검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 98

        41.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is for a pipe cutting apparatus for use in a process of a pipe. The system refers to a novel structure comprised of a main bed, a feeder part and a cutter part. The feeder part is comprised of an AC servo motor unit, a feeding gear unit, a LM guide and a rail. The cutter part is comprised of a blade unit consisting of a blade for cutting, a AC servo motor to rotate the blade unit and a clamp unit to fix the pipe. This study proposes a mechanism of a product by designing the system and analyzes the cutting power. This study will be used as basic data for the design by analyzing the vibration and the structure
        4,000원
        42.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The experimental study for an operational characteristics and performance of the sodium heat pipe were carried out. For an experiment, the heat pipe which is 1000mm length and 25.4mm diameter of stainless steel container with 50 mesh of screen wick using sodium as a working fluid is manufactured and tested as functions of heat flow rate, inclined angle and operating temperature. The test results are as follows. During the start-up, frontal start up was observed because of the vapor density increasing as increased the hot zone. Also, the heat pipe showed uniform temperature over than 420℃ of the operating temperature. The average heat transfer coefficient increased as the heat flux and the vapor temperature increase, and the range of the total thermal resistance was 0.075~0.04℃/W at the 12~53.55kW/m2 of heat flux and 500~750℃ of operating temperature. The maximum heat flow rate was 750W at the 10 degree of top heating mode.
        4,000원
        43.
        2013.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Real-time data reduction pipeline for the Korea Microlensing Telescope Network (KMTNet) was developed by Korea Astronomy and Space Science Institute (KASI). The main goal of the data reduction pipeline is to find variable objects and to record their light variation from the large amount of observation data of about 200 GB per night per site. To achieve the goal we adopt three strategic implementations: precision pointing of telescope using the cross correlation correction for target fields, realtime data transferring using kernel-level file handling and high speed network, and segment data processing architecture using the Sun-Grid engine. We tested performance of the pipeline using simulated data which represent the similar circumstance to CTIO (Cerro Tololo Inter-American Observatory), and we have found that it takes about eight hours for whole processing of one-night data. Therefore we conclude that the pipeline works without problem in real-time if the network speed is high enough, e.g., as high as in CTIO.
        4,000원
        44.
        2013.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The purpose of asphalt pavement reducing surface temperature by using Pipe cooling system is to make pleasant city life environment. METHODS: We considered building condition to lay the pipes under asphalt pavement and figured out that temperature reducing effect with pipe cooling system. In addition, we guessed rutting through wheel tracking test with a laid the pipes under asphalt mixture and performed fatigue cracking through a flexural fatigue test for performance evaluation of pipe cooling system. RESULTS: When pipe cooling system worked, the temperature of pavement model reduced quickly in test. The system can turn down the degree by 4 or 5 quickly as well. It didn't affect rutting to lay the pipes under the pavement, but it can get damaged to asphalt pavement in early stage by the result of performance evaluation. CONCLUSIONS: We figured out that pipe cooling system can turn down the temperature of aspalt pavement surface through tests. We suggest that pipe cooling system should be considered one of the effective way to solve urban heat island problem.
        4,300원
        45.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 산업용 열교환기 및 상용 파이프의 최적 설계를 위하여 열교환기 내의 사각형 단면 파이프의 shear-thickening 비뉴톤 유체의 압력강하 및 대류 열전달률을 수치해석적으로 수행하였다. shear-thickening 유체의 구성 방정식은 기존의 비뉴톤 유체 멱법칙을 보완한 확장 멱법칙 모델을 채택하였다. 파이프 내의 압력강하를 의미하는 마찰계수와 확장 레이놀즈 수의 곱은 기존 연구의 비교자료와 비교할 때 뉴톤 유체 영역과 멱법칙 영역에서 각각 0.018% 및 0.06% 내에서 일치함을 보였고, 대류 열전달률을 의미하는 뉴셀트 수는 문헌치와 비교할 때 뉴톤 유체 영역과 멱법칙 영역에서 각각 0.025% 및 0.14% 내에서 일치함을 보였다. 비뉴톤 확장 멱법칙 유체 모델의 형태를 띠는 shear-thickening 유체를 열교환기 또는 상용파이프 내의 사각형 단면 파이프 내에서 사용하면 유동지수(n)에 따라서 뉴톤 유체보다 최대 160%의 압력강하를 증가시켰고 최대 14%의 대류 열전달 감소를 발생시킬 수 있었다.
        4,000원
        46.
