검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 16

        1.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to identify and assess key parameters affecting greenhouse gas emissions and odor intensity at a naturally ventilated dairy farm. Measurement data of greenhouse gases (CO2, CH4, N2O), odorants (NH3 and H2S), and meteorological data (wind speed, temperature, relative humidity, and solar radiation) were posited as the parameters influencing those emissions. Carbon dioxide and methane emissions correlated well to CO2-equivalent emissions and the contribution of carbon dioxide emissions (R2=0.9181) was greater than that of methane emissions (R2=0.8854). Hydrogen sulfide emissions were highly correlated with odor intensity (R2=0.9989), but the contribution of ammonia emissions to odor intensity was not significant (R2=0.0081). No correlation among CO2-equivalent and odor intensity emissions and meteorological parameters was observed. In this study, the relationship between emissions of greenhouse gases and odor intensity in a naturally ventilated dairy barn mainly depended upon carbon dioxide and hydrogen sulfide emissions. The results in this study will be helpful in the mitigation planning of greenhouse gases and odor in animal feeding operations (CFOs).
        4,500원
        2.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We used three gas sensors to monitor hydrogen sulfide, ammonia, and volatile organic compounds (VOCs), which were frequently emitted from environmental facilities, such as municipal wastewater treatment, livestock manure treatment, and food waste composting facilities. Two electrochemical (EC) sensors for detecting hydrogen sulfide and ammonia, and a photoionization detector (PID) sensor for detecting VOCs were characterized in this study. The performance of their linearity by concentration levels, lower detection limit (LDL), repeatability, reproducibility, precision, and response time were tested under the laboratory condition. The linearity according to concentration levels were favorable for all three sensors with high correlation coefficients (R2 > 0.98). The ammonia sensor showed the highest LDL (18.6 ppb) and the hydrogen sulfide and VOC sensors showed 22.3 ppb and 26.7 ppb of LDL, respectively. The reproducibility and precision were favorable for all three sensors, indicating a lower relative standard deviation (RSD) than 0.9% in the reproducibility test and 7.2% in the precision test. The response times to reach target concentration were varied from 1 to 12 minutes. The ammonia sensor needed 12 minutes of response time at 1 ppm target the NH3 concentration and the hydrogen sulfide and VOC sensors needed less than 2 minutes of response time.
        4,200원
        3.
        2017.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        It is necessary to develop a device for the design of wet scrubber with a more efficient deodorization performance in order to enhance the odor reducing effect of the wet scrubber. Therefore in this study, the superiority of the new wet scrubber with the centrifugal separation function different from the conventional wet scrubber was analyzed by the computational fluid dynamics. From CFD analysis, the pressure and velocity distribution, the peak vorticity, the retention time and the flow uniformity were calculated and compared with the performance characteristics of the centrifugal separator. As the results of CFD analysis, the peak vorticity and retention time of the gas flow were increased about 22% and the flow uniformity was improved about 7.2% by the centrifugal separator. Therefore the centrifugal separator in the wet scrubber will improve the deodorizing effect and the cleaning condition of the gas.
        4,000원
        4.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was carried out to investigate the response characteristics of a hydrogen sulfide electrochemical gassensor for several wastewater odors. At first, it was found that bubbling sampling method was superior toheadspace sampling method in terms of sensor sensitivity. High correlation between odor concentration and sensorresults was shown for two wastewater which were r=0.977 for food-waste recycling wastewater and r=0.997for food industry wastewater. On the other hand, no correlation (r=0.258) was found for plating wastewater,because hydrogen sulfide was not the main odorant for that.
        4,000원
        5.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The characteristics of odor generation with the production of resources by utilization of methane gases in landfill sites was investigated, and the effect of making resources with landfill gases on the reduction of odor was analyzed in recent years. The greenhouse gas was estimated to reduce from the range of 1,334,940~209,875 tCO₂e with the period of 2008~2017, and the effective odor was diminished with considerable amount. The more effective methods of odor removal with the utilization of waste gases were estimated by studies of similar cases to acquire standard methods of making energy resources by waste gases.
        4,000원
        6.
        2011.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, odor and white smoke emitted from textile industry has emerged as a social problem. Most of pollutants from textile industry is due to the emissions from tenter facility, and in many case wet scrubber is widely used for treating this waste gas from tenter facility. However, it is still difficult to improve the environment of textile complex because of low treatment efficiency. For this reason, we carried out the EFC (Electric Fume Collector) pilot test (50 CMM) for removing odorous substances from waste gas emitted from tenter facility. EFC is a kind of wet electrostatic precipitator. As a result of this study, pollutants and white smoke were eliminated effectively and quite large amounts of oil could be recovered.
        4,000원
        7.
