        검색결과 47

        1.
        2023.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Considering the non-linear behavior of structure and soil when evaluating a nuclear power plant's seismic safety under a beyond-design basis earthquake is essential. In order to obtain the nonlinear response of a nuclear power plant structure, a time-domain SSI analysis method that considers the nonlinearity of soil and structure and the nonlinear Soil-Structure Interaction (SSI) effect is necessary. The Boundary Reaction Method (BRM) is a time-domain SSI analysis method. The BRM can be applied effectively with a Perfectly Matched Layer (PML), which is an effective energy absorbing boundary condition. The BRM has a characteristic that the magnitude of the response in far-field soil increases as the boundary interface of the effective seismic load moves outward. In addition, the PML has poor absorption performance of low-frequency waves. For this reason, the accuracy of the low-frequency response may be degraded when analyzing the combination of the BRM and the PML. In this study, the accuracy of the analysis response was improved by adjusting the PML input parameters to improve this problem. The accuracy of the response was evaluated by using the analysis response using KIESSI-3D, a frequency domain SSI analysis program, as a reference solution. As a result of the analysis applying the optimal PML parameter, the average error rate of the acceleration response spectrum for 9 degrees of freedom of the structure was 3.40%, which was highly similar to the reference result. In addition, time-domain nonlinear SSI analysis was performed with the soil's nonlinearity to show this study's applicability. As a result of nonlinear SSI analysis, plastic deformation was concentrated in the soil around the foundation. The analysis results found that the analysis method combining BRM and PML can be effectively applied to the seismic response analysis of nuclear power plant structures.
        4,200원
        2.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        원자력발전소 기기 내진설계 및 지진해석은 비연계모델을 대상으로 수행된다. 그러나 이러한 비연계해석은 실제 구조물-기기 간 상호작용 등의 실제 현상을 모사할 수 없기 때문에 연계해석에 비하여 정확하지 못한 결과를 발생시키게 된다는 한계를 가진다. 이러 한 배경 아래 이 연구는 실제 원전 격납건물 구조물 및 관련 부계통을 대상으로 질량비와 고유진동수비를 고려하여 지진 연계해석과 비연계해석을 수행하고, 이를 바탕으로 부계통에서의 응답을 비교 분석하였다. 결과적으로 지진 연계해석 결과가 비연계해석 결과보 다 대다수 작은 값을 주는 것을 확인하였다. 이러한 결과는 기존 연구인 단순한 연계모델에 대한 해석 결과와 유사하지만, 부계통 응답 차이는 훨씬 더 두드러지게 나타나는 것을 확인하였다. 또한, 이는 지진파의 입력 주파수의 영향보다는 부계통의 설치위치에 영향을 받는 것으로 확인되었다. 마지막으로 비연계 및 연계 지진해석의 차이가 부계통의 질량비가 크고, 고유진동수가 거의 일치하는 영역 에서 발생하는 이유는 이 영역에서 주계통과 부계통 동적 상호작용이 크게 나타나기 때문인 것으로 보인다.
        4,000원
        3.
        2020.03 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        콘크리트 구조물 절단에 사용되고 있는 다이아몬드 와이어 쏘가 장착된 당김형 절단 장치의 단점을 개선하여 밀기형 절단장치를 개발하였다. 개발된 밀기형 절단장치에는 먼지 집진 커버가 부착되며 마찰열을 냉각하기 위한 건식이나 습식방법을 선택할 수 있다. 개발된 절단장치의 동작특성과 집진 먼지의 누설률 측정을 실험하였다. 시험결과 원활한 동작특성을 보였으며, 먼지의 누설률은 1.7%인 것으로 나타났다. 개발된 절단장비를 사용하여 생물학적 차폐 콘크리트 절단 시 작업자의 내부 피폭선량을 평가하였다. 보수적 평가를 위해 노심 중심부분을 절단하는 경우를 가정하였다. 비방사능이 99.5 Bq·g-1인 누설 먼지로 인해 반면마스크를 착용한 작업자의 예탁유효선량은 0.25 mSv로 평가되었다. 개발된 밀기형 절단장비 사용 시 미량의 먼지 누설률로 인해 작업자의 방사선 피폭이 저감되며, 사용의 편리성으로 세부 절단 계획을 수립할 수 있어 방사성 콘크 리트 폐기물 감량에도 기여할 수 있다. 따라서 원전의 방사화된 생물학적 차폐 콘크리트를 비롯하여 철근 콘크리트 구조물 해체 작업 시 절단 장비로서 사용될 수 있을 것이다.
