검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 233

        41.
        2017.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Seismic analyses of a pile under a large rigid basement foundation embedded in the homogeneous soil layer were performed practically by a response displacement method assuming a sinusoidal wave form. However, it is hard to take into account the characteristics of a large mat foundation and a heterogeneous soil layer with the response displacement method. The response displacement method is relevant to the 2D problems for longitudinal structures such as tunnel, underground cave structure, etc., but might not be relevant with isolated foundations for building structures. In this study, seismic pile analysis by a pseudo 3D finite element method was carried out to compare numerical results with results of the response displacement method considering 3D characteristics of a foundation-soil system which is important for the building foundation analyses. Study results show that seismic analyses results of a response displacement method are similar to those of a pseudo 3D numerical method for stiff and dense soil layers, but they are too conservative for a soft soil layer inducing large soil pressures on the foundation wall and large pile displacements due to ignored foundation rigidity and resistance.
        4,000원
        42.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 축산관련차량에 적재물질을 상하차 할 때 발생하는 적재하중을 측정 할 수 있는 로드셀을 개발하고, 개발 로드셀의 성능을 평가한 것이다. 축산관련차량의 차체 하단에 평행 판스프링은 하중이 적재함에 따라 변위가 발생하며, 발생 변위를 개발 로드셀로 측정하여 하중 데이터를 수신하였다. 실험을 위해 실제 차량의 평행 판스프링을 이용하여 실험용 지그를 설계하였고, 실제하중은 프레스(press)를 통해 조성하였다. 실험은 하중이 선형적으로 측정되는지 확인하기 위한 직진성 테스트와 평행 판스프링의 복원력을 확인하기 위해 하중의 증·감소를 통한 히스테리시스 테스트를 진행하였다. 실험결과는 실제하중과 로드셀을 통해 측정한 하중은 비교적 차이를 나타냈지만, 일부 보정을 통해 정확도를 향상 시킬 수 있을 것으로 판단된다. 히스테리시스 테스트의 경우 하중이 감소할 때 평행 판스프링의 탄성으로 인한 오차 발생은 추가적인 센싱을 통해 수정이 필요할 것으로 판단된다.
        4,000원
        43.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Building hardware joints are welded in most cases, which have risks of fire and explosion. Besides, the secondary damage of the destruction of the welded parts can be caused by the horizontal displacement of the structure due to earthquake or wind load. This paper compared the horizontal displacement following abilities of welded building hardware and non-welded building hardware. To do this, We conducted actual formation shake table test, and checked on the horizontal displacement following ability of structure by comparing their responses to earthquake load. We made the 2m-high framework to examine the responses of the actually constructed building hardwares, and analyzed the displacement responses of the welded-typed, non-welded-typed, and cruciform bracket building hardwares. We conducted the test by increasing acceleration rate until displacement reached 40mm corresponding to allowable relative story displacement II. The result of the test showed that the building hardware using welding work made cracking and breakage on welded connections of welded building hardware, but non-welded building hardware with no use of welding work and cruciform bracket building hardware make no problem, and that non-welded building hardware is superior to that of the welded building hardware in the horizontal displacement following ability due to earthquake or wind load.
        4,000원
        44.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, time and frequency domain characteristics of Gyeong-ju earthquakes were investigated, and nonlinear time history analyses were conducted for bi-linear hysteretic structures excited by short-duration ground accelerations. Previous studies showed that larger inelastic displacements than the peak displacement of the corresponding elastic system were observed especially for the structures with structural period shorter than 0.3s, and the similar results could be obtained when long-duration ground accelerations were used as excitation loads. For the short-duration earthquakes, however, the inelastic displacements were not so large and almost identical to the peak elastic displacements.
        4,000원
        45.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 마커없이 구조물의 변위를 측정할 수 있는 영상기반 변위계측 시스템(NVDMS)을 제안한다. 기존의 방식 과 제안하는 NVDMS는 크게 두 가지의 차이점이 있다. 첫째, NVDMS는 마커를 사용하지 않고 구조물의 특징점의 픽셀좌 표 변화를 추출한다. 둘째, 특징점의 픽셀좌표를 물리좌표로 변환하는 scaling factor는 기존 방식에선 마커의 크기로부터 계 산되는 반면, NVDMS에서는 카메라와 구조물사이의 거리, 각도, 초점거리로 계산된다. 3층 축소모형의 자유진동 실험에서 제안한 NVDMS로부터 얻은 변위데이터의 신뢰도를 분석하기 위해 LDS로부터 얻은 변위데이터의 비교를 하였으며, 얻어진 변위데이터를 이용하여 동특성을 분석하였다. 분석결과 NVDMS는 마커없이 구조물의 동적변위를 정밀하게 측정가능할 뿐 만 아니라 얻어진 변위데이터로부터 추출한 동특성의 신뢰도 또한 높았다.
