검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 148

        41.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the homogeneity and stability of standard samples for proficiency testing in indoor air quality within the country (formaldehyde, benzene, toluene, ethylbenzene, p-xylene, styrene, TVOC) were evaluated. The procedures and statistical analysis methods applied in ISO/IEC 13528 (2009) and KS A ISO Guide 35 (2005) were applied as evaluation methods. The homogeneity evaluation was a statistical analysis of repeated measurements of each of the 11 ports and between the 11 ports concentration data. As a result, the coefficient of variation (CV) was within the range of 1.9%~5.9%. The difference between the ports was found to be insignificant and met the statistical standard specified in KS Q ISO 13528. The stability evaluation was assessed by the change in concentration over the long-term stability of the standard samples stored for 90 days. The coefficient of variation (CV), which was within the range of 2.6%~9.0%, exhibited changes in the concentration of the long-term stored standard samples. However, the results satisfy the statistical standard specified in KS A ISO Guide 35. Overall, there is no significant difference between the homogeneity of the standard samples by the port and the stability of the long-term stored samples. Therefore, it is considered to be an appropriate method to supply standard samples in an indoor air quality proficiency test.
        4,000원
        42.
        2017.10 구독 인증기관·개인회원 무료
        As a result of the increasingly serious air pollution worldwide, there are many social costs in the country. In general, there are legal measures to improve air quality such as investment projects, input of public funds, attraction of private capital, and regulation of air pollution prevention. In this study, we propose future legislative policies through the following analysis on the status of various researches in domestic and foreign countries for the improvement of air quality and related legal system. The domestic indoor air quality is getting better through ongoing management. From a legal perspective, The air quality law, such as indoor air quality law and environmental law, has been continuously revised to improve indoor air quality. However, contrary to the air quality law, indoor air quality management is carried out by various related departments under current law. Due to the different management facilities and management standards of each ministry, the effectiveness of relevant laws is deteriorated in organically managing multi-use facilities. This may lead to confusion and may be an impediment to the effective achievement of the institution's objectives. The pollutants of interior space are one of the main causes not only building materials, but also office equipment such as computers. however, The pollutants to be managed under the current legislation are mainly limited to building materials. In addition, the criteria set for each pollutant have a problem that it depends on the after-regulation standard that is made after the pollutant is released from the pollutant source. There is a need for systematic analysis and research to prevent adverse effects that may occur due to pollution sources through the prevention system. It is time to change the direction of regulation-oriented policies and to make policy changes that can improve air quality through systems such as emission trading system..
        43.
        2017.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        While the air quality of public facilities such as daycare centers is managed by law, the management of air quality in residential buildings is not mandatory. For this reason, air quality in an apartments has not been well surveyed. In this study, we investigated the influence of cooking and ventilation on the indoor air quality in an apartment. Continuous measurements were performed using real-time monitoring instruments from June 9 to 17, 2014 in Seoul, Korea. A CO2 meter was used to measure CO2 concentration and temperature. A portable aerosol spectrometer (0.25-32 μm), a nanoparticle aerosol monitor (10-1,000 nm), and an aethalometer (total suspended particulate, black carbon) were also used. During the measurement period, ventilation and cooking activities were observed 8 and 10 times, respectively. In 5 of the observed cases, both activities were done simultaneously. During the ventilation, CO2 concentration and temperature were decreased; however, particle concentrations were increased. When cooking was done, particle concentration was increased in some cases; however, CO2 concentration and temperature were unchanged. Combined cased CO2 concentration and temperature were decreased and particle concentrations were increased.
