검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 41

        1.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The function of coolant in machining is to reduce the frictional force in the contact area in between the tool and the material, and to increase the precision by cooling the work-piece and the tool, to make the machining surface uniform, and to extend the tool life. However, cutting oil is harmful to the human body because it uses chlorine-based extreme pressure additives to cause environmental pollutants. In this study, the effect of cutting temperature and surface roughness of titanium alloy for medical purpose (Ti-6Al-7Nb) in eco-friendly ADL slot shape machining was investigated using the response surface analysis method. As the design of the experiment, three levels of cutting speed, feed rate, and depth of cut were designed and the experiment was conducted using the central composite planning method. The regression expressions of cutting temperature and surface roughness were respectively obtained as quadratic functions to obtain the minimum value and optimal cutting conditions. The values from this formula and the experimental values were compared. As a result, this study makes and establishes the basis to prevent environmental pollution caused by the use of coolant and to replace it with ADL (Aerosol Dry Lubricant) machining that uses a very small amount of vegetable oil with high pressure.
        4,000원
        3.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzes the internal temperature characteristics of heater module using a numerical method when the constant heat flux and heat flux time are applied to the surface heating element. The horizontal and vertical dimensions of heater module are 100mm, and the height is 5mm. The heat flux is 10,000W/m2, 15,000W/m2, and 20,000W/m2, and heat flux time is 5 seconds, 10 seconds, 15 seconds, 20 seconds, 30 seconds and 50 seconds, respectively. When the heat flux time was 50 seconds, the temperature of the surface heating element rose to 120.5°C, while the skin epidermis temperature rose 1.7°C. As a result, the surface temperature of the surface heating element increased greatly in the horizontal direction, while it increased low in the depth direction. This is because the heat conduction of the surface heating element is transmitted in the X-Y plane direction, and the thermal conductivity of the pet(polyethylene terephthalate) film and insulation sheet under the surface heating element is very low. when the heat flux at the surface heating element is 20,000W/m2, the skin's epidermal temperature rises up to 0.82℃ compared to 10,000W/m2 and 15,000W/m2.
        4,000원
        4.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A magnetic abrasive finishing process was proposed for improving the surface accuracy of microscale -diameter STS 304 bar used in many applications such as, medical, aerospace, and nuclear industries. Most of the previous research has already explored the conventional finishing technique to improve the accuracy of material in terms of the surface roughness. However, their results are still not good enough for the requirement in the today’s engineering industry. Especially, when the workpiece is a material of microscale-diameter, use of such conventional processes becomes impossible because they entail the application of high pressures that may damage the surface to be finished. Moreover, less control is available over these conventional finishing processes. In this study, an ultra-high-precision magnetic abrasive finishing process was applied to the precision machining of microscale-diameter STS 304 bar and the experimental work are performed with many critical parameters such as, different workpiece revolution speeds, abrasive grain sizes, different finishing temperatures, and pole vibrations. The results showed that in The initial surface roughness of 0.20 μm (Ra) was decreased to 0.025 μm with 0.5 μm of abrasive grain size and pole vibration 12Hz at 40,000 rpm.
        4,000원
        5.
        2019.11 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        In this study, we investigate the relationship between the peeling behavior of the backsheet of a photovoltaic(PV) module and its surface temperature in order facilitate removal of the backsheet from the PV module. At low temperatures, the backsheet does not peel off whereas, at high temperatures, part of the backsheet remains on the surface of the PV module after the peeling process. The backsheet material remaining on the surface of the PV module is confirmed by X-ray diffraction(XRD) analysis to be poly-ethylene(PE). Differential scanning calorimetry(DSC) is also performed to investigate the interfacial characteristics of the layers of the PV module. In particular, DSC provides the melting temperature(Tm) of laminated ethylene vinyl acetate(EVA) and of the backsheet on the PV module. It is found that the backsheet does not peel off below the Tm of ethylene of EVA, while the PE layer of the backsheet remains on the surface of the PV module above the Tm of the PE. Thus, the backsheet is best removed at a temperature between the Tm of ethylene and that of PE layer.
