검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 490

        101.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recycled aggregate is a solution to reduce construction waste and to be environmentally friendly, but concrete using it has various disadvantages in terms of structure. Therefore, the interaction effect of the two materials can be expected by filling the cyclic aggregate concrete in the CFT column. Eighteen specimens were constructed to confirm the compressive behavior of RCFT (Recylced Concrete Filled Tube) columns, which can be applied to real buildings by making high strength concrete with recycled aggregate. Variable is the shape and thickness of steel pipe, concrete strength and mixing ratio, and coarse aggregate and fine aggregate are all used as recycled aggregate. A total of three recycled aggregate concrete preformulations were used to find the optimal mixing ratio and the compressive behavior was analyzed through the load - displacement curves of RCFT columns.
        4,000원
        104.
        2018.04 구독 인증기관 무료, 개인회원 유료
        As buildings are becoming larger, demand for large-scale composite columns for heavy load is increasing. Welded built-up CFT column (ACT Column I) previously developed by authors of this study is structurally stable and economical. Characteristic of welded built-up CFT column is that there is a limitation of cross-sectional size and application of external diaphragm connection to ensure continuity of rib. Then, composite mega column (ACT Column II) was developed to improve limit of cross-sectional size. Composite mega column has a closed cross section like welded built-up CFT column, but thick plate is inserted between cold-formed steel to expand cross section size. However, when external diaphragm connection is applied to composite mega column, amount of steel is increased greatly and interference with finishing material occurs. In this study, internal diaphragm connection is applied through characteristic of composite mega column to which beam flange or stiffener can be attached to plate. In order to analyze this, simple tensile experiment of composite mega column connection with T-shaped stiffener was performed.
        3,000원
        105.
        2018.04 구독 인증기관 무료, 개인회원 유료
        Concrete using recycled aggregate instead of natural aggregate reduces environmental waste and is a future oriented material. However, use of the structure is limited to negative recognition of recycled aggregate quality. In this study, 50 MPa concrete was developed using recycled aggregate. In order to verify the possibility of using as a column member, we aimed to confirm the compressive behavior of RCFT (Recycled Concrete Filled Tube) columns filled with concrete using recycled aggregate. Circular type steel pipe was used, and concrete strength (30, 40, 50MPa) and mixing ratio were the experimental parameters. Through 72 specimen compression tests, 50MPa strength of recycled aggregate concrete was confirmed and stable behavior of 9 RCFT columns was confirmed.
        3,000원
        106.
        2018.04 구독 인증기관·개인회원 무료
        Unlike column-to-beam connections in reinforced concrete frames, column-to-beam connections are generally of the same type. Vertical load (D.L + L.L) and horizontal load (wind load, seismic load) are not the same in the upper and lower flange stress history. In the case of beams bonded to synthetic CFT columns, the tensile force is transmitted through the steel pipe column, and the compressive force is transmitted to the filled concrete, so the seismic performance is excellent even if the column has a relatively thin cross section. Also, in case of beam the composite CFT column, tensile force is taken by the steel pipe column, and the compressive force is caught by the inner concrete, and the shape of the column joint can be changed. In this study, the stress distribution of buildings is investigated according to the size and characteristics of the building, and the load history of the upper and lower flanges according to the building type is checked to show the structural possibility of the Asymmetric Diaphragms joint.
        107.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study develops numerical model of mega composite columns in fire and investigates the residual areas using 500℃ isotherm method and residual capacity of mega composite columns after 3 hours. In order to perform heat transfer analysis, thermal properties of steels and concrete were adopted from Eurocodes. In addition to, the temperature distributions of composite columns with respect to fire tests were compared with numerical analysis results. As a result, residual capacity of mega composite column with 1m width remained more than 45%. The residual capacity of mega composite column was only increased to 2.3∼2.6% with the use of additional rebars.
        4,000원
        108.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As buildings are becoming larger, demand for mega-sized composite columns (over 1-meter diameter) is increased. We have developed and commercialized welded built-up CFT column (ACT Column I) since 2005 which are structurally stable and economical using cold-formed steel with rib. However, there has a limit in size of cross section (618˟618mm) by a fabrication facilities. And due to characteristics of closed cross section, there has a limit to construction of connection of moment frame. Composite mega column (ACT Column II) has same concept of forming closed cross section. But in order to enlarge cross sectional size, thick plate is inserted between cold-formed steels. Since composite mega column can control thickness and width of thick plate, steel or composite beams can be directly attached to the connection. In this study, we propose strength formula of composite mega column to beam connections with T-shaped stiffener as internal diaphragm and verified through finite element analysis and simple tensile experiment.