        4,300원
        44.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was carried out to explore possibilities of cultivating horticultural crops in the air-dome greenhouse in comparison to the common iron-frame greenhouse as the standard. The levels of carbon dioxide and atmospheric pressure measured inside the air-dome greenhouse turned out to be higher than those measured inside the iron-frame greenhouse. Contrastingly, light intensity was relatively weaker inside the air-dome greenhouse due to the air-inflated double layers. Plants of melon and cherry tomato were cultivated from May 2 to August 12, 2016, respectively in the two greenhouses. For melon plants, growth in the air-dome greenhouse effectively increased fruit weight as well as trunk circumference compared to iron-frame greenhouse. Moreover, soluble sugar content of melon fruit was significantly higher when cultivated in the air-dome greenhouse. For cherry tomato plants, fruit yield of cherry tomato was significantly increased inside the air-dome greenhouse. Furthermore, it has been found that the air-dome greenhouse was considerably effective in shortening the growing period of melon and cherry tomato plants in comparison to the iron-frame greenhouse.
        4,000원
        45.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the distribution of each facility group, the pollution level of local municipalities and the status of self-measurement were investigated and analyzed using data provided by the Ministry of Environment. It was found that most of the workplaces to be managed are facilities of sensitive class, indoor parking lots and largescale stores. The results of the survey on the total pollution level by facility group showed that the rate of contamination was the highest in the facilities where there are many sensitive users, including the subway station and the underground shopping malls. Through self-measurement, in the case of fine particle matter, it was found that it was present in amounts of 51.71 μg/m3, 50.72 μg/m3, 44.47 μg/m3 and 54.44 μg/m3 in medical institutions, day care centers, elderly care facilities and postnatal care centers, respectively. Also, there were facilities exceeding the standard in the medical institutions. However, most of the pollutants in the facilities surveyed by the municipality are higher than the self-measured concentrations, so it is necessary to examine the cause of such pollution.
        4,000원
        46.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The number of children who use day-care centers is increasing. Most indoor air quality (IAQ) management has been based on daily average pollutant concentrations measured once a year. A more comprehensive management of IAQ is needed to protect children’s health from air pollutants in day-care centers. In this study, we investigated the weekly variation of air pollutant concentrations in a nursing room of a day-care center located at the roadside for a week in June of 2014. Average concentrations of CO2, PM10, black carbon, and total surface area of lungdeposited particles during nursing time of the day-care center were 510 ppm, 27.8 μg/m3, 1.87 μg/m3, and 30.6 μm2/cm3, respectively, with a similar diurnal pattern shown on weekdays.
        4,000원
        47.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        시설재배 멜론은 소득이 비교적 높고 시설 내 환경 변화에 민감한 작목이다. 특히 여름 고온기재배 시에는 광합성 저하와 호흡 증가로 인해 멜론의 생산성과 품질이 저조하다. 고품질 멜론 생산을 위해서 는 시설 내 기온과 습도를 적정 조절하는 것이 매우 중요하다. 본 연구는 고온기 멜론재배 시에 포그 및 공기유동팬을 이용한 온도와 습도 조절이 과실 품질에 미치는 효과를 구명하고자 하였다. 그 결과, 포그와 유동팬을 가동 할 때 시설 내 기온은 최대 7℃, 평균 3.2℃ 강하되었고 상대습도는 최대 28%, 평균 12% 상승하였다. 이러한 온도와 습도 조건의 영향으로 무처리(천창과 측창환기 실시)에 비하여 멜 론의 과중이 300g, 당도가 1.5°Bx 각각 높았다.
        4,000원
        48.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we investigated the effects of pre-soaking in salt and sugar solution prior to air drying at 50℃ on the characteristics of dried apples. Pre-soaking solutions included single solutions of salt 2% and sugar 2%; and combined solutions of salt 2%+sugar 2% and salt 2%+sugar 5%, respectively. The effects of pre-soaking condition and drying were evaluated in terms of moisture content (MC), water activity, color, antioxidant activity determined by DPPH radical scavenging activity, shear force, microbial contents, and sensory evaluation of apple slices. The control sample without pre-soaking showed the most rapid drying rate; in addition, the single solutions showed higher MC and water activity after drying time of 120 min, as compared to combined solutions. In all samples, MC and water activity showed high correlation coefficients of 0.91 to 0.97; whereas, shear force was negatively correlated with MC and water activity. The single solution of salt 2% showed decrease in change of color, including L, a, and b values, and the number of aerobic bacteria during drying. In addition, highest antioxidant activity and values of sensory preferences were observed in the dried apple pre-soaked in single solution of salt 2%.
