Many older reinforced concrete (RC) buildings were constructed and designed with only gravity loads in mind. Columns in those buildings have insufficient reinforcement details that do not satisfy the requirements specified in current seismic design standards. This study aims to develop drift-based fragility functions for lightly RC columns. For this purpose, a database of 193 lightly RC columns was constructed to determine central and dispersion values of drift ratios for individual damage states. Additionally, to develop more accurate fragility functions of the columns, the failure mode of RC columns was incorporated into fragility functions. The classification procedure for column failure mode is proposed in this study. Fragility functions for older RC columns are constructed according to four different damage states. The main variables of the fragility functions proposed in this study are column properties and failure mode.
Steel brace strengthening is the most popular seismic rehabilitation method for school buildings. This is because the design can be conducted by using relatively easy nonlinear pushover analysis and standard modeling in codes. An issue with steel brace strengthening is that the reinforced building should behave elastically to satisfy performance objectives. For this, the size of steel braces should be highly increased, which results in excessive strengthening cost by force concentration on existing members and foundations due to the considerable stiffness and strength of the steel braces. The main reason may be the brittle failure mode of columns, so this study investigated the relationship between the efficiency of steel brace strengthening and column failure modes. The result showed that the efficiency is highly dependent on the shear capacity ratio of columns and structural analysis methods. School buildings reinforced by steel braces do not need to behave elastically when the shear capacity ratio is low, and pushover analysis is used, which means reducing steel material is possible.
As earthquakes have increased in Korea recently, people are paying attention to the seismic performance of buildings built in the past. Many school buildings in Korea were built based on standard drawings before the seismic design was applied. However, since school buildings are often designated as emergency evacuation facilities in case of disasters such as earthquakes, seismic evaluation and retrofit must be done quickly. This study investigated the failure modes among structural components (beams, columns, and joints), focusing on 1980s standard drawings for school buildings. The effects of column axial force, partial masonry infills, and different material strengths for concrete and rebar were considered for detailed evaluation. As a result, most of the joints were found to be the weakest among structural components. Column axial forces tended to make the joints more vulnerable, and partial masonry infills increased the possibility of joint failure and shear failure in columns.
As earthquakes continue to occur in Korea in recent years, seismic evaluation and retrofit of existing school buildings have been carried out. Many domestic school buildings were built using or referring to standard drawings. Therefore, if the overall structural characteristics of a school building can be known first based on standard drawings, it can be provided as valuable data for detailed seismic evaluation. For this reason, this study investigated the weak structural components and failure modes by comparing the strength of beams, columns, and joints constituting standard school buildings constructed in the 1980s. The evaluation was performed for different types of standard drawings and different material strengths. The results showed that the joint was mainly the weakest due to the eccentricity, and the failure modes were partially changed depending on the material strength.
Most commercial buildings among existing RC buildings in Korea have a multi-story wall-frame structure where RC shear wall is commonly used as its core at stairways or elevators. The members of the existing middle and low-rise wall-frame buildings are likely arranged in ordinary details considering building occupancy, and the importance and difficulty of member design. This is because there are few limitations, considerations, and financial burdens on the code for designing members with ordinary details. Compared with the intermediate or unique details, the ductility and overstrength are insufficient. Furthermore, the behavior of the member can be shear-dominated. Since shear failure in vertical members can cause a collapse of the entire structure, nonlinear characteristics such as shear strength and stiffness deterioration should be adequately reflected in the analysis model. With this background, an 8-story RC wall-frame building was designed as a building frame system with ordinary shear walls, and the effect of reflecting the shear failure mode of columns and walls on the collapse mechanism was investigated. As a result, the shear failure mode effect on the collapse mechanism was evident in walls, not columns. Consequently, it is recommended that the shear behavior characteristics of walls are explicitly considered in the analysis of wall-frame buildings with ordinary details.
This study aims at investigating the fracture characteristic according to the shape of the double cantilever beam specimen for mode II with ultra-high strength steel and Mg alloy steel. As the analysis, all three models had the left-hand holes that were constrained by the cylindrical support and the right-hand holes were enforced by the constraint condition of 6mm/min. This study result showed that the shorter the load block of the double envelope test specimen, the higher the safety. The results of this study are thought to be useful for examining the fracture characteristics of specimen for mode II with ultra high strength steel and Mg alloy steel.
Recently, for efficiency increase of the wind turbine tower, turbine has been enlarged and installation location has been transferring to offshore. The importance of the support structure is emphasized when a wind turbine tower is installed on offshore. The support structure is influenced not only by the system operating loads but also by various marine condition loads. Accurate and safe design is essential because the connection between the support structure and the wind tower can be relatively fragile. In particular, the type of foundation pile and sleeve grout connection were adapted from DNV, API, and ISO that are typically used for wind towers, and they have been continuously studied by many researchers. However, the experimental results by researchers are different from the design equations, and it needs to modify the formula according to connection properties and material. Therefore, this study investigates the design equation presented in existing design criteria and the results of research conducted by existing researchers, and analyzes ultimate strength and failure modes.