        4,000원
        6.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 피부표면온도가 유효물질 경피 흡수와 피부 상태변화에 미치는 영향을 실험하였다. 열에 강한 나이아신아마이드 10% 에멀젼을 인공피부에 도포하여 경피 흡수 시험을 진행하였고 동일한 에멀젼으로 피부임상시험을 시행하여 온열효과를 확인하였다. 그 결과 피부표면 온도 42℃에서 정상 피부 온 도보다 도포 10분 경과 후 2배, 15분 경과 후 3배의 경피 흡수 효과를 보였다. 피부임상평가에서는 임상대상자 모두 특이한 이상반응을 보이지 않았으며 수분, 유분 항목에서 통계적으로 유의한 효과를 나타냈다. 이상의 결과로 온열은 유효물질 경피 흡수 촉진과 피부상태 개선에 긍정적인 영향을 미치는 것을 확인하였고 이는 온열을 이용한 다양한 뷰티디바이스 개발에 기초자료가 될 것으로 판단된다.
        4,000원
        8.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the characteristics of muscle relaxation were analyzed by the experimental and numerical method. A skin tissue was produced by imitational biological tissue using the agar powder, saline solution and sugar. The tissue was exposed to three types of wavelength-blue visible radiation(410 nm), red visible radiation(635 nm), and infrared ray(830 nm). The temperature results along the depth of tissue were measured according to the variation of light wavelength and irradiation time. The temperature change of the tissue shown up similar pattern regardless of the light wavelength kinds. The wavelength of infrared ray penetrated strongly into tissue between 3.2 mm and 11.4 mm. Also, the temperature change with the irradiation time was small, and the temperature value of the infrared ray was the largest. As a result, the muscle relaxation will occur mainly at the infrared wavelength.
        4,000원
        9.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적: 백내장 환자를 대상으로 수술 전과 후의 안구표면의 온도변화 양상을 열화상카메라의 서모그래피를 이용하여 연구 하고자 하였다. 방법: 본 연구는 백내장 수술을 받은 환자 50-79세까지 75명 75안의 환자 군을 대상으로 하였다. 과거에 굴절교정수술, 각막관련 수술을 받은 자와 콘택트렌즈를 사용하는 자, 눈물관 이상자, 전신질환 치료 약물을 복용하는 자 등 눈물분비와 눈물막에 영향을 줄 수 있는 자는 연구 대상자에서 제외하였고 눈물막파괴시간 검사(Tear Break Up Time, BUT), 쉬르머 검사(Schirmer’s Test), 맥모니테스트(Mcmonnies questionnaire)를 시행한 후 열화상카메라(Cox CX series, Answer., Korea)를 이용하여 안구표면의 온도변화를 실시간으로 측정하였다. 결과: 전체 대상자의 술 전 안구표면 온도는 35.20±0.54 ℃이었고 술 후에는 35.30±0.53 ℃로 표면온도가 상승하였으나 유의한 차이를 보이지 않았다. 안구표면 온도변화는 술전에서 -0.12±0.08 △(℃/sec)에서 술 후 -0.18±0.07 △(℃/sec)로 통계학적으로 유의한 결과를 나타냈다. 연령 별 비교에서는, 50 대군은 백내장 술 전 대상자의 안구표면 온도변화가 -0.14±0.09 △(℃/sec)에서 -0.19±0.05 △(℃/sec)으로 나타났고 60 대군에서는 -0.12±0.08 △(℃/sec)에서 -0.15±0.07 △(℃/sec)으로 나타났으며 70 대군에서는 술 전 대상자의 안구표면 온도변화는 -0.12±0.08 △(℃/sec)에서 -0.18±0.07 △(℃/sec)으로 전 연령에서 모두 유의한 안구표면 온도변화를 보였다. 결론: 백내장 술 후에는 안구건조증 평가지표가 모두 감소하였고 안구표면 온도변화가 유의함을 보였다. 안구표면의 서모그래피 기술은 비침습적으로 안구건조증을 평가하는데 용이하였고 객관적으로 수치화할 수 있는 장점이 있어 다양한 안구건조증 연구에 활용 될 것으로 기대된다.