        4,000원
        46.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 마커없이 구조물의 변위를 측정할 수 있는 영상기반 변위계측 시스템(NVDMS)을 제안한다. 기존의 방식과 제안하는 NVDMS는 크게 두 가지의 차이점이 있다. 첫째, NVDMS는 마커를 사용하지 않고 구조물의 특징점의 픽셀좌표 변화를 추출한다. 둘째, 특징점의 픽셀좌표를 물리좌표로 변환하는 scaling factor는 기존 방식에선 마커의 크기로부터 계산되는 반면, NVDMS에서는 카메라와 구조물사이의 거리, 각도, 초점거리로 계산된다. 3층 축소모형의 자유진동 실험에서 제안한 NVDMS로부터 얻은 변위데이터의 신뢰도를 분석하기 위해 LDS로부터 얻은 변위데이터의 비교를 하였으며, 얻어진 변위데이터를 이용하여 동특성을 분석하였다. 분석결과 NVDMS는 마커없이 구조물의 동적변위를 정밀하게 측정가능할 뿐만 아니라 얻어진 변위데이터로부터 추출한 동특성의 신뢰도 또한 높았다.
        4,000원
        47.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        착빙 및 착설에 의한 송전선의 갤로핑 발생 메커니즘의 규명을 위해 본 연구에서는 실제규모의 송전선 풍진동 모사를 가능 하게 하는 실험방법과 실험장치를 개발하였다. 개발된 실험장치는 8줄의 탄성와이어로 지지되는 송전선단면 모형으로 구성되며, 수직 , 수평 및 비틀림 방향으로 저주파수에서 큰 변위의 진폭으로 진동이 가능하다. 풍동실험을 통하여 본 실험방법의 유효성을 확인 하였고 실제 송전선의 갤로핑현상의 재현이 가능하다는 것을 알 수 있었다.
        4,000원
        48.
        2016.04 구독 인증기관·개인회원 무료
        Displacement response of structure is valuable information for monitoring an structure integrity. However, measuring the displacement response is difficult than other structure responses, such as acceleration, strain, and angle. So, previous researches have focused on displacement estimation technique using measured acceleration. The displacement estimation methods also have weakness that filtering noise of measured data is so complicate. The estimated displacement might be diverged because of the measuring noise. Because of these reasons, this study focused on rotation angle. This study developed a algorithm for estimating displacement and structure deformed shape using rotation angle.
        49.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 온실시공 및 유지관리 지침마련을 위한 기초자료로 사용하기 위하여 플라스틱 필름 온실의 구조재를 대상으로 휨 시험을 실시한 후, 하중-변위의 관계를 검토하였다. 그 결과 시편의 형상 에 관계없이 시편의 규격이 클수록 항복 및 최대하중이 큰 경향을 보였으며, 변위도 동일한 양상을 보 였다. 강관이 각관보다 항복 및 최대하중은 적게 나타났으며, 변위는 크게 나타났으며, 강관의 경우는 항복 및 최대하중 하에서의 변위는 각각 1.42~4.20mm 및 5.80~24.13mm정도의 범위에 있었다. 각관 의 경우에 변위는 각각 1.62~3.00mm 및 3.13~8.01mm정도의 범위였다. 그리고 본 시험의 결과와 기 존의 연구에서 제시한 기준 값들을 보면, 동일한 부재임에도 불구하고 부재들이 사용되는 온실형태나 사용목적(예, 샛기둥)에 따라 큰 차이가 있음을 알 수 있었다. 또한 유리온실인 와이드 스팬 및 벤로 형 을 대상으로 제시하고 있는 경우(, )에도 변형이 각각 28.0mm 및 35.0mm(기둥 길이 280cm 적용)정도로서 네델란드의 유리온실 표준 기준(14.0mm)과 비교해도 큰 차이가 있었다. 스팬 이 60cm인 경우, 주서까래나 도리 부재의 본 시험결과는 기존의 연구에서 제시한 값들 보다 각각 55.7% 및 39.3%정도 크게 나타났다. 그리고 기둥의 경우, NEN의 기준 값인 14.0mm와 비교해서 본 시험결과는 43.7%정도 적은 것으로 나타났다. 따라서 변위제한은 온실의 종류나 형태 및 규격 등 다양 한 요인에 의해서 다를 수 있기 때문에 이들 요인들을 반영한 연구나 시험들을 진행하여 온실 시공 및 유지관리 등에 반영할 수 있도록 하여야 할 것으로 판단되었다.
