        1.
        2017.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a energy recovery ventilation system was applied to the pig model, intake and exhaust duct were installed at a height of top(2.1 m), middle(1.25 m) and bottom(0.4 m). In each of the 9 test sites, one test was performed from 10:00 to 18:00, optimal temperature exchange efficiency and temperature distribution were analyzed. In order to analyze the effect of the energy recovery ventilation system, the temperature of 31 points(4 points of the ventilation system and 27 points in the pig house model) was measured from 10:00 to 18:00. The test that showed the highest heat exchange efficiency was the configuration of middle intake duct and top exhaust duct, which was 75.44%. The test that showed the most uniform distribution was the configuration of middle intake duct and bottom exhaust duct. These results will be utilized to optimally design feeding environment of actual pig houses and to reduce fuel cost.
        4,000원
        2.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 무창돈사에서 폐기되는 에너지를 재이용하기 위해 열회수형 환기장치의 효율 및 돈사 내부 환경에 미치는 영향을 분석하여, 실제돈사에 적용 가능성을 구명하고자 한다. 이를 위해 열회수형 환기장치의 적용에 따른 내부 온도, 상대습도, CO2 및 부유미생물을 측정, 분석하여 돈사 내 열회수형 환기장치 적용 시 연료비 절감 및 돼지 사육 환경의 최적 조건 산출을 위한 기초자료로 활용하고자 한다. 실험은 돈사 내 환기팬 및 열회수형 환기장치를 설치하여 세 가지 다른 조건에서 실험을 행하였다. 첫 번째, 환기팬 및 열회수형 환기장치를 가동하지 않은 상황(Test-1), 두 번째, 환기팬만 가동한 상황(Test-2), 그리고 마지막으로 열회수형 환기장치만 가동한 상황(Test-3), 세 가지 상황으로 구분하여 실시하였다. 열회수형 환기장치를 가동하였을 경우, 내부 상, 중, 하층부의 온도가 가장 균일한 것으로 나타났고, 상대습도 또한 일정하게 유지되는 것으로 나타났다. CO2 농도의 경우, 환기팬을 가동한 상황(Test-2)보다 다소 높았지만 시간이 지남에 따라 농도가 낮아지는 것으로 보아, 환기에 효과가 있다고 판단된다. 부유미생물의 경우는 밀폐된 상황(Test-1) 보다 오히려 높게 측정되었는데, 이는 열회수형 환기장치의 내부 교차오염 등에 의한 것으로 판단된다.
        4,500원