        4,000원
        10.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to evaluate thermal performance using the ASTR method. Its findings are as follows: 1) The measured U-Values of 49A type and 59A type walls were almost the same as the theoretically calculated values. 2) One notable phenomenon for both walls was that the interior surface temperatures of the channels attached to corners were up to 10.4% lower than that of the cross of the wall, even though they consisted of the same materials. This is due to the surface temperature drop caused by the thermal bridge. 3) The surface temperatures of the thermal bridge were converted into U-Values. The U-Value of the top left corner on the 59A type house was 1.044W/m²K, and of the bottom right corner on the 49A type house was 0.959W/m²K. Therefore, the thermal performance of the thermal bridge area was decreased after construction. 4) Differences were found in the results of comparing heat transfer analysis simulation data and measured data. A maximum difference of 12.4% occurred in the top left corner on 59A type, and of 7.6% occurred in the bottom right corner on 49A type. 5) The results of a heat transfer analysis simulation showed that the temperature of both 49A type and 59A type top right corner were the lowest, but in-situ measurement results were the lowest in the bottom right corner on 49A type and in the top left corner on 59A type. These results are considered to be due to the occurrence of thermal bridges and a deterioration in the construction quality.
        4,000원
        13.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we designed the 3-dimensional tire mold according to the A automobile company’s tire model, and analysed the distribution of temperature of mold using the numerical method when the heat flux and heat transfer time at the surface of tire mold were changed. A analysis region of mold was the 1/16 of entire mold, and the grid number was about more than 880 thousand. In order to analyze the temperature change of mold, the thinnest part of the mold was chosen as the research object, and then the temperature of 6 points on the vertical downward direction of the thinnest part was analyzed with the time change. While the numerical condition was that heat flux was 321,200 W/m2, 440,000 W/m2 and 880,000 W/m2, and measuring time was 0.1 second, 0.2 second, 0.5 second and 1 second, respectively. As a result, the temperature difference between the surface temperature and the lowest temperature of mold was 7.3℃ when the heat transfer time was 0.1 second. Also, the minimum temperature difference was almost 0.11℃ when the heat transfer increased to 1 second. It can be explained that the main material of tire mold was aluminum and its thermal conductivity was high (k=140 W/m·K). In addition, when the heat transfer time was more than 1 second, the heat flux of mold surface will be transmitted at the inside of the thinnest part, and the heat transfer will be a marked difference according to the shape of the thinnest part.
        4,000원
        14.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 위성관측 표면온도 및 해당 온도경향의 불확실성을 조사하기 위하여 북반구(30-90˚N) 해양 지역에서 2003-2014년 4월 16-24일 기간에 세 종류의 위성관측 자료(MODIS IST, AIRS/AMSU SST, AIRS only SST)를 상호 비교하였다. AIRS/AMSU 표면온도값에 비하여 MODIS는 해빙과 해수의 경계지역에서 계통적으로 최대 1.6 K 높은 반면에, 해빙 지역에서는 2 K 낮았다. 이러한 주요 원인은 표면온도 산출알고리즘의 해표 정보(e.g., 해빙 탐지)를 위하여 MODIS는 적외 채널만을 사용하는 반면에, AIRS/AMSU는 마이크로파 및 적외 채널을 함께 사용하는 데에 있다. 미국 항공우주국(NASA's Goddard Space Flight Center; NASA/GSFC)은 AMSU-A의 노후화를 대비하기 위하여 AIRS/AMSU 알고리즘을 일부 수정하여 AIRS only 알고리즘을 개발하였다. AIRS/AMSU와 AIRS only 표면온도 사이에 평균 제곱근 오차(RMSE)값은 30-90˚N 해양 지역에서 0.55 K이며, 편차(bias)는 0.13 K이었으며, 해빙/해수 경계 지역에서는 이들 차이가 더 크게 나타났다. 해빙 경계지역에서 AIRS/AMSU와 AIRS only 간의 차이가 다른 지역에 비하여 큰 이유는 AIRS only 알고리즘이 AMSU 마이크로파 자료 대신에 GCM (NOAA Global Forecast System) 온도 산출물을 사용하는 데에 있다. 세 종류의 위성관측 표면온도 자료는 70-80˚N 위도대에서 유의적인 온도증가(0.23-0.28Kyr-1)를 보였다. 위성관측 표면온도들 간에 계통적인 불일치는 같은 방향(온도증가 또는 온도감소)으로 해당 온도경향 값들 간의 차이에 영향을 줄 수 있다.