        2011.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This carbon nano heating system was consisted of power supply equipment, a carbon fiber and a stainless flexible hose. carbon nano heating system was manufactured by carbon fiber of a power capacity 30kw/h and light-oil hot air heater in control plot was the heating capacity 30,000kcal/h, As the result, Temperature difference due to carbon nano heating system and hot air heater in greenhouse showed that air temperature at experimental greenhouse, comparison greenhouse were 14.8℃, 13.4℃ respectively. It was found that carbon nano heating system and light-oil hot air heater heating cost were 1,095,740won, 2,683,628won. therefore as heating cost saving 60%. Yield of tomatoes cultured in greenhouse using carbon nano heating pipe was 4% inclease. Economic analysis comparison between the carbon nano heating pipe and the hot air heater in greenhouse were 41% respectively.
        4,000원
        47.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Computational results with pseudoplastic fluid flows for fully developed non-Newtonian laminar flows have been obtained. Those consist of the product of friction factor and Modified Reynolds number and Nusselt numbers with respect to the shear rate parameter in an annular pipe. The numerical results of the product of friction factor and Reynolds numbers and the Nusselt numbers for both Newtonian region and the power law region were compared with previously published asymptotic results, respectively. In the present calculations, the product of friction factor and Newtonian Reynolds numbers for pseudoplastic fluid at power law region in annular pipe is 180% less than that for Newtonian fluid. For power law fluids with different power law flow indices, the difference of the product of friction factor and power law Reynolds number between previous and the present results at the power law region is within 0.20%. The solutions also show the effect of the shear rate parameter on the Nusselt number and about 11% increase of Nusselt number at the power region.
        4,000원
        48.
        2011.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 대상은 1-2W 기본형 온실의 기둥을 절단하여 동일한 규격의 파이프로 용접하여 온실의 측 고를 높인 온실이다. 이와 같이 개조형 온실에 풍하중이나 적설하중이 작용할 경우, 어떠한 형태로든 용 접부위에는 구조적으로 불안전 할 것으로 판단된다. 이를 검토학기 위하여 4단계에 걸쳐 용접된 기둥에 대한 굽힘 강도를 측정하여 용접하지 않은 원상태의 파이프와 비교 검토한 결과는 다음과 같다. 온실구조용 강관에 대한 용접결합부의 굽힘 시험의 경우, 하중재하 방법에 관계없이 양단 지점부위와 하중 재하부위가 하중을 견디지 못하고 함몰되는 현상을 보임으로서 합리적인 결과를 도출할 수가 없었 다. 따라서 지점 및 하중 재하부위에 내부 파이프 (봉강)을 삽입함으로서 부분적인 문제점을 보완할 수 있었지만, 보다 합리적인 굽힘 시험 방법이 고안되어야 할 것으로 판단되었다. 용접결합부의 강도는 원형 상태에 비해 별 차이를 보이지 않았고, 시료의 제작 조건에 따라 경미한 차이를 보였으나, 용접 과정에서 부실의 정도가 결정적인 강도 손실을 유발할 수 있음이 예상되었다. 용접결합과정의 문제점이나 접합 작 업 후, 기둥 부재의 기울어짐 등에 대한 문제점이 없다는 전제 하에 용접한 파이프의 강도는 일반적으로 원형상태의 강도에 비해 약 84~90% 정도로 가정함이 합리적일 것으로 판단되었다. 그리고 접합부의 녹 발생이나 기타 용접결합에 따른 중장기적 강도 저하 등을 고려할 때, 부득이한 경우가 아니라면 현재 농 가에서 시도되고 있는 온실의 주요 부재에 대한 구조변경 등은 구조안전성 측면에서 지극히 삼가 되어야 할 것으로 판단되었다.
        4,000원
        50.
        2010.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this research, the submersible fish cage was designed to avoid structural and biological damage during harsh sea conditions. The submersible cage system consists of netting, mooring ropes, a floating collar, floats, sinkers and anchors. Whole elements of the cage were modeled on the mass-spring model. The computer simulations were carried out to investigate the dynamic behavior of the cage and to calculate mooring line tension subjected to tidal currents and waves. As expected, the tension values in the mooring line of the submerged position are 36% less compared to that of the surface cage under the same loading conditions. As the wave was used in combination with the current velocity of 1m/s, the average tensile load for the submerged cage showed 85% of the value for the floating cage. The simulation results provide an improved understanding of the behaviors of the structure and valuable information on the optimized design of the cage system exposed to open ocean environmental factors.
        4,300원
        54.