        4,000원
        4.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 원자로 1400(APR 1400) 원자력 발전소(NPP)의 원자로 격납건물(RCB) 내진성능에 대해 상이한 수치모델과 지진 주파수 성분의 영향을 평가하는 것이다. 집중 질량 막대 모델(lumped-mass stick model, LMSM)과 3차원 유한요소모델(threedimensional finite element model, 3D FEM)의 두 가지 수치 모델이 시간이력해석을 수행하기 위해 개발되었다. LMSM은 기존의 집중 질량 보-요소를 사용하여 SAP2000으로 구성하였으며, 3D FEM은 각기둥 입체-요소를 사용하여 ANSYS로 작성되었다. 저주파수 및 고주파수 성분을 고려한 두 그룹의 지진파를 시간이력해석에 적용하였다. 저주파수 지진파의 응답스펙트럼을 NRC 1.60의 설계 스펙트럼과 일치되도록 조정하여 작성하였으며, 고주파수 지진파는 10Hz ~ 100Hz의 고주파수 범위를 갖도록 생성하였다. RCB의 지진응 답은 다양한 높이에서 층응답스펙트럼으로 검토하였다. 수치해석 결과, 저주파수 지진에 의한 구조물의 FRS 결과는 두 수치 모델에 서 매우 유사한 결과를 보였다. 하지만, 고주파수 지진에 의한 LMSM의 FRS 결과는 고차 고유 주파수 영역에서 3D FEM과 큰 차이를 보였으며, RCB의 낮은 높이에서 명확한 차이를 보였다. 3D FEM이 정확한 구조물의 응답을 나타내는 것으로 가정한다면, RCB의 LMSM은 고주파수 지진에 의한 FRS 결과의 고차 고유 주파수 영역에서 일정 수준의 불일치성을 내포하고 있다.
        4,000원
        5.
        2019.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A methodology to assess seismic fragility of a nuclear power plant (NPP) using a conditional mean spectrum is proposed as an alternative to using a uniform hazard response spectrum. Rather than the single-scenario conditional mean spectrum, which is the conventional conditional mean spectrum based on a single scenario, a multi-scenario conditional mean spectrum is proposed for the case in which no single scenario is dominant. The multi-scenario conditional mean spectrum is defined as the weighted average of different conditional mean spectra, each one of which corresponds to an individual scenario. The weighting factors for scenarios are obtained from a deaggregation of seismic hazards. As a validation example, a seismic fragility assessment of an NPP containment structure is performed using a uniform hazard response spectrum and different single-scenario conditional mean spectra and multi-scenario conditional mean spectra. In the example, the number of scenarios primarily influences the median capacity of the evaluated structure. Meanwhile, the control frequency, a key parameter of a conditional mean spectrum, plays an important role in reducing logarithmic standard deviation of the corresponding fragility curves and corresponding high confidence of low probability of failure (HCLPF) capacity.
        4,000원
        6.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to increase the seismic safety of nuclear power plant (NPP) structures, a technique to reduce the seismic load transmitted to the NPP structure by using a seismic isolation device such as a lead-rubber bearing has recently been actively researched. In seismic design of NPP structures, three directional (two horizontal and one vertical directions) artificial synthetic earthquakes (G0 group) corresponding to the standard design spectrum are generally used. In this study, seismic analysis was performed by using three directional artificial synthetic earthquakes (M0 group) corresponding to the maximum-minimum spectrum reflecting uncertainty of incident direction of earthquake load. The design basis earthquake (DBE) and the beyond design basis earthquakes (BDBEs are equal to 150%, 167%, and 200% DBE) of G0 and M0 earthquake groups were respectively generated for 30 sets and used for the seismic analysis. The purpose of this study is to compare seismic responses and seismic fragility curves of seismically isolated NPP structures subjected to DBE and BDBE. From the seismic fragility curves, the probability of failure of the seismic isolation system when the peak ground acceleration (PGA) is 0.5 g is about 5% for the M0 earthquake group and about 3% for the G0 earthquake group.