        5,400원
        15.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        총체 사료용 벼의 초기 신장성과 입모 특성을 알아보기 위하여 수원 소재 국립식량과학원 시험포장 조건에서 파종시기를 조절하고, 인공기상연구동 정밀유리실에서 입모기간 중 평균기온을 조절하여 검토한 결과는 다음과 같다. 1. 포장조건에서 총체 사료용 벼 품종 및 계통의 m2당 입모수는 파종시기별로 4월 30일 파종에서 낮은 경향을 보였으나 5월 10일~ 6월 9일 파종에서는 비슷하였고, 품종별로는 녹양에 비해 목우와 수원560에서 많은 경향이었다. 평균기온 18 ~ 24oC 범위의 실내시험에서는 총체 사료용 벼의 입모율은 처리온도간 차이가 없었으며, 모든 온도 처리에서 일반형 품종인 일품보다 낮은 경향을 보였다. 2. 파종 후 30일의 초장은 포장시험에서 파종시기가 늦을수록, 실내시험에서 처리온도가 높을수록 길어졌다. 목우와 수원 560은 녹양보다 입모기간 중 기온 상승에 따른 초장 신장 정도가 컸으며, 특히 목우는 초장 신장 효과가 다른 품종에 비해 고온인 24oC에서 높았다. 3. 파종 후 30일의 건물중은 입모기간 중 평균기온 24oC까지는 기온이 높아질수록 모든 품종에서 증가하였다. 반면 기온이 24oC에서 27oC로 상승했을 때의 건물중은 녹양에서는 비슷하였고 목우와 수원560에서는 감소하였는데 특히, 수원 560의 감소 정도가 컸다. 4. 모든 품종에서 묘 충실도는 입모기간 중 평균기온 24oC까지는 온도가 높을수록 증가하였다. 반면 24oC에서 27oC로 상승한 경우 묘 충실도가 모든 품종에서 감소하였는데, 특히 수원560에서 감소 정도가 컸다. 5. 결과적으로, 담수표면산파에서 초기 신장 촉진과 건전한 입모에 가장 효과적인 입모기간 중의 평균기온은 녹양에서 21oC, 목우와 수원560에서 24oC였으며, 수원560의 경우 24oC 이상의 고온에서는 묘가 연약해졌다.
        4,000원
        17.
        2013.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The purpose of asphalt pavement reducing surface temperature by using Pipe cooling system is to make pleasant city life environment. METHODS: We considered building condition to lay the pipes under asphalt pavement and figured out that temperature reducing effect with pipe cooling system. In addition, we guessed rutting through wheel tracking test with a laid the pipes under asphalt mixture and performed fatigue cracking through a flexural fatigue test for performance evaluation of pipe cooling system. RESULTS: When pipe cooling system worked, the temperature of pavement model reduced quickly in test. The system can turn down the degree by 4 or 5 quickly as well. It didn't affect rutting to lay the pipes under the pavement, but it can get damaged to asphalt pavement in early stage by the result of performance evaluation. CONCLUSIONS: We figured out that pipe cooling system can turn down the temperature of aspalt pavement surface through tests. We suggest that pipe cooling system should be considered one of the effective way to solve urban heat island problem.