        2011.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was carried out to suggest a realtime evaluation system for the odor adsorption efficiency with electrochemical sensors. As the results of the experiments for the realtime evaluation system, the correlation coefficient between the sensor signals and the hydrogen sulfide concentration was relatively good, 0.9920 and 0.8340, respectively. The relative standard deviation of three replicative experiments for the adsorption amount in the conditions of 0.5 g and 1.0 g of adsorbent was 6.97% and 3.49%, respectively. This study would contribute the realtime evaluation of odor control efficiency to overcome the limitations of olfactory method and instrumental analysis in terms of cost and technology.
        4,000원
        8.
        2006.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The application of gas sensors for the measurement of environmental odor was investigated. The test chamber systems were consist of three parts, as it were, sample injection, odor sensing and data process parts. Four type of sensors were tested with regard to sensor performance like baseline stability, sensitivity and reproducibility to H₂S, CH₃SH, NH₃, and (CH₃)₃N gases. As the results, two kinds of sensors were content with the circuit conditions used in this study. In addition, the influence of relative humidity to the selected two types sensors was tested. The [mal sensor, which was appeared to be the most stable sensor against relative humidity, was selected, and applied practically to measure the real odor from the manure odor source.
        4,000원
        11.
        2017.05 서비스 종료(열람 제한)
        현재 국내 생활폐기물 고형연료화 시설은 SRF 생산에 초점을 맞춰 생물할적 처리공정이 결여된 MT 시설의 형태로 도입되었는데 이로 인해 설계 운전범위보다 높은 함수율의 생활폐기물 반입시에 선별 효율 감소로 폐기물 반입량 대비 30~45%의 비율로 잔재물이 발생하고 있다. 이런 잔재물은 함수율 40% 이상을 보이고 있어 직매립시에서 오염부하를 증가시키고, 또한 매립에 따른 처분비용 발생으로 전체 시설 운영비의 약 20%를 차지하고 있는 실정이다. 매립지 부하 경감 및 고형연료화 시설의 운영비 저감을 위해 발생 잔재물을 재활용 할 필요가 있는데 양 및 질적인 측면을 볼 때, 함수율을 떨어뜨린 후 선별하게 되면 추가적인 SRF를 회수할 수 있다고 판단하여 잔재물의 함수율 저감을 위해 생물학적 처리공정인 Bio-drying을 적용하였다. 이는 폐기물 내 생분해성 유기물질이 미생물에 의해 호기성 분해시 발생하는 열을 이용해 폐기물의 수분을 건조시키는 방법으로 건조과정에서 자연건조 대비 다량의 배가스(악취 포함)를 배출하게 된다. 이에 본 연구에서는 생활폐기물 잔재물(저품위 혼합폐기물)에 대해 Bio-drying으로 건조하는 과정에서 발생하는 악취 특성 분석 및 해당 악취에 대해 약액세정과 활성탄이 적용된 복합 탈취설비의 성능을 확인하고자 하였다.
        12.
        2015.11 서비스 종료(열람 제한)
        우리나라에서는 매몰지 가축사체의 유기물 분해 특성, 침출수 처리, 지하수, 토양의 환경영향, 악취물질, 발생가스, 사체 분해정도 등 신뢰성 있는 자료 확보가 필요한 실정이다. 또한, 가축 매몰지로 인한 2차 환경오염 발생 가능성에 대한 언론 및 국회에서의 문제제기 등 환경영향 저감 방안 필요성, 가축 매몰지의 사체분해와 관련된 ‘용도제한 3년’ 의 적정성 여부, 매몰지 조기안정화를 위한 국내의 환경적 특성에 맞는 자료의 확보, 매몰지 사후관리계획 수립을 위한 안정화 방안, 매몰지 설계 및 환경관리지침 개선, 악취조사항목 설정을 위해 자료 확보가 필요하다. 이에 본 연구에서는 돼지와 소의 사체를 매몰하여 우리나라에서 가장 넓게 분포되어 있는 사양질 토양과 식양질, 사질 토성별로 파일럿 규모 가축 매몰지 5기를 연구단지내 설치하여 약 3년(2012.2∼2015.2) 동안 매몰사체의 발생가스 농도변화, 악취물질 등을 조사하여 악취조사항목 설정 등 가축 매몰지역 환경조사지침 등 개선방안을 제시하고 구제역으로 인한 소와 돼지의 살처분 매몰지에서 시간 경과와 매몰지 토양의 성상에 따라 어떤 악취물질이 발생하는지, 발생농도는 어느 정도인지 모니터링하여 향후에 발생할 수 있는 민원발생에 대비하기 위한 기초자료를 제시하고자 한다. 분석결과에서는 토양특성과 매몰 가축의 종류에 따라 배출되는 악취물질의 농도가 뚜렷한 경향을 나타내지 않았다. 대부분의 지점에서 Sulfurs(5종)의 농도가 높았으며, 다음으로는 Ketones(7종), Aromatics(4종), Aldehydes(5종), Alchols(8종) 순으로 검출되었다. 이후 시간이 지남에 따라 후기 시료에서는 Sulfurs(5종)의 농도가 급격히 증가하여 조사 대상시료 전체농도의 90% 이상을 차지하는 것으로 나타났다.