Behavior of RC(Reinforced-concrete) beam-column connections has been subjected to the earthquake loading has been determined by shear and attachment mechanism. However, since the shear and attachment are very fragile for cycle loadings. Through occurring plastic hinges at the beam, the column and the connection should remain elastic condition and the beam should dissipate the energy from the earthquake. This study was investigate on the seismic performance of 6 RC beam - column connections built with the high strength reinforcements (700MPa) based on design and detailing requirements in the ACI 318-05 Provision and KCI-07 appendix Ⅱ. This is aimed to evaluate the effect of the high-strength reinforcements as used the beam-column connection members. The main comparisons were the seismic performance of the connections affect the seismic performance in terms of strength, stiffness and ductility, joint shear stress-strain. A total of 6 beam-column specimens were built with a 1/2 scale and subjected to the cyclic loadings. Main design considerations were the area of the longitudinal reinforcements of the beam and details of the beam-column joint designed based on the seismic code. Cyclic test results are given and recommendations for the usage of high strength reinforcements for the seismic design is provided.
In this study, carbon/epoxy composite DCB(double cantilever beam) specimens based on K-means clustering and wavelet transform analyses are presented. For the fracture Mode I, the fiber orientation θ = [0 ]24 and θ = [±45]12 both shown up stable crack growth in DCB testing. For the fiber orientation θ = [0 ]24 , the continuous type AE signal showed at central frequency 130~270kHz, which means that matrix micro cracking was occurred. The Burst type AE signal was occurred at central frequency 200~300kHz due to fiber bridging and fiber breaking. Other burst type AE signals were occurred at central frequency 130~180kHz with very high amplitude due to fiber bridging. For the fiber orientation θ = [±45]12 , the burst type signal showed at central frequency 220~300kHz, which means that fiber breaking was occurred. Mixed type of burst and continuous signals were captured at central frequency 250~480kHz due to fiber friction.
대공간구조에서 접합부의 신뢰도는 매우 중요하다. 접합부에 사용되는 고력볼트의 나사부 유효단면적은 축부단면적보다 작고 볼트 축부에 락핀용 구멍이 있기 때문에 볼트 나사부 또는 락핀용 구멍에 응력집중 현상이 발생하여 취성 파단이 발생할 우려가 높다. 특히 접합부는 직렬형 구조로 이루어져 있다. 따라서 접합부에서의 극한상황시 파괴유형은 필히 취성파괴를 피해야 하며 연성파손으로 유도해야 한다. 따라서 본 연구에서는 볼 조인트 접합부의 소성변형능력을 향상시키고 현장에서 발생할 수 있는 시공오차의 흡수가 가능하도록, 볼트의 나사부나 핀부의 취성파단 없이 소성변형능력 향상을 목표로 하였다. 에너지흡수형 볼트를 사용함으로써 소성변형능력이 향상된 스페이스 프레임의 접합상세를 제안하였다.
본 연구는 복합재료 교량시스템의 규준 정립을 위한 연구로서 실제 설계 시공되어진 복합재료 교량의 정밀해석수행과 이를 통한 복합재료 교량의 파괴거동 및 설계기준 등을 조사하는데 그 목적이 있다. 본 연구의 효율적인 연구를 위하여 실제 미국 NEW YORK주 내에 설계 시공되어있는 Noncomposite-FRP 복합재료 교량을 대상으로 해석적 연구를 수행하였으며 본 연구에서 사용된 해석적 모델을 토대로 실제 미국에서 기 수행되어진 교량 거동에 관한 해석 및 실험하중 평가와 그 결과를 비교하였다. 특히 국내 복합재료 교량의 해석적 설계기준 평가를 위하여 보다 실질적이고 정확한 파괴모드의 조사 및 분석이 요구되어지므로 본 연구에서는 이를 위하여 기존의 해석적 연구에서 가벼운 중량으로 인하여 무시되었던 자중의 영향과 각 적층 layer에 설계된 ply orientation을 고려하여 해석하였다. 그 결과 자중을 고려한 복합재료 패널들의 경우, 제작 결함에 따른 이음부 파괴가 없을 경우 교량 상부 구조 중 횡축 보에서의 국부 좌굴 파괴가 교량의 파괴를 지배할 것으로 본 연구결과에서 예측되었다. 이는 복합재료 교량 제작 시 복합재료 상판 패널과 보의 이음부가 Noncomposite로 제작되는 경우 실제 제작되어진 복합재료 상판의 고 강성에 의하여 재하 하중에 의한 하부 강재 거더 좌굴이 선행되는 것으로 판단된다.