        4,000원
        50.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        미국 AASHTO LRFD(AASHTO, 2012)나 국내의 도로교설계기준(2012)의 차랑충돌에 대한 교각설계기준을 참조하면 교각 설계 시 차량충돌에 대해 정적인 하중을 고려하도록 제시하고 있다. 한편 2003년 미국 네브래스카 주에 트럭이 교각에 충돌하여 교각 및 교량 상부구조가 붕괴되는 사고가 발생하는 등 차량충돌에 의한 교량붕괴사고는 홍수에 의한 교량붕괴사고에 이은 두 번째 요인으로 분류되기도 한다. 화물차량의 대형화와 도로시스템의 개선으로 인하여 이러한 사고가 발생할 가능성이 중가하고 있다고 볼 수 있다. 본 연구에서는 교각 설계시 차량충돌에 대한 동적 해석을 수행하게 되면 많은 비용과 시간이 소요되어 실용적인 측면에서 연구결과가 쉽게 반영되지 못하고 있으므로 충돌해석 비용과 시간을 저감할 수 있는 모델축소법(model reduction)을 이용한 해석방법을 개발하였으며 그 효용성을 최종변위에 대해 직접충돌해석결과와 비교함으로써 평가하였다.
        4,000원
        51.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: It is difficult to estimate tunnel stability because of lack of timely information during tunnel excavation. Tunnel deformability refers to the capacity of rock to strain under applied loads or unloads during tunnel excavation. This study was conducted to analyze a methods of pre-evaluation of stability during tunnel construction using the critical strain concept, which is applied to the results of tunnel settlement data and unconfined compression strength of intact rock or rock mass at the tunnel construction site. METHODS: Based on the critical strain concept, the pre-evaluation of stability of a tunnel was performed in the Daegu region, at a tunnel through andesite and granite rock. The critical strain concept is a method of predicting tunnel behavior from tunnel crown settlement data using the critical strain chart that is obtained from the relationship between strain and the unconfined compression strength of intact rock in a laboratory. RESULTS: In a pre-evaluation of stability of a tunnel, only actually measured crown settlement data is plotted on the lower position of the critical strain chart, to be compared with the total displacement of crown settlement, including precedent settlement and displacement data from before the settlement measurement. However, both cases show almost the same tunnel behavior. In an evaluation using rock mass instead of intact rock, the data for the rock mass strength is plotted on the lower portion of the critical strain chart, as a way to compare to the data for intact rock strength. CONCLUSIONS : From the results of the pre-evaluation of stability of the tunnel using the critical strain chart, we reaffirmed that it is possible to promptly evaluate the stability of a tunnel under construction. Moreover, this research shows that a safety evaluation using the actual instrumented crown settlement data with the unconfined compression strength of intact rock, rather than with the unconfined compression strength of a rock mass in the tunnel working face, is more conservative.
        4,000원
        52.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        변위전류 측정법을 L-α-dilauryl phosphatidylcholine(DLPC) 단분자 막의 연구에 적용하였 다. 변위전류는 물 표면에서 DLPC 단분자 층에서 압축과 확장에 의해 발생되었다. 맥스웰 변위전류 (MDC) 발생은 분자 당 점유면적 200 Å2 에서 40 Å2에 대하여 관찰하였다. 맥스웰 변위전류는 단분 자 층의 압축 사이클에 대해 조사하였으며, MDC의 최대 값은 압축 사이클의 표면 압력이 처음 상승하 기 바로 직전의 분자당 점유면적에서 나타나는 것을 알 수 있었다. LB막의 단분자층 표면 형태는 원자 힘 현미경(AFM)으로 측정하였다. 결과적으로, AFM 이미지에 나타난 LB막의 특성은 단분자 층의 배향 이 좋았으며 단분자 층의 두께는 약 5~10 nm였다.
        4,000원
        53.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper introduces a digital image processing(DIP) method as a method for measuring the displacement of pylon. The comparison of DIP results and ANSYS analysis results verified the validity of the image processing technique. Normalized cross-correlation(NCC) coefficient was used and experiments were performed three times. It shows that the displacement difference was 22% and 5% compared to ANSYS results. Therefore, the image processing method is expected to be able to measure the displacement of pylon sufficiently.
        4,000원
        54.
        2014.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        There has been an increasing demand for introducing a base isolation system to secure the seismic safety of a nuclear power plant. However, the design criteria and the safety assessment methodology of a base isolated nuclear facility are still being developed. A performance based design concept for the base isolation system needs to be added to the general seismic design procedures. For the base isolation system, the displacement responses of isolators excited by the extended design basis earthquake are important as well as the design displacement. The possible displacement response by the extended design basis earthquake should be limited less than the failure displacement of the isolator. The failure of isolators were investigated by an experimental test to define the ultimate strain level of rubber bearings. The uncertainty analysis, considering the variations of the mechanical properties of isolators and input ground motions, was performed to estimate the probabilistic distribution of the isolator displacement. The relationship of the displacement response by each ground motion level was compared in view of a period elongation and a reduction of damping. Finally, several examples of isolator parameters are calculated and the considerations for an acceptable isolation design is discussed.