        4,000원
        109.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        해양환경의 극한 환경조건에 노출 된 고정식 및 부유식 해양구조물의 안전성과 설계비용 효율성에 있어서 파랑-구조물 상 호작용의 정확한 예측은 중요하다. 본 연구에서는 규칙파 중 원형 기둥에 대한 파랑-구조물 상호작용을 해석하였다. 3차원 이상유동 (two-phase flow)을 해석하기 위해 오픈소스 전산유체역학 라이브러리인 오픈폼을 사용하였다. 4개의 원형기둥이 정사각형 배열을 이루 고 있을 때 규칙파의 입사각도에 따른 상호작용을 해석하였다. 원형 기둥 구조물에서의 wave run-up을 입사파의 기울기에 따라 비교하 였다. 원형 기둥과 입사파의 상호작용으로 인해 원형 기둥 사이에 높은 파가 생성되는 것을 확인하였다. 본 해석 결과는 구조물과 입 사파의 상호작용에 의한 air gap에 대한 연구의 기초자료로 활용될 것으로 기대된다.
        4,000원
        110.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문은 선교적 교회론이 한국적 상황에서 실제로 어떻게 실천되 고 있는지를 알아보고, 그들이 가지고 있는 공통적인 특징들로부터 선교적 교회를 이루는 일곱 가지 주요 요소들을 정리한다. 첫째, 선교지 로서의 지역사회(Local community as mission field)이해. 둘째, 보냄받은 공동체(The Sent-Community)로서의 교회이해. 셋째, 통전적 선교사역(Holistic Mission). 넷째, 하나님의 선교(missio Dei). 다섯째, 하나님의 나라(Kingdom of God). 여섯째, 하나님의 한 백성이 함께 이끌어 가는 팀 리더십 교회구조(Laos-Driven Structure). 일곱째, 선교사로서의 하나님 나라 백성들(God’s Missionary People)이다. 이것들은 오늘날 한국교회들이 선교적 교회 로 다시 세워지기 위해서 꼭 갖춰야 할 필수요소들이 무엇인지에 대한 선교적 통찰을 준다. 선교적 교회는 교회의 선교적 본질을 회복하고, 하나님으로부터 세상으로 보냄을 받은 선교 공동체라는 자기 정체성을 가지고 이 땅에 임하는 하나님의 나라(통치)를 위해 통전적 선교사역을 수행하는 사명 공동체인 것이다.
        8,000원
        111.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study presents a sustainable design method to optimize the embodied energy and CO2 emission complying with the design code for reinforced concrete column. The sustainable design method effectively achieves the minimization of the environmental load and energy consumption whereas the conventional design method has been mostly focused on the cost saving. Failure of reinforced concrete column exhibits compressive or tensile failure mode against an external force such as flexure and compression; thus, optimization analyses are conducted for both failure modes. For the given sections and reinforcement ratios, the optimized sections are determined by optimizing cost, embodied energy, and CO2 emission and various aspects of the sections are thoroughly investigated. The optimization analysis results show that 25% embodied energy and 55% CO2 emission can be approximately reduced by 10% increase in cost. In particular, the embodied energy and CO2 emission were more effectively reduced in the tensile failure mode rather than in the compressive failure mode. Consequently, it was proved that the sustainable design method effectively implements the concept of sustainable development in the design of reinforced concrete structure by optimizing embodied energy consumption and CO2 emission.
        4,000원
        112.
        2017.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To investigate the cyclic characteristics of the retrofitted exterior joints of RC frame with haunch, 70% scaled 6 beam-column exterior joint subassemblies were designed according to design guideline according to 1988 and tested with cyclic loading up to 3.5% story drift ratio. During the experiments axial forces are applied to columns to simulate gravity load. Experimental results shows that the strength of retrofitted specimens was increased steadily until 2.5% story drift ratio and their strengths increased more than 1.7 times of the non-retrofitted in case that main bar was bent away from exterior joint. The joint strength and effective stiffness of the retrofitted specimen was increased and results in more deformation capacity compared to the non-retrofitted.
        4,000원
        113.
        2017.04 구독 인증기관·개인회원 무료
        As the ridges become larger and larger, a structural type that enables effective utilization of the long span and space is required. In the construction stage, the steel column supports the installation load. However, in order to secure the stability against the out - of - plane deformation of the steel column due to the lateral pressure when the concrete is laid, a binding frame is installed inside the steel pipe at constant intervals to resist the concrete installation pressure. When the concrete is cured and its performance as a composite section is exerted, a stress is generated which pushes the steel pipe out of the plane by the column compressive force. In this case, since the binding frame controls the deformation, the local buckling is delayed and the constraining effect on the concrete is increased. In order to evaluate the structural performance and behavior of the composite mega column according to the eccentricity effect and the effect of the binding frame, we carried out a structural test by fabricating eight monopole specimens with the binding frame reinforcement, reinforcing gap, reinforced cross section and eccentricity , And the experimental results are compared with the KBC2016 design formula.