        4,200원
        7.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The seismically isolated nuclear power plants shall be designed for design basis earthquake (DBE) and considered to ensure safety against beyond design basis earthquake (BDBE). In order to limit the excessive displacement of the seismic isolation system of the seismically isolated structure, the moat is installed at a certain distance from the upper mat supporting the superstructure. This certain distance is called clearance to stop (CS) and is calculated from the 90th percentile displacement of seismic isolation system subjected to BDBE. For design purposes, the CS can be obtained simply by multiplying the median displacement of the seismic isolation system against DBE by scale factor with a value of 3. The DBE and BDBE used in this study were generated by using 30 sets of artificial earthquakes corresponding to the nuclear standard design spectrum. In addition, latin hyper cube sampling was applied to generate 30 sets of artificial earthquakes corresponding to maximum - minimum spectra. For the DBE, the median displacement and the 99th percentile displacement of the seismic isolation system were calculated. For the BDBE, the suitability of the scale factor was assessed after calculating the 90th percentile displacement of the seismic isolation system.
        4,000원
        8.
        2017.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to improve the seismic performance of structures, friction pendulum system (FPS) is the most commonly used seismic isolation device in addition to lead rubber bearing (LRB) in high seismicity area. In a nuclear power plant (NPP) with a large self weight, it is necessary to install a large number of seismic isolation devices, and the position of the center of rigidity varies depending on the arrangement of the seismic isolation devices. Due to the increase in the eccentricity, which is the difference between the center of gravity of the nuclear structure and the center of stiffness of the seismic isolators, an excessive seismic response may occur which could not be considered at the design stage. Three different types of eccentricity models (CASE 1, CASE 2, and CASE 3) were used for seismic response evaluation of seismically isolated NPP due to the increase of eccentricity (0%, 5%, 10%, 15%). The analytical model of the seismic isolation system was compared using the equivalent linear model and the bilinear model. From the results of the seismic response of the seismically isolated NPP with increasing eccentricity, it can be observed that the effect of eccentricity on the seismic response for the equivalent linear model is larger than that for the bilinear model.
        4,200원
        9.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to modeling seismic isolation system such as lead-rubber bearing (LRB), bilinear model is widely used by many researchers. In general, an actual force-displacement relationship for LRB has a smooth hysteretic shape. So, Bouc-Wen model with smooth hysteretic shape represents more accurately actual hysteretic shape than bilinear model. In this study, seismic responses for seismically isolated nuclear power plant (NPP) with LRB modelled by Bouc-Wen and bilinear models are compared with those of NPP without seismic isolation system. To evaluate effect of earthquake characteristics for seismic responses of NPP isolated by LRB, 5 different site class earthquakes distinguished by Geomatrix 3rd Letter Site Classification and artificially generated earthquakes corresponding to standard design spectrum by Reg. Guide 1.60 are used as input earthquakes. From the seismic response results of seismically isolated NPP, it can be observed that maximum displacements of seismic isolation modelled by Bouc-Wen model are larger than those by bilinear model. Seismic responses of NPP with LRB is significantly reduced than those without LRB. This reduction effect for seismic responses of NPP subjected to Site A (rock) earthquakes is larger than that to Site E (soft soil) earthquakes.
        4,000원
        10.
        2016.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study intends to evaluate the conservativeness of the fixed-base analysis as compared to the soil-structure interaction (SSI) analysis for the seismically isolated model of a nuclear power plant in Korea. To that goal, the boundary reaction method (BRM), combining frequency-domain and time-domain analyses in a twofold process, is adopted for the SSI analysis considering the nonlinearity of the seismic base isolation. The program KIESSI-3D is used for computing the reaction forces in the frequency domain and the program MIDAS/Civil is applied for the nonlinear time-domain analysis. The BRM numerical model is verified by comparing the results of the frequency-domain analysis and time-domain analysis for the soil-structure system with an equivalent linear base isolation model. Moreover, the displacement response of the base isolation and the horizontal response at the top of the structure obtained by the nonlinear SSI analysis using BRM are compared with those obtained by the fixed-base analysis. The comparison reveals that the fixed-base analysis provides conservative peak deformation for the base isolation but is not particularly conservative in term of the floor response spectrum of the superstructure.
