검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 110

        23.
        2015.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The tsunami hazard analysis is performed for testing the application of probabilistic tsunami hazard analysis to nuclear power plant sites in the Korean Peninsula. Tsunami hazard analysis is based on the seismic hazard analysis. Probabilistic method is adopted for considering the uncertainties caused by insufficient information of tsunamigenic fault sources. Logic tree approach is used. Uljin nuclear power plant (NPP) site is selected for this study. The tsunamigenic fault sources in the western part of Japan (East Sea) are used for this study because those are well known fault sources in the East Sea and had several records of tsunami hazards. We have performed numerical simulations of tsunami propagation for those fault sources in the previous study. Therefore we use the wave parameters obtained from the previous study. We follow the method of probabilistic tsunami hazard analysis (PTHA) suggested by the atomic energy society of Japan (AESJ). Annual exceedance probabilities for wave height level are calculated for the site by using the information about the recurrence interval, the magnitude range, the wave parameters, the truncation of lognormal distribution of wave height, and the deviation based on the difference between simulation and record. Effects of each parameters on tsunami hazard are tested by the sensitivity analysis, which shows that the recurrence interval and the deviation dominantly affects the annual exceedance probability and the wave heigh level, respectively.
        4,000원
        30.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Many countries have introduced new imported food safety measures, following the accident at Fukushima Daiichi Nuclear Power Station. This study was conducted to evaluate the measures contents and effects on food trades values. Eight percent of members were notified the introduced measures to the World Trade Organization. The measures’ contents were banning imports, enhancing inspection and adding certification requirement. The covered regions were some prefectures, entire Japan or all affected countries. European Union introduced a measure that subjecting foods originating from 12 prefectures to import at designated ports with required certification. The measures were amended 8 times until March 2014 to apply listed foods from 15 prefectures. The trade value of fishery products and miscellaneous foods were affected. Australia introduced a measure that required additional inspection of dairy, fishery and plants products from 13 prefectures with subsequent amendments. The trade value had no effect in tested foods. Chinese Taipei introduced a temporary import ban for all foods from 6 prefectures. Trade values for fruits were affected. The United States issued an import alert for detention without examination for listed prefectures and goods without introducing new measures. Although no specific products were affected, trade values for all foods were affected.
        5,100원
        36.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study presents a structural safety analysis method for a plant annunciator panel under the seismic effect. Seismic qualification analysis for the nuclear plant annunciator panel is carried out to confirm the structural integrity and the results are represented by required response spectra. For the numerical analysis, finite element method is adopted. Mode combinations are also used to obtain the reliability of the spectrum analysis. The analysis results shows that the nuclear plant annunciator panel is designed as a dynamically rigid assembly, without any resonance frequency blow 33Hz. The calculated stress of the nuclear plant annunciator panel is much less than yield stress of used steel.
        4,000원
        39.
        2013.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, dynamic characteristics and seismic capacity of the nuclear power plant piping system are evaluated by model test results using multi-platform shake table. The model is 21.2 m long and consists of straight pipes, elbows, and reducers. The stainless steel pipe diameters are 60.3 mm (2 in.) and 88.9 mm (3 in.) and the system was assembled in accordance with ASME code criteria. The dynamic characteristics such as natural frequency, damping and acceleration responses of the piping system were estimated using the measured acceleration, displacement and strain data. The natural frequencies of the specimen were not changed significantly before and after the testing and the failure and leakage of the piping system was not observed until the final excitation. The damping ratio was estimated in the range of 3.13 ~ 4.98 % and it is found that the allowable stress(345 MPa) according to ASME criteria is 2.5 times larger than the measured maximum stress(138 MPa) of the piping system even under the maximum excitation level of this test.
        4,200원
        40.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Involved in a research for the application of seismic isolation to the nuclear industry, this study evaluates firstly the responses of seismic isolation system considering general ranges of structural period and damping ratio by using preliminary design formula. Secondly, coupling effects of input motions were evaluated to find out appropriate conditions of excitations and effect of the iteration for calculating yield displacement of lead core was also assessed in terms of response of a seismically isolated structure. Finally, the results of preliminary design calculation were compared with those of dynamic analysis and the propriety of the formula was evaluated and appropriate ranges of reduction factor were also suggested from the results.
        4,000원
        1 2 3 4 5