        4,300원
        18.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        중요 시설해충인 아메리카잎굴파리(Liriomyza trifolii (Burgess))의 개체군 밀도변동모형을 방울토마토 온실내 대기온도와 잎 표면온도를 이용하여 모형 정확성을 비교하였다. 모형 개발에 이용된 생물적 변수들은 기존 발표된 자료들을 사용하였고 모형 작성은 DYMEX 프로그램을 이용하였다. 온도에 따라 상이한 발육기간과 산란수는 생리적 연령으로 표준화시킨 발육완료 분포모형, 연령 특이적 산란수 및 생존율을 비선형회귀 모형에 적합시켜 밀도변동 모형을 개발하였다. 줄내림방식의 방울토마토에서 식물체를 3개의 위치(상단: 지상 1.6 m 이상, 중단: 지상 0.9 - 1.2 m 사이, 하단: 지상 0.3 - 0.5 m 사이)로 나누고 각 위치별로 온실 내 대기 온도와 잎 표면 온도를 기록하였다. 온실 내 잎 표면 최대온도는 대기중 최대온도보다 항상 낮게 유지되고 있었으며, 하단, 상단, 중단의 순으로 온도가 낮아지는 경향을 보였다. 개발된 모형검정을 위한 초기이입 시기와 밀도는 6월초 성충 5마리가 총 50개의 알을 잎에 산란한 것으로 설정하였다. 온실 내 대기 온도와 잎 표면 온도를 이용하여 아메리카잎굴파리 유충 발육모형과 성충의 산란모형을 DYMEX로 프로그래밍하고 모의실험을 하였다. 모의실험결과를 평가하기 위해 기상자료를 수집한 동일한 온실에서 아메리카잎굴파리 유충 밀도를 육안조사 하였으나, 알, 번데기, 성충의 경우 육안조사가 어려워 대상에서 제외하였다. 육안조사결과 밀도변동패턴이 방울토마토 잎 표면 온도를 이용한 모의실험결과 밀도변동패턴과 유사하였다. 육안조사결과와 육안조사시기의 DYMEX모의실험 결과값을 상관분석 한 결과, 육안조사결과와 잎 표면 온도를 이용한 모의실험 결과가 유의한 양의 상관관계를 보였다(r = 0.97, p < 0.01). 대기 온도를 이용한 모의실험 결과와는 유의하지 않은 상관관계를 보였다(r = 0.40, p = 0.18). 본 연구결과 방울토마토 온실에서 아메리카잎굴파리 개체군 밀도변동의 적절한 예측을 위해서는 잎 표면 온도를 고려해야 하는 것으로 나타났다.
        4,000원
        19.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study surveyed and compared the temperatures established in display stands and food surfaces for cold and frozen foods in large discount stores in Korea. The temperatures established in display stands for cold food ranged with 3.5 ± 1.8 ℃ as mean, minimum and maximum were 0 ℃ and 7 ℃ . However, the surface temperatures of cold food on sale ranged with 10.7 ± 2.9 ℃ as a mean, minimum 4.6 ℃ and maximum 18.4 ℃ . Totally, the surface temperature of cold food on sale was 7.2 ℃ , as a mean, higher than established in display stands for cold food in large discount stores in Korea. 53% of the surveyed cold foods were more than 10 ℃ in surface temperature and only 47% was less than 10 ℃ . The differences between temperatures were lowest in fruits, salads and vegetables, but highest in milk products. On the other hand, the temperatures established in display stands for frozen food showed a range with −20.7 ± 1 ℃ as a mean. However, the surface temperatures of frozen food on sale showed a range with −15.4 ±5 ℃ as a mean, minimum −28 ℃ and maximum −4.6 ℃ (included defrosting). The surface temperatures of frozen food,frozen meats, frozen processed foods and ice creams were −13.8 ℃ , −15.9 ℃ , and −16.8 ℃ , respectively. Only 32.3%of surveyed frozen foods showed less than −18 ℃ in surface temperature. In conclusion, the temperatures established on cold and frozen food display stands were less than those of cold and frozen food surfaces on sale. There was also much variation in food surface temperatures during cold and frozen food storage and sales. Therefore, a temperature management system technology use at the distribution level for cold and frozen foods will be developed.
        4,000원
        1 2 3