고강도 재료(고강도 콘크리트, 고강도 철근)가 사용된 철근콘크리트 부재의 전단파괴모드는 보통강도 재료를 사용한 부재의 전단파괴모드와 상이한 결과를 나타낼 수 있다. 고강도 재료가 사용될 경우에 구조설계기준식에서 요구하는 전단보강철근이 먼저 항복한 후에 콘크리트가 압축파괴하는 것과는 다르게, 철근이 항복하기 이전에 콘크리트가 압축파괴할 수 있다. 이 논문에서는 고강도 재료가 사용된 철근콘크리트 부재의 최대철근비를 균형파괴시의 재료의 응력 및 변형률 상태를 이용하여 계산하였다. 제안식에서 최대철근비는 콘크리트의 압축강도와 전단보강철근의 상호관계에 의하여 변화하였다. 제안식은 97개의 철근콘크리트 부재에 대한 실험결과와 비교되었다. 실험결과 및 계산결과는 철근콘크리트 부재의 파괴모드가 전단보강철근의 양과 콘크리트의 압축강도와 밀접한 관계가 있음을 나타내었다.
본 논문에서는 내구성과 수명을 획기적으로 향상시키기 위해 제3세대 건설재료인 섬유강화 플라스틱(FRP) 소재로 제작된 사각형 중공 교량 바닥판의 파괴모드를 실험과 해석을 통해 분석하였다. 재하시험 결과 바닥판의 강축방향의 거동은 파괴 직전까지도 거의 선형탄성적으로 거동한 반면, 약축방향의 거동은 재하초기부터 작은 하중하에서도 큰 비선형성을 보였다. 이 약축방향 비선형성의 원인은 웨브와 플랜지 연결부의 불완전한 일체거동으로 인한 소성거동 때문인 것으로 판단된다. 웨브와 플랜지의 연결부에 소성힌지를 도입한 간단한 구조모델을 이용하여 이를 확인하였다. 접착부의 박리 파괴 가능성도 검토하였으나 이는 대상 중공바닥판의 약축방향 파괴에 직접적으로 관여하는 것은 아닌 것으로 판단된다 약축방향의 구조거동을 개선시키기 위한 방안으로 내부를 폼으로 충전하는 방법을 제시하였으며 그 가능성을 구조해석을 통해 확인하였다.
하이브리드 복합재료(Hybrid composite)의 모드 I 층간파괴인성치에 영영향 주는 인자 중 적층순서, 하중점변위율, 초기크랙길이를 변화 시켰을 때의 실험 결과는 다음과 같다. (1) CF/CF, CF/GF, GF/GF로 적층하였을 경우 층간파괴인성치값은 서로 같은 계면을 성형한 것보다 서로 다른 계면을 적층한 CF/GF 의 경우가 강도면에서 가장 높게 나타나는 것을 알 수 있다. (2) 하중점변위율을 0.2, 2, 20mm/min로 변화하였을 때, 미세한 변동은 있었으나, 허중점변위율의 영향은 거의 받지 않는 것을 알 수 있었다. (3) 초기크랙을 25, 30, 35, 40, 50mm로 변화시켰을 때 초기크랙길이의 영향은 일정하지 않았다. CF/CF인 경우는 초기크랙이 짧은 경우, CF/GF, GF/GF인 경우는 초기크랙이 긴 경우에 높은 값을 나타냈다. 이것은 GF 섬유가 직조형태의 프리프레그로 되어 있어 크랙의 진전에 따라 섬유부스러기 등의 생성에 따른 영향이라고 생각된다. (4) 적층순서에 따라 파면의 섬유 분포 형태가 달랐으며, CF/GF인 경우가 섬유의 파손형태가 가장 복잡하게 나타났으며, 이것이 높은 층간파괴인성치를 나타내는 원인이라고 판단된다.
PSC 보의 비파괴 손상검색을 위한 고유진동수 이용 손상추정법과 모드형상 이용 손상추정법을 제시하였다. 먼저, 고유진동수의 변화를 사용하여 손상의 위치를 예측하는 알고리즘과 고유진동수 1차 섭동 이론에 근거하여 균열크기를 예측하는 알고리즘을 요약하였다 다음으로, 모드형상의 변화로부터 모드민감도의 변화를 감지하고 이를 통해 손상의 위치와 크기를 추정하는 손상지수 알고리즘을 요약하였다. PSC 보의 유한요소모델을 사용하는 수치실험을 통해 고유 진동수 이용 손상추정법과 모드형상 이용 손상추정 법의 정확성을 검증하였다. 분석결과 두 방법 모두 실험 대상 구조에 도입된 균열의 위치를 정확하게 예측하였으며 균열의 크기를 비교적 근사하게 예측하였다.