        2008.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 소형 파이프하우스 설계시 구조계산에 필요한 지점조건을 구명하기 위하여 실물크기의 파이프 하우스에 환산된 적설하중 및 풍하중을 재하하여 온실의 붕괴양상과 변위 및 변형도를 측정하였으며, 측정값을 여러 가지 지점조건에 대해 구조해석한 값과 비교 분석하였다. 온실에 작용하는 적설 및 풍하중의 등분포 하중을 집중하중으로 환산할 때 환산된 집중하중의 개수별로 하중효과를 비교 분석한 결과, 적설하중의 경우 최소 2개 이상의 집중하중으로 환산하는 것이, 풍 하중의 경우 각각의 등분포된 수압면의 하중을 1개씩의 집중하중으로 환산하는 것이 등분포하중과 유사한 하중효과가 나타나는 것으로 분석되었다. 변형도의 변화를 분석한 결과 적설하중 작용시에는 예측된 바와 같이 처마부위에서 붕괴된 것으로 나타났으며, 풍하중 작용시에는 풍상측의 처마와 지점부위의 변형이 가장 크게 발생하였고 다음으로 풍하측의 처마와 곡부의 변형이 크게 발생하였으며, 가장 큰 변형을 나타낸 처마가 위험부위로 판단되었다. 응력과 변위에 따른 지점조건을 분석한 결과 지점조건에 따른 변위의 크기는 변위방향과 모델종류에 관계없이 모두 지면고정 〈지하고정〈지면힌지〈지하힌지 순으로 나타났으며, 별도의 기초 없이 서까래를 땅속에 바로 매입하여 설치하는 소형 파이프 하우스의 구조설계시 지점조건을 매입깊이에서의 지하고정으로 하는 것이 바람직할 것으로 판단 되었다.
        4,000원
        55.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 기존 비닐하우스 아연도 강관을 사용한 하우스 폭 3.6m와 5m 천창개폐형 대립계 포도 비가림하우스에 대한 구조적 안전성을 검토하고, 인장강도 400N·mm-2(SGH400 등) 이상의 파이프를 사용하는 조건에서 하우스 폭 5m인 천창개폐형 대립계 포도 비가림하우스에 대하여 구조적으로 안전한 최적 파이프 규격을 제시하고자 수행하였다. 주기둥 3m×서까래 60cm인 천창개폐형 3.6m 비가림하우스의 경우, 적설심 35cm에서는 구조적으로 안전한 것으로 분석되었으나 측면 및 전후면 풍속 35m·s-1에서는 불안전한 것으로 나타났으며, 동일 주기둥과 서까래 간격을 갖는 천창개폐형 5m 비가림하우스의 경우에는 적설심 35와 풍속 35m·s-1에서 모두 불안전하여 구조보강이 필요한 것으로 분석되었다. 그리고 동일 주기둥과 서까래간격을 가지나 인장강도 400N·mm-2 이상을 갖는 파이프를 사용하는 조건에서 천창개폐형 5m 비가림하우스의 최적 파이프 규격은 지붕높이 1.6m(아치형)와 지붕높이 1.8m(복숭아형)에 대하여 동일하게 두 경우로 규격화 할 수 있었다. 즉, 안전풍속 35m·s-1와 안전적설심 40cm에서 구조적으로 안전한 서까래 규격은 Φ31.8×1.5t@600이었으며, 안전풍속 35m·s-1와ss 안전적설심 35cm에서는 서까래 Φ25.4×1.5t@600인 것으로 분석되었다. 덕면으로부터 곡부보까지의 높이는 안전적설심보다는 안전풍속에 직접적인 영향을 미치는 것으로 분석되었으며, 처마를 높임에 따라 측면풍속에 대해서는 방풍벽파이프(측벽서까래)를, 전후면 풍속에 대해서는 마구리기둥의 규격을 강화하여야 하는 것으로 분석되었다.
        4,000원
        56.
        2007.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 극한 해상상태나 돌발적인 환경하중에서 양광시스템의 진수와 인양이 이루어질 때 발생할 수 있는 파이프의 점핑현상과 이에 의해 유발되는 파이프의 장력변화 및 위해도를 위한 해석기법을 제시하였다. 동적 과도응답 해석은 본 논문에서 제시된 기법에 의하여 여러 가지 형식의 임펄스에 대해 수행되어졌으며, 해석을 위한 모델로 KT-Submarine에서 사용하고 있는 '세계로호' 양광시스템의 진수, 인양 시스템을 선정하였다. 결과적으로 양광시스템관련 해상작업을 위한 지침이 제시되었다. 정성적인 해석기법의 검증과 비교를 위하여 ROV진수 시 발생 가능한 케이블장력 과도응답을 해석하였으며 이를 통하여, 본 연구에서 시도한 수학적 모델링과 이상화된 임펄스에 대한 파이프의 과도 응답과정이 충분한 정성적인 기초자료를 제공해 줄 수 있다는 점을 파악하였다.
        4,000원
        1 2 3 4 5