        4,000원
        49.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper is focused on an economic analysis of applied air pollutant control technologies used for the particulate matters present in subway. Beneficial effects such as reduction in medical expenses and prevention of productivity loss and death are achievable through the adaptation of control technologies. The result showed that the total investment expense was 97.6 billion won and the cost-benefit was 4776.8 billion won, therefore a 4.8 benefit/ cost ratio was attained.
        4,000원
        50.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Environmental tobacco smoke (ETS) contains a large variety of substances, of which at least 50 are known to or are believed to be carcinogenic. Although the Ministry of Health and Welfare has started to prevent public exposure to ETS by enacting indoor smoking bans, some facilities still allow their customers or users to smoke indoors. In this study, indoor air quality in a pub was investigated by monitoring particulate matters (PM1.0 and PM2.5), heavy metals (As, Cd, Cr, Pb) and nicotine concentration to figure out the influence force of smoking behavior on indoor air quality. Smoking behaviors are revealed to be a major contributor the contamination of indoor air in pubs. The range of PM2.5 mass concentrations were 82.2~208.0 μg/m3 and the mean concentration of PM2.5 was 135.9 μg/m3. In the case of nicotine, the mean concentration was 12.2 μg/m3 with a range from 2.7 to 24.1 μg/m3. In the results of metal analysis, the levels of heavy metals in particulate matters in a pub were found to be much higher than those of the other public facilities.
        4,000원
        51.
        2015.12 구독 인증기관 무료, 개인회원 유료
        The spatial resolution of 3-Dimensional numerical model has a very important influence on the model result. The land-use and orographic effect is also influenced by the spatial resolution of the model. A large errors in model performance are produced depending on the terrain complexity. In this study we performed Air Quality Forecast model (AQF) simulation and analyzed the change in the ozone concentration depending on spatial resolution at small and medium-sized mixed areas with urban and rural area types. As the result, improving the spatial resolution improved the simulation of the downward trend of ozone at night. This was mainly due to improvement of local concentration contaminants at fragmented grid. In the case of wind speed, the model with high-resolution shows better agreement with observation at night.
        4,000원
        52.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to evaluate the quality of indoor air and health-related parameters (allergic rhinoconjunctivitis) of subject of study (control group and sensitive group) in two schools. The schools were categorized into two groups of newly-built school and the school older than 5 years. Removal of indoor pollutant was investigated according to volume rates (0%, 1.5%, 3%) of indoor plants inside 3 classrooms respectively. The chemicals of indoor environmental research were PM10, Volatile organic compounds (toluene and benzene), formaldehyde, temperature and humidity. ARIA (Allergic rhinitis impacts on Asthma) test was used to assess health effect for 151 students. Also, The variation of SBS symptoms for students in classroom was measured by intervention. With increasing volume ratio of classrooms, there were positive and significant results between the indoor pollutant and student's health score. Students showed improvement health score during the period of putting indoor plants, which was facilitated by the placement of indoor plants at newly-built school classroom of indoor plants volume ratio 3%. From the results above, it could be tentatively effective newly-built school classroom of indoor plants volume ratio 3% improve indoor air quality and student's health score.
