) by a fabrication facilities. And due to characteristics of closed cross section, there has a limit to construction of connection of moment frame. Composite mega column (ACT Column II) has same concept of forming closed cross section. But in order to enlarge cross sectional size, thick plate is inserted between cold-formed steels. Since composite mega column can control thickness and width of thick plate, steel or composite beams can be directly attached to the connection. In this study, we propose strength formula of composite mega column to beam connections with T-shaped stiffener as internal diaphragm and verified through finite element analysis and simple tensile experiment.
        4,000원
        15.
        2017.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To investigate the cyclic characteristics of the retrofitted exterior joints of RC frame with haunch, 70% scaled 6 beam-column exterior joint subassemblies were designed according to design guideline according to 1988 and tested with cyclic loading up to 3.5% story drift ratio. During the experiments axial forces are applied to columns to simulate gravity load. Experimental results shows that the strength of retrofitted specimens was increased steadily until 2.5% story drift ratio and their strengths increased more than 1.7 times of the non-retrofitted in case that main bar was bent away from exterior joint. The joint strength and effective stiffness of the retrofitted specimen was increased and results in more deformation capacity compared to the non-retrofitted.
        4,000원
        16.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When reinforcing an existing reinforced concrete beam-column building with a precast concrete panel, special connection between the PC member and the RC member is required to solve the time dependent deformation of the RC member and to receive the large shear forces. The aim of this study is to obtain the shear strength of upper connection between the existing RC beam-column and infilled PC wall panels in experimentally and theoretically. Thus, the static shear loading tests were conducted on the 6 specimens with the plate connection. Shear failure was resulted from the weakest portion of interior PC panel, exterior RC, and the connection, when the PC portion which located at the center of specimen was pulled upward from the bottom. T he experimental result was compared with analytical result from ACI 318M-14 Chapter 17 for the shear strength of post-installed anchor and PCI Handbook 7th edition 6.8 Structural Steel Corbel (PCI Design Handbook 7th edition, 2010) for the strength of cast-in H-beam. The analytical and experimental results show final failure at the same location. The failure loading of experiment showed larger than average 6% to that of the analysis.
        4,500원
        17.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Behavior of RC(Reinforced-concrete) beam-column connections has been subjected to the earthquake loading has been determined by shear and attachment mechanism. However, since the shear and attachment are very fragile for cycle loadings. Through occurring plastic hinges at the beam, the column and the connection should remain elastic condition and the beam should dissipate the energy from the earthquake. This study was investigate on the seismic performance of 6 RC beam - column connections built with the high strength reinforcements (700MPa) based on design and detailing requirements in the ACI 318-05 Provision and KCI-07 appendix Ⅱ. This is aimed to evaluate the effect of the high-strength reinforcements as used the beam-column connection members. The main comparisons were the seismic performance of the connections affect the seismic performance in terms of strength, stiffness and ductility, joint shear stress-strain. A total of 6 beam-column specimens were built with a 1/2 scale and subjected to the cyclic loadings. Main design considerations were the area of the longitudinal reinforcements of the beam and details of the beam-column joint designed based on the seismic code. Cyclic test results are given and recommendations for the usage of high strength reinforcements for the seismic design is provided.
        4,000원
        19.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근, 모듈러 구조 시스템은 공기를 단축시킬 수 있는 장점으로 인해 건설 현장에 적용되고 있다. 모듈러 구조시스템은 단위 모듈로 구성되며, 모듈과 모듈의 볼트접합을 위해 보-기둥 접합부에 개구부를 가공하게 된다. 일반적으로 모듈러 구조시스템은 기존 철골모멘트골조와 유사한 하중전달체계를 가지는 것으로 가정하여 설계된다. 이와 같은 설계 가정의 타당성을 확보하기 위해, 단위 모듈의 보-기둥 접합부에 대한 회전 성능이 파악되어야 한다. 본 연구에서는 개구부의 구조적 영향이 고려된 접합부의 회전성능을 파악하기 위해 유한요소해석을 수행하였다. 해석결과 단위모듈은 충분한 변형능력을 가지고 안정적인 이력거동을 하는 것으로 나타났으며, 단위모듈의 접합부는 부분강접 접합부로 분류되었다. 또한 본 연구에서는 단위모듈의 비선형 골조 해석을 위한 간단한 스프링 모델을 개발하였으며, 단위 모듈의 비선형 이력 거동을 구현하기 위해 Ramberg-Osgood 이력 모델을 제시하였다.
        4,000원
        20.
        2014.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study presents an experimental study of the structural behavior for steel plate-concrete column-to-steel girder connections. Experiments were carried out to investigate the moment-rotation characteristics, failure behavior and ultimate moment capacity of these connections. The results of this experimental study involving three welded moment-resisting connections subjected to cyclic loading are presented. The specimens were fabricated at full scale to evaluate their hysteretic behavior. A description of the test specimens, the details of the joint, the test system and the testing methods are described. The test results showed that the structural behavior of these composite connections was influenced by the connection details.
        4,000원
        1 2 3 4 5