Purpose : To evaluate changes and correlations of ACA, ACD and ACV by ages and refractive errors using Pentacam in Korean undergraduate students and elderly people. Methods : 52 healthy eyes(male : 27, female : 25) of undergraduate students and 38 healthy eyes of elderly people were recruited(average age : 22.52148±0.62435 years). We measured anterior chamber angle(ACA), anterior chamber depth(ACD), anterior chamber volume using Pentacam(Oculus Co.) and spherical equivalent refractive errors(SE) by subjective re(raction. 52 undergraduate students were classified into emmetropes group(-0.75-+0.750) and myopes group(> -1.000). The averages SE of emmetropes and myopes groups were -0.28333±0.32550 and -3.12162±1.51110 respectively. Results : The average ACD. ACA and ACV were 3.18906±0.20435 mm, 40.53019± 5.10831°, 193.49057±28.45213 mm3 respectively in undergraduate students group and 2.76158±0.42819 mm. 32.63947±5.84385°. 134.21053±28.94091 mm respectively in elderly group. lncreasing age was associate with reduced ACA. ACD and ACV. and there was no correlation by sex. There showed significant differences between ACD and ACA(t = - 47.64. p = 0.00). between ACO and ACV(t = -38.78. p = 0.00) and between ACV and ACA(t = 39.48. p = 0.00) l = - 50.61 p = 0.00. t = - 49.27 p = 0.00. t = 38.81 p = 0.00 respectively in undergraduate students group and t = -31.43 p = 0.00. t = -28.00 p = 0.00. t = 21.20 p = 0.00 respectively in elderl y group. Excellent correlation was found between ACD and ACV in undergraduate students group(R = 0.89). There showed significant differences in ACO and ACV(t = -2.25 p = 0.03. t = -2.24, p = 0.29 respectively), however no significant difference in ACA(t = -1.59 p = 0.12) between emmetopes group and myopes group. Conclusion : lncreasing age was associate with reduced ACA. ACO and ACV ; ACA was changed from grade 4 to grade 3 by Shaffer's classification. There showed significant differences between ACD and ACV. between ACD and ACA, between ACV and ACA Especially excellent correlation was found between ACD and ACV in undergraduate students group(R = 0.89). There showed significant differences in ACO and ACV, however no significant difference in ACA between emmetropes group and myopes group.
실제 사용시 신뢰성을 보장하기 위하여, 고온에서 장시간 동안의 시효로 인한 ACA COG(Anisotropic Conductive Chip On Glass) 접합 특성의 변화가 연구되었다. 모든 접합 시편들은 160˚C에서 156시간 동안 유지되었고 시효하는 동안의 접촉저항의 변화는 감소하였다. 특히, 156시간이후, 4000개 /mm2의 입자밀도를 가진 ACA에서는 접촉저항의 벼노하가 나타나지 않았다. 입자크기의 경우 작은 입자를 가진 ACA는 160˚C에서 시효후에도 접촉저항의 변화를 보이지 않았다. 또한 4000개/mm2 및 5μm 입자를 가진 ACA를 사용한 시편은 접합상태가 안정하였기 때문에 160˚C에서도 경화수지의 팽창 및 리플로우(reflow)에 의한 영향을 받지 않았다. 따라서 이 ACA에서는 160˚C에서 156시간 동안 시효한 후에도 오픈(open)이 나타나지 않았다.
구동 IC를 유리기판 위의 Al패드 전극에 연결하는 LCD(Liquid Crystal Display) 모듈을 실장하는 Chip On Glass (COG) 기술을 개발하기 위하여 기존에 잘 알려진 기술 가운데 실제로 적용 가능성이 가장 유망한 이방성 도전 접착제 (ACA, Anisotropic Conductive Adhesives)를 사용한 공정에 대하여 조사하였다. ACA 공정은 본딩 부분에 ACA 수지를 균일하게 분포시키는 공정과 자외선을 조사하여 수지를 경화하여 칩을 실장하는 공정의 2단계로 진행하였다. 칩에 가해준 하중은 2-15kg이었고 칩의 예열 온도는 120˚C이었다. 이방성 도전체는 Au 또는 Ni이 표면 피막 재료로 사용된 것을 사웅하였으며 전도성 입자의 갯수가 500, 1000, 2000, 4000개/mm2이며 크기가 5, 7, 12μm이었다. ACA 처리의 결과 입자 크기가 5μm이고 입자 밀도는 4000개/mm2일 경우가 대단히 낮은 접촉 저항 및 가장 안정된 본딩 특성을 나타냈었다.