        4,000원
        53.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 꽁치를 냉풍건조방법으로 생산한 과메기 의 성분 변화와 세척수 처리에 따른 미생물 제어효과를 조사하였다. 건조를 하기 전 시료의 수분 함량은 56.62% 였으나 초기 수분 함량이 급격히 감소하다가 시간이 지날 수록 완만해지는 결과를 보였다. 건조 처리 전의 과메기의 색도차는 42.40이었으나 온도와 건조시간이 증가함에 따라 색도차의 값이 감소하였다. 건조를 하지 않은 대조 구의 TBA 값은 0.219였고, 모든 온도 조건에서 건조가 진행될수록 산패도가 증가하였다. 과메기의 구성아미노산을 분석한 결과, 25℃에서 36시간을 건조시킨 처리구에서 총 아미노산 함량이 가장 높았으며 40℃에서 12시간을 건조 시킨 처리구가 총 아미노산 함량이 가장 낮았다. 건조온도와 시간에 따른 과메기의 지방산 분석 결과, 주요 지방 산은 14:0, 16:0, 18:1 등이 각각 18.15~20.96%, 28.06~ 32.51%, 17.06~19.81%로 분포하였다. Chlorine dioxide 100 ppm에서 60초 동안 세척한 구에서 미생물제어 효과가 가장 우수하였으며 과메기의 위해미생물 동정한 결과, Pseudomonas sp.와 Pseudomonas putida 로 두 균주가 조사되었다.
        4,000원
        54.
        2015.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 휘발성 유기화합물(VOC)과 먼지(PM)의 배출원 프로파일로부터 화학종 분류를 할당하고, 성김 행렬 조작자 핵심 배출량 시스템(SMOKE) 내에 배출원 분류코드에 따른 배출원 프로파일의 화학종 분류와 시간분배계수를 수정하는 것이다. 기솔린, 디젤 증기, 도장, 세탁, LPG 등과 같은 VOC 배출원 프로파일로부터 화학 종 분류는 탄소 결합 IV (CBIV) 화학 메커니즘과 주 규모 대기오염연구센터 99 (SAPRC99) 화학 메커니즘을 위해 각각 12종과 34종을 포함한다. 또한 토양, 도로먼지, 가솔린, 디젤차, 산업기원, 도시 소각장, 탄 연소 발전소, 생체 연소, 해안 등과 같은 PM2.5 배출원 프로파일로부터 화학종 분류는 미세 먼지, 유기탄소, 원소 탄소, 질산염과 황산염의 5종으로 할당하였다. 게다가 점 및 선 배출원의 시간 프로파일은 2007년 수도권 지역에서의 굴뚝 원격감시시스템(TMS)과 시간별 교통 흐름 자료로부터 구하였다. 특별히 점 배출원에 있어 오존 모델링을 위한 시간분배계수는 굴뚝 원격감시시스템 자료의 NOX 배출량 인벤토리에 근거하여 추정하였다.
        4,800원
        55.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We studied the changes in the concentration of total volatile organic compounds generated in newly-built schools (five kindergarten schools, two primary schools, three middle schools, one high school) by the bake-out. Samples were collected in classrooms. By using the bake-out technique the removal efficiency of total volatile organic compounds was 89.1%(maximum) and 27.5%(minimum). By using this bake-out technique the removal efficiency was 42.5% greater than the ventilation method. Therefore, we determined that it is appropriate to apply both the bake-out and ventilation methods in the case of newly-built schools
        4,000원
        56.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Hazardous air pollutants such as NO2, VOCs and PM10 were measured Daegu, Korea in major micro-environments,where housewives spend the most of their time, and personal exposure times were estimated by using time activitypatterns and exposure scenarios. The major microenvironments of housewives were selected using the ‘Time-UseSurvey’ conducted by the National Statistical Office in Korea in 2009. A total of 4,514 (weekdays) and 3,063(weekends) housewives were recruited for the ‘Time-Use Survey.’ It seems that housewives are spending about80% of their time in the house, and about 5% of their time outdoors during weekdays and weekends. The indoor/outdoor ratio of the average concentration of NO2 was more than 1, which indicated that the source was indoors.Toluene was shown to have higher concentrations indoors than outdoors. Ethylbenzene and xylene displayedsimilar characteristics to toluene, and the concentration ratio for indoor/outdoor was shown to be 1.29 ± 0.76 and1.04 ± 0.45, respectively, higher concentrations indoors. Based on the results of the time activity patterns ofparticipants, 3 kinds of exposure scenarios were formulated. The spent time and air concentration in eachenvironment were assumed as normal and lognormal distribution, respectively. And then the Monte-Carlosimulation was conducted. According to the result of the simulation, the exposures to hazardous air pollutantsrevealed an increasing pattern as housewives visits other indoor environments such as supermarkets.