        13.
        2015.11 서비스 종료(열람 제한)
        염색업종에서 대부분의 대기오염물질(악취)를 발생시키는 설비는 크게는 텐터시설과 코팅시설이며 특히 텐터시설에서는 고농도의 고점성 악취유발물질인 오일미스트가 다량 배출되고 있다. 코팅시설을 운영하는 업체의 수는 전체 염색업체 중 10% 미만이지만, 염색업체 중 70% 이상은 텐터시설을 보유하고 있으며 각 지역의 염색 산단의 악취문제의 가장 큰 원인되는 설비가 텐터시설이다. 텐터 공정은 염색한 원단을 건조 및 다림질(열처리)하여 섬유의 질을 향상시키는 공정으로써 섬유 유연제, 대전방지제, 발수제등의 약품이 사용되어 진다. 또한 고온에서의 텐터기기의 마모를 방지하기 위한 윤활유를 사용하고 있으며 이러한 약품들은 텐터 공정 중 고온으로 인해 기화된다. 기화된 미세한 오일미스트 등과 같은 가스상 악취물질 형태로 배출되게 되며 민원의 발생원인이 되나 현재 뚜렷한 해결책이 없는 실정이다. 본 연구에서는 섬유산업 사업장내에서 주된 악취발생 공정인 텐타 공정에서의 건식전기집진시설을 이용한 오일미스트 회수 및 효율적인 악취저감 기술을 제안하고자 한다. 본 연구에서는 건식전기집진 원리를 이용한 30 CMM (m³/min)급 pilot-scale을 실제 염색사업장에 적용하여 텐터시설 후단에서 발생하는 배출가스의 악취를 제거하는 테스트를 진행하였다. 배출가스내 복합악취, VOCs 분석은 공인분석기관을 통한 측정하였으며, 시간당 오일회수량 무게와 석유시험범에 의한 총발열량을 분석 하였다. 대상 섬유 가공업체는 대구 성서공단에 위치한 H사이며 주생산품이 중동지역 남성 전통의상 로브직물, 폴리에스테르(polyester)으로 염색기기 래피트 연속축소기, 카렌다, 텐터 3대 등 연간 400만 야드 이상의 직물을 생산하는 사업장이다. 상기의 pilot-scale 건식전기집진시설을 활용한 염색산업 사업장내 주된 악취 원인 텐터공정 배출가스중의 복합악취 제거효율은 70% 정도로 높은 효과를 얻을 수 있었다. 이는 주된 악취유발물질인 오일 미스트 제거에 따른 효과로 시간당 720 g/m³・hr의 오일을 회수 할 수 있었다. 오일을 회수함으로써 대기중으로의 오염물질 배출량을 감소하는 효과를 얻을 수 있었다. 또한 회수된 오일의 총발열량은 40,900 J/g으로 확인되어 재생연료유로써의 자원 순환 효과를 기대할 수 있다. 대표적인 악취유발 사업장으로 알려져 있는 섬유산업내 텐터시설에서의 본 건식 전기집진기술을 이용하였을 경우 근본적인 민원 발생원을 제거함과 동시에 폐유에서의 부가가치 창출등의 효과를 기대함으로써 염색산단 악취 및 대기오염에 의한 사회적 문제를 해결할 수 있을 것이다.
        14.
        2014.07 KCI 등재 서비스 종료(열람 제한)
        The aim of this paper is to compare the characteristics of the T-P removal from synthesized municipal wastewater by electro-coagulation using cylindrical Al and Fe electrode as anode. For this purpose, a concentric circle type electrolysis reactor was used and the operating conditions for T-P removal from synthesized wastewater are as follows; potential 10 V, electrolyte 0.03% NaCl, initial T-P concentration 1.0 ~ 6.0 mg/L and flow rate 1.0 ~ 5.0 L/min. From the experimental results, T-P concentration of treated wastewater was decreased to less than 0.2 mg/L enough to discharge standard and Al electrode showed performance than Fe electrode for T-P removal by electro-coagulation. Optimal conditions for T-P removal to less than 0.15 mg/L which is 75% of discharge standard for large scale municipal wastewater plant (capacity higher than 500 m3/day) were obtained as follows; flow rate 2.503 L/min, and 2.337 L/min, HRT 1.059 min, 1.134 min, for Al and Fe electrode, respectively. Consumed mass of Al and Fe were of 3.76 times and 8.90 times respectively, were obtained to removed T-P at optimal conditions with potential 10 V, and 0.03% NaCl as electrolyte.