검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 5

        1.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As water resources are limited and legal regulations are strengthened, there is a growing need to reuse residuals in WTP(Water Treatment Plant). In this study, membrane filtration system was constructed and its operation method was studied for water quality stabilization and reuse of WTP residuals. The operation parameters were stable for 1 year and 6 months. Membrane fouling was identified as particulate pollution (activated carbon) and inorganic pollution (manganese). The membrane system was operated steadily with raw water of high concentration SS(Suspended solid) containing activated carbon because membrane fouling was reduced by the effect of End-Free type. In the case of inorganic contamination, dissolved manganese eluted by chemicals and acted as a membrane fouling source, and the operating conditions for minimizing membrane fouling were confirmed by newly developing application methods and types of cleaning chemicals. Based on the results, design parameters for reducing manganese membrane fouling were derived.
        4,300원
        2.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Membrane backwashing waste shows seasonally different characteristics and it has bad settleability differently from general backwashing waste in water treatment plant. When chemicals was injected to membrane backwashing waste, the settleability was better than chemicals was not injected. However, when settled lower sludge was not discharged, flowing sludge continuously was concentrated over a certain surface and floatation penomena occurred according to flowing velocity. When the lower sludge was discharged continuously in the thickener to prevent floatation penomena of turbidity materials, the depth of sludge surface was the least and the settleability increased.
        4,200원
        3.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Various treatment system for residuals have applied to save water resources, but most of them were not be satisfied with legal standard consistently. In this study, submerged membrane treatment system was operated to treat water treatment plant residuals and operation parameters was evaluated. Result of this experiment, high concentration organic matters contributed to high increase Transmembrane pressure(TMP) of membrane system(from 0.05 bar to 0.35 bar). And backwash process was effective to stabilize membrane system operation. After Cleaning-In-Place(CIP), permeability was recovered about 100 % from first operation condition. Inorganic matters (Fe, Mn, Al, Ca, Mg) were not effective membrane filtration performance. The quality of residual treatment was satisfied with drinking water quality standard and a treated water from that system was suitable for water reuse.
        4,500원
        4.
        2006.02 구독 인증기관 무료, 개인회원 유료
        Analysis of design parameters of residual treatment process at eight model water treatment plants, which were located in the four major watersheds, showed that there were large differences between those design parameters and the actual conditions. In this background, a new procedure was proposed and applied to the Chungju water treatment plant as an example of the optimum design of residual treatment process based on the characteristics of raw water. In this design example, a filter backwash recycle system consisting of a surging tank and sedimentation basin was newly proposed for more safe recycle of spent backwash water. It is expected that the design procedure proposed in this study would be estimated as a meaningful attempt to develope new design procedure for the domestic water industry.
        5,400원