        114.
        2017.04 구독 인증기관 무료, 개인회원 유료
        The utilization of composite columns is increasing due to the construction of high-rise buildings and large buildings. The commercially available concrete chimney steel column (ACT I) is a stable and economical structure, but there is a limit in the section size to be applied to a composite column subjected to a high load. We have developed a composite mega column with an integral structure by adding a plate to the central part of the ACT I column and installing a binding frame at a certain interval inside the central plate. In this study, to evaluate the compressive performance of the composite mega column, four test specimens were constructed with binding frame reinforcement, reinforcement spacing, and reinforced cross - sectional area. The structural performance of the composite section is compared with that of KBC2016 to evaluate the behavior of the specimen.
        3,000원
        115.
        2017.04 구독 인증기관·개인회원 무료
        The paper presents an experimental evaluation of RC columns retrofitted by TRC(Textile fabric Reinforced Concrete). TRC were made using textile fabric fiber and self leveling mortar. A total of three specimens was constructed and was performed cyclic loading test. One specimen was a non-retrofitted column, while others were retrofitted with textile fabric and sheet type fiber. By comparing with non-retrofitted specimen, the maximum strength and ductility of retrofitted RC column was improved compared to non-retrofitted RC column.
        116.
        2017.04 구독 인증기관·개인회원 무료
        This study develops numerical model of mega composite columns in fire and investigates the residual areas below 500℃ after 3 hours. In order to perform heat transfer analysis, thermal properties of steels and concrete were adopted from Eurocodes. In addition to, the temperature distributions of composite columns with respect to fire tests were compared with numerical analysis results. As a result, the residual areas below 500℃ of mega composite columns were evaluated.
        117.
        2017.04 구독 인증기관·개인회원 무료
        This paper investigated impact resistance capacity and failure mode of strengthened column with PROTECT (Poly-Resilience-Oriented hybrid TEChnology plaTe) panel by analytical study. PROTECT panel is the composite panel with two steel plates and nano-composite. In order to perform impact analysis, dynamic properties of concrete, steels and nano-composite were determined. Finite element analysis was performed with these properties under the drop-weight impact. From the FEA, different failure modes corresponding to different columns were derived.
        119.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Composite columns are increasingly used due to the construction of super-tall buildings and large-scale buildings. Studies on the shapes of and construction technologies for structural members using steel tubes are being conducted actively. Welded built-up CFT columns previously developed and commercialized by the authors of this study (ACT-1 columns) are structurally stable and economically efficient. However, the 1m limit in the width of the columns and their small interior spaces impose a difficulty in installing reinforcing materials and thus deteriorate the ease and efficiency with which they are constructed. This study suggests placing thick plates at the centers of the surfaces of the existing ACT-1 column and installing a binding frame (binding frames) at the central thick plates to enhance the integrity and resist lateral pressure caused by concrete casting. Finite element analysis was conducted with the variables of the number and cross-sectional size of the binding frame and the cross-sectional size of the steel tube to estimate the structural behavior of the steel tubes. Hydraulic tests were conducted to analyze load-displacement relations and identify the influence of the binding frames on the relations. The variables in the tests were the number and cross-sectional size of the binding frame, welding details, column joint and the cross-sectional size of the steel tube
        4,000원
        120.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When reinforcing an existing reinforced concrete beam-column building with a precast concrete panel, special connection between the PC member and the RC member is required to solve the time dependent deformation of the RC member and to receive the large shear forces. The aim of this study is to obtain the shear strength of upper connection between the existing RC beam-column and infilled PC wall panels in experimentally and theoretically. Thus, the static shear loading tests were conducted on the 6 specimens with the plate connection. Shear failure was resulted from the weakest portion of interior PC panel, exterior RC, and the connection, when the PC portion which located at the center of specimen was pulled upward from the bottom. T he experimental result was compared with analytical result from ACI 318M-14 Chapter 17 for the shear strength of post-installed anchor and PCI Handbook 7th edition 6.8 Structural Steel Corbel (PCI Design Handbook 7th edition, 2010) for the strength of cast-in H-beam. The analytical and experimental results show final failure at the same location. The failure loading of experiment showed larger than average 6% to that of the analysis.
        4,500원