        4,200원
        13.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 기초의 묻힘이 면진 원전구조물의 응답에 미치는 효과를 지표기초와 비교하여 평가하였다. 면진장치의 비선형 성을 고려한 비선형 SSI 해석은 진동수영역해석과 시간영역해석의 복합법인 경계반력법(BRM)을 이용하여 수행하였다. BRM 해석모델은 BRM을 이용한 등가선형 SSI 해석결과를 재래의 주파수영역 SSI 해석결과와 비교함으로 검증하였다. 마 지막으로 비선형 SSI해석에 의한 묻힌기초 모델의 면진장치의 변위 및 구조물 응답을 지표기초의 해석결과와 비교하였다. 비교결과, 면진장치의 변위응답은 묻힌기초효과를 고려할 경우 감소할 수 있음을 알 수 있었다.
        4,300원
        14.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Eradi Quake System (EQS) is a seismic isolation bearing system designed to minimize forces and displacements experienced by structures subjected to ground motion. The EQS dissipates seismic energy through friction of Poly Tetra Fluoro Ethylene (PTFE) disk pad. In general, a force-displacement relationship of EQS has post yield stiffness hardening during large inelastic displacement. In this study, seismic responses of seismically isolated nuclear power plant (NPP) subjected to design basis earthquake (DBE) and beyond design basis earthquakes (150% DBE and 167% DBE) are compared considering the post yield stiffness hardening effect of EQS. From the results, it can be observed that if the post-yield stiffness hardening effect of EQS is increased, the displacement response of EQS is reduced, and the acceleration and shear responses of containment structures of NPP is increased.
        4,200원
        15.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to improve seismic safety of nuclear power plant (NPP) structures in high seismicity area, seismic isolation system can be adapted. In this study, friction pendulum system (FPS) is used as the seismic isolation system. According to Coulomb‘s friction theory, friction coefficient is constant regardless of bearing pressure and sliding velocity. However, friction coefficient under actual situation can be changed according to bearing pressure, sliding velocity and temperature. Seismic responses of friction pendulum system with constant friction and various velocity-dependent friction are compared. The velocity-dependent friction coefficients of FPS are varied between lowand fast-velocity friction coefficients according to sliding velocity. From the results of seismic analysis of FPS with various cases of friction coefficient, it can be observed that the yield force of FPS becomes larger as the fast-velocity friction coefficient becomes larger. Also, the displacement response of FPS becomes smaller as the fast-velocity coefficient becomes larger.
        4,000원
        16.
        2015.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        ASCE 4 requires that a hard stop be built around the seismic isolation system in nuclear power plants. In order to maintain the function of the isolation system, this hard stop is required to have clearance-to-stop, which should be no less than the 90th-percentile displacements for 150% Design Basis Earthquake (DBE) shaking. Huang et al. calculated clearance-to-stop by using a Latin Hypercube Sampling technique, without considering the rocking behavior of the isolated structure. This paper investigates the effects on estimation of clearance-to-stop due to 1) rocking behavior of the isolated structure and 2) sampling technique for considering the uncertainties of isolation system. This paper explains the simplified analysis model to consider the rocking behavior of the isolated structure, and the input earthquakes recorded at Diablo Canyon in the western United States. In order to more accurately approximate the distribution tail of the horizontal displacement in the isolated structure, a modified Latin Hypercube Sampling technique is proposed, and then this technique was applied to consider the uncertainty of the isolation system. Through the use of this technique, it was found that rocking behavior has no significant effect on horizontal displacement (and thus clearance-to-stop) of the isolated structure, and the modified Latin Hypercube Sampling technique more accurately approximates the distribution tail of the horizontal displacement than the existing Latin Hypercube Sampling technique.