        4,000원
        55.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        고층 건축물의 내풍설계 시 다차모드 해석의 수행이 필요하다. 고층건축물의 다차모드 해석을 위해서 풍압적분법과 1차모드 해석을 수행하였으며, 풍압적분법을 활용하여 층별 시간이력 전도모멘트를 산출하였다. 층별 전도모멘트를 산출하기 위해 풍압적분법을 활용하였고, 그 방법으로 임의의 층까지의 누적 풍력데이터로부터 층별 시간이력의 전도모멘트를 산출하였다. 풍응답변위는 각 층별 전도모멘트로부터 1차 모드 해석을 수행하여 평가하였다. 본 연구 결과의 그 유효성을 높이기 위해, 건축물 전체에 작용하는 풍력데이터에 의해 얻어진 풍응답 결과와 비교하였다. 두 연구 결과는 유사한 것으로 나타났다.
        4,000원
        58.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study carried out finite element deflection analysis of cylindrical shell structures made of composite materials, which is based on the micro-mechanical approach for different fiber-volume fractions. The finite element (FE) models for composite structures using multi-scale approaches described in this paper is attractive not only because it shows excellent accuracy in analysis but also it shows the effect of the material combination. New results reported in this paper are focused on the significant effects of the fiber-volume fraction for various parameters, such as fiber angles, layup sequences, and length-thickness ratios. It may be concluded from this study that the combination effect of fiber and matrix, largely governing the dynamic characteristics of composite shell structures, should not be neglected and thus the optimal combination could be used to design such civil structures for better dynamic performance.
        4,000원
        59.
        2013.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        백두산에서는 2002년부터 화산성 지진활동의 증가, 정밀 수준측량 관측을 통한 지표면 팽창, 특정 화산가스 방출량의 증가, 온천수의 온도 증가 등 화산 전조활동이 활발해짐으로써 나타나는 전조현상들이 관측되었다. 이러한 관측결과 중 정밀 수준측량 데이터를 활용한 백두산 천지 칼데라 주변의 수직, 수평 지표변위 경향 분석을 통해 2002년 이후 2009년까지 지표가 팽창하는 경향을 나타냄으로써 백두산 지하 마그마 챔버의 부피가 증가하였음을 확인할 수 있었다. 이후 2010년을 기점으로 지표가 수축하는 경향을 나타내기도 하였으나 이후 다시 팽창하는 경향을 나타냄을 확인할 수 있었다. 북측 사면에서 2002년부터 2003년까지 칼데라 외륜산 일대의 지표면이 46.33 mm 융기 팽창한 것을 바탕으로 지하 마그마 챔버의 부피 변화량을 계산해 보면, 약 0.008 km3 (7.7-8.0×106m3)의 부피가 증가한 것으로 계산되었다. 이는 백두산 산정부로부터 지하 약 5 km 지점에 천처 마그마 챔버가 형성되고 0.008 km3의 마그마가 주입된 것으로 해석된다.
        4,000원
        60.
        2013.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 일체식 교대 교량의 장대화 및 내진성능 향상을 위해 가장 중요한 역할을 하는 교대-H형 강말뚝 연결부의 성능을 향상시키기 위하여 기존의 연결부의 균열형상을 파악하고, 이를 기반으로 새로운 형태의 연결부를 제안하기 위하여 철근을 활용하여 강성을 증가시키는 방법과 강말뚝의 형상을 개선하여 연성을 개선시키는 방법을 모색하였다. 먼저, 기존 연결부의 성능을 향상시키기 위하여 연결부 주변에 PennDOT에 규정된 철근상세와 나선철근의 배치와 HSS 튜브를 사용하였으나, PennDOT의 철근 상세와 HSS 튜브는 연결부의 성능을 향상시키지 못 했으나, 나선철근은 균열을 효과적으로 차단시키는 것을 확인할 수 있었다. 하지만, 철근의 구속효과로 인해 강말뚝의 저항력이 변위에 선형적으로 비례하여 증가하므로 교량의 상부구조에 축력을 발생시키는 효과를 가져왔다. 따라서, 강말뚝의 형상을 개선하기 위하여 콘크리트 교대에 매입된 부분의 플랜지를 제거하는 방법과 콘크리트 외부에서 플랜지의 폭을 축소시키는 형태를 검토하였다. 두 가지 방안 모두 균열을 억제하는데 효과적인 방법이었으나, 플랜지를 제거하는 쪽의 연결부가 더욱 효과적이었다.
        4,000원
        1 2 3 4 5