검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2024.03 KCI 등재 구독 인증기관·개인회원 무료
        The present study was carried out to investigate the concentration and species diversity of airborne fungi in thermophilic mushroom cultivation houses. Fungal concentration measurements were performed in April and May 2022 for a Pleurotus ostreatus cultivation house, in July and August 2023 for a Pleurotus sajor-caju and Agaricus blazei cultivation house, and in June, July and August 2023 for a Pleurotus pulmonarius, Pleurotus sajor-caju and Calocybe indica cultivation house. The airborne fungal concentration was 2.95 × 102 CFU/m3~105CFU/m3, above 105CFU/m3, and 1.12 × 103 CFU/m3~ 9.17 × 103 CFU/m3 in the three cultivation houses, respectively. A total of 8 genera and 22 species of airborne fungi were isolated from three mushroom cultivation houses. 5 genera and 7 species were identified from P. ostreatus cultivation house. Furthermore, 4 genera 6 species were found from A. blazei and C. indica cultivation house. In addition, 5 genera and15 species were isolated from P. pulmonarius, P. sajor-caju and C. indica cultivation house. Among the fungi isolated, the class of Eurotiomycetes was the most common. Among the 22 fungal species, Aspergillus flavus, A. ochraceus A. sydowii, A. tubingensis, A. westerdijkiae, Penicillium brevicompactum, P. citrinum, and P. steckii have been reported as harmful species to mushrooms, food, and human.
        2.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Mold is one of the harmful biological pollutants in the indoor environment. To investigate how the contamination degree of mold existing in the indoor environment differs according to the characteristics of the house, the concentration of mold in the indoor air was investigated for the houses damaged by leakage or flooding. As a result of a survey of 20 houses located in Gyeonggi-do and Chungcheong-do, the concentration of mold in indoor air surprisingly exceeded more than two times the recommended indoor air quality standard of 500 CFU/m3 in all the houses investigated. The fungal concentration was high in houses with condensation and mold odors. As for the housing type, the pollution degree was higher in detached houses than in row houses. As for the type of water damage, mold contamination was higher in the leaky houses than in the flooded houses. The degree of mold concentration was 1,237 CFU/ m3 in the leaky houses. In terms of housing age, pollution was very high in houses over 20 years old. The occurrence of these measured mold concentrations was correlated at a significant level with respect to the properties of the house. This study shows that in the case of water damaged houses, careful management of mold contamination is required.
        4,000원