        4,000원
        57.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to evaluate the quality of indoor air due to the remodeling and newly-built in S City, 60 schools wereinvestigated in formaldehyde (HCHO) and total volatile organic compounds (TVOCs). One school exceeded thenational standard of formaldehyde 100µg/m³ at 1st measurement. Thirty-eight schools showed higher level ofTVOCs over 400µg/m³ at 1st measurement. Twelve schools showed higher level of TVOCs over 400µg/m³ at2nd measurement. This result derived from TVOCs which originated from the building materials and finishingmaterials. To prevent the pollution of indoor air quality at schools caused by formaldehyde and TVOCs, therecommendation of environmentally-friendly building materials, the diminishment of emission by bakeout process,the efficient combination of natural ventilation and mechanical ventilation, and antibacterial effect of chemicalcontrol measures as photo-catalysts should be given positive investigation.
        4,000원
        58.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Air compressor is an important facility with electric power in the industry. However, because of the noise and vibration of air compressor and is installed outside the building management difficulty. In this study, MCP (Micro Control Processor) to remote monitoring of the air compressor via the compressed air through improved quality and allows stable maintenance were designed. So, increase the productivity improvement of energy-saving effect can be obtained. Remote real-time information stored on your PC to manage air compressor equipment was higher reliability. Monitoring system is developed in this study was applied to embedded systems. It is easy to install air compressor, and low maintenance costs was to raise the economic impact.
        4,000원
        59.
        2013.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The objective of this study is to investigate the capability of the combined model of traffic simulation, emission and air dispersion models on the impact analysis of air quality of mobile sources such as vehicles. METHODS : The improvement of the quality of life brings about the increasing interest of the public environment. Many endeavors including the travel demand management, the application of the state-of-the-art ITS technologies, the promotion of eco-friendly vehicles have been tried in transportation area to reduce the modal emissions. Especially, it is expected that the increasing number of eco-friendly vehicles in the road network would be able to reduce the pipe-tail emissions tremendously. From this perspective, we have performed a study on the impact analysis of the popularization of the eco-friendly vehicle in the place of the fossil fuel energy powered vehicles on the surrounding air quality using the combined framework of microscopic traffic simulation, emission and air dispersion model. RESULTS : The combined model successfully captured the effect of moving to the eco-friendly vehicles on the air quality, and the results showed that the increasing usage of eco-friendly vehicles can improve the surrounding air quality tremendously and that the air dispersion model plays a crucial role in the investigation of the air quality change around the main corridor. CONCLUSIONS : This study demonstrated the capability of the combined model showing the spatio-tempral change of emission concentration.
        4,000원
        60.
        2013.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study was performed to investigate the distribution of indoor air pollutants in medical facility in Gyeonggi-do area from February to November, 2012, and to conduct the health risk assessment from obtained data. PM10, CO₂, formaldehyde, CO, and total bacteria count(TBC) did not exceed the maintained standards, but mean concentration of TVOC was 402.3 ㎍/㎥ and thirteen of them exceeded the recommended standard. In the concentration distribution of pollutants for the monthly samples, CO₂, formaldehyde, TVOC, TBC were the highest level in August. From the factor analysis of indoor air pollution provided three factors; the first factor was seasonal factor (indoor temperature and humidity, TBC and formaldehyde), the second factor was ventilation factor (CO₂, PM10 and CO), and the third factor was building(or interior) factor (TVOCs). In the health risk assessment results, the excess carcinogenesis of formaldehyde for resonable maximum exposure worker was 1.21×10-⁴ which means exceeding the cancer criteria(1.0×10-⁴). We confirmed the probability of health effect caused by TVOC. The lifetime excess cancer risk of carcinogens(benzene, formaldehyde) and hazard quotient of non-carcinogens(toluene, ethylbenzene, xylene, styrene), and risk of regulation substances(PM10, CO₂) were safety level for inpatients and out patients.
        4,600원
        1 2 3 4 5