        4,000원
        17.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to increase seismic performance of nuclear power plant (NPP) in strong seismic zone, lead-rubber bearing (LRB) can be applied to seismic isolation system of NPP structures. Simple equivalent linear model as structural analysis model of LRB is more widely used in initial design process of LRB than a bilinear model. Seismic responses for seismically isolated NPP containment structures subjected to earthquakes categorized into 5 different soil-site classes are calculated by both of the equivalent linear- and bilinear- LRB models and compared each others. It can be observed that the maximum displacements of LRB and shear forces of containment in the case of the equivalent linear LRB model are larger than those in the case of bilinear LRB model. From the seismic fragility curves of NPP containment structures isolated by LRB, it can be observed that seismic fragility in the case of equivalent linear LRB model are about 5~30 % larger than those in the case of bilinear LRB model.
        4,200원
        18.
        2015.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        It is very important to assure the seismic performance of equipment as well as building structures in seismic design of nuclear power plant(NPP). Seismically isolated structures may be reviewed mainly on the horizontal seismic responses. Considering the equipment installed in the NPP, the vertical earthquake responses of the structure also should be reviewed. This study has investigated the vertical seismic demand of seismically isolated structure by lead rubber bearings(LRBs). For the numerical evaluation of seismic demand of the base isolated NPP, the Korean standard nuclear power plant (APR1400) is modeled as 4 different models, which are supported by LRBs to have 4 different horizontal target periods. Two real earthquake records and artificially generated input motions have been used as inputs for earthquake analyses. For the study, the vertical floor response spectra(FRS) were generated at the major points of the structure. As a results, the vertical seismic responses of horizontally isolated structure have largely increased due to flexibility of elastomeric isolator. The vertical stiffness of the bearings are more carefully considered in the seismic design of the base-isolated NPPs which have the various equipment inside.
        4,200원
        19.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated the influence of probabilistic variability in stiffness and nonlinearity of soil on response of nuclear power plant (NPP) structure subjected to seismic loads considering the soil-structure interaction (SSI). Both deterministic and probabilistic methods have been employed to evaluate the dynamic responses of the structure. For the deterministic method, SRPmin method given in USNRC SRP 3.7.2(2013) (envelope of responses using three shear modulus profiles of lower bound(GLB), best estimate(GBE) and upper bound(GUB)) and SRPmax method (envelope of responses by more than three ground profiles within range of GLB≤G≤GUB) have been considered. The probabilistic method uses the Latin Hypercube Sampling (LHS) that can capture probabilistic feature of soil stiffness defined by the median and the standard deviation. These analysis results indicated that 1) number of samples shall be larger than 60 to apply the probabilistic approach in SSI analysis and 2) in-structure response spectra using equivalent linear soil profiles considering the nonlinear behavior of soil medium can be larger than those based on low-strain soil profiles.
        4,300원
        20.
        2015.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents a detailed procedure for a nonlinear soil-structure interaction of a seismically isolated NPP(Nuclear Power Plant) structure using the boundary reaction method (BRM). The BRM offers a two-step method as follows: (1) the calculation of boundary reaction forces in the frequency domain on an interface of linear and nonlinear regions, (2) solving the wave radiation problem subjected to the boundary reaction forces in the time domain. For the purpose of calculating the boundary reaction forces at the base of the isolator, the KIESSI-3D program is employed in this study to solve soil-foundation interaction problem subjected to vertically incident seismic waves. Wave radiation analysis is also employed, in which the nonlinear structure and the linear soil region are modeled by finite elements and energy absorbing elements on the outer model boundary using a general purpose nonlinear FE program. In this study, the MIDAS/Civil program is employed for modeling the wave radiation problem. In order to absorb the outgoing elastic waves to the unbounded soil region, spring and viscous-damper elements are used at the outer FE boundary. The BRM technique utilizing KIESSI-3D and MIDAS/Civil programs is verified using a linear soil-structure analysis problem. Finally the method is applied to nonlinear seismic analysis of a base-isolated NPP structure. The results show that BRM can effectively be applied to nonlinear soil-structure interaction problems.
        4,000원