캘리포니아의 강구조 모멘트프레임은 1994년 노스리지 지진시 6.8의 규모와 진앙지에서 근접한 지리적인 악조건에도 불구하고 붕괴나 인명피해 없이 잘 견뎌냈다. 그러나 이후 시행된 조사에서 경제적으로 지진시 안전하다고 믿어져 널리 쓰인 welded flange-bolted web(WFBW) 강접합부(moment connection)의 기둥과 용접의 경계면에서 취성 파괴가 다수 발견되었다. 이논문은 선형파괴역학과 노스리지진이후의 WFBW 강접합부 실험을 이용하여 WFBW 강접합부와 노스리지지진이후 기존 강접합부의 대안으로 추천되고 있는 reduced beam section (RBS) 강접합부의 취성 파괴강도를 결정하는 수치적인 방법을 제안하고 이를 이용하여 이들 강접합부의 취성 파괴모드를 추정하였다.
본 연구는 가스압소결 질화규소의 혼합모드에 있어서 파괴거동을 실온 및 1000˚C에서 조사하였다. 실험은 누프압흔을 도입한 시험편을 사용하여 소둔처리에 의해 잔류응력을 제거하고, 4점굽힘법을 이용하였다. 실험결과, 종래 제창되고 있는 파괴기준과 일치하지 않고, 그래서 새롭게 4차관수의 근사식을 제안하였다.
강도가 각각 다른 세 종류의 프리프레그를 사용하여 일방향 CFRP를 적층하였으며, 모드 I과 모드 II 실험을 통하여 층간 파괴인성치를 고찰하였고, 또한 적층 섬유방향을 변화시킨 사교적층판의 그것도 함께 고찰하였으며, 이를 요약하면 다음과 같다. 1) 임계에너지 방출률 G 하(IC)의 값을 컴플라이언스 법, 수정 컴플라이언스 법, 그리고 보이론에 의해 계산하여 비교 검토한 결과 본 연구에서 사용한 수정식에 의한 값들이 거의 일치하였다. 2) G 하(IC) 값은 대체로 프리프레그의 C, B, A재의 순으로 높게 나타났으며, G 하(II C)의 값을 세가지 식에 의해 계산하여 비교 검토한 결과 거의 일치하였다. 3) 사교적층판의 경우 G 하(IC) 값은 [0/90] 하(6s), [0/45] 하(6s), [0/45/90] 하(6s)의 순으로 높게 나타났으며, G 하(II C)는 [0/90] 하(6s), [0/45/90] 하(6s), [0/45] 하(6s)의 순으로 높게 나타났다. 4) 사교적층판과 일방향의 임계에너지 방출률을 비교하였을 때, 모드 I의 경우 일방향의 결과가 다소 높았으며, 모드 II의 경우는 [0/45] 하(6s)의 결과는 거의 일치함을 알 수 있었다.
혼성제 케이슨에서 발생 가능한 활동, 전도 그리고 편심 경사하중에 의한 마운드 지지력에 대한 안정성을 다중 파괴모드 개념으로 해석하였다. 먼저 결정론적 해석에서는 활동 및 전도 그리고 마운드 지지력에 대한 한계 상태방정식을 이용하여 최소 안전율을 만족하는 혼성제 케이슨의 최소 단면을 산정할 수 있는 식을 유도하였다. 입사조건 및 마루높이 그리고 설치수심에 따른 결정론적 해석 결과에 의하면 활동 파괴모드와 마운드 지지력 파괴모드 간 상충이 발생되었다. 따라서 혼성제 케이슨의 설계단면을 결정론적으로 산정하는 경우에도 활동뿐만 아니라 전도와 마운드 지지력에 대한 다중 파괴모드를 동시에 고려하여야 한다. 한편 확률론적 해석에서는 활동에 의하여 결정된 단면에 대하여 다중 파괴모드에 대한 시스템 신뢰성 해석을 수행하였다. 혼성제 케이슨의 다중 파괴모드에 의한 제체의 시스템 파괴확률이 입사조건에 따라 매우 다르게 거동하는 것을 알 수 있었다. 또한 마루높이와 설치수심이 증가하여도 제체의 시스템 파괴확률이 증가하는 경향이 나타났다. 특히 시스템 신뢰성 해석의 일차 해석모형과 이차 해석모형의 결과들은 본 연구에서 수행된 조건들에서는 일치되는 거동 특성을 나타냈다. 그러나 파괴모드 사이의 상관성을 올바로 고려할 수 있는 이차 해석모형의 결과가 더 높은 정도를 갖는다. 다만 파괴모드 사이에 파괴확률이 상대적으로 크게 차이나는 경우에는 일차 해석모형도 간편하게 사용할 수 있다.