검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 105

        101.
        2003.04 KCI 등재 서비스 종료(열람 제한)
        Pesticides were extracted from samples with 70% acetone and methylene chloride in order, and then cleaned up via open-column chromatography apparatus packed with florisil, and finally analyzed simultaneously the organochlorine and pyrethroid pesticides using GC(ECD). An ultra-2 fused silica capillary column was used to separate and identify the products. The resolution between the last isomeric peak of cypermethrin(59.987min) and the first isomeric peak of flucythrinate(60.043min) was not satisfactory. The last isomeric peak of fenvalerate(62.344min) and the first isomeric peak of fluvalinate(62.397min) were overlapped. Recoveries of soybean sample for the most pesticides were 73.3% to 102.4%. Detection limits were between 0.004 and 0.063㎍/㎎ when this method was used.
        102.
        2003.01 KCI 등재 서비스 종료(열람 제한)
        The study was carried out to evaluate the new analytical method of phthalate esters(diethylphthalate, di-n -butylphthalate, butylbenzylphthalate, bis(2-ethylhexyl)phthalate), one of the endocrine disruptors, which were performed by GC/MS-SIM(selected ion monitoring). The phthalate esters were extracted from water samples using solid-phase extraction on C18 columns. It investigated that the extraction recovery rate of phthalate esters with different solvents and solvent volume. The optimal solvent was dichloromethane and proper volume of dichloromethane for recovery of phthalate esters was 4 mL. There were good linearities(above R2=0.9975) in the range 0.01~0.50㎎/L, and the detection limits were below 0.01~0.03㎍/L. The recovery rates, RSD and MDLs for phthalate esters were 80~114%, 5.0~8.1% and 0.03~0.11㎍/L, respectively. This method shows a good precision of phthalate esters.
        104.
        1997.04 KCI 등재 서비스 종료(열람 제한)
        Organophosphate pesticides were extracted with 70% acetone and then transferred to dichloromethane. Extracts were applied to open-column chromatography with florisil The final extract was analyzed by gas chromatography with nitrogen-phosphorus detector(GC/NPD). Recoveries of the 18 organophosphate pesticides were ranged from 88.7% to 100.0% for the narrow-bore capillary GC(Ultra-2). The minimum detectable level of this analytical method was 0.019 - 0.035 ㎎/㎏. Sample throughput(extraction, open-column chromatography, and GC analysis) was decreased considerably (8h per sample).
        105.
        1996.10 KCI 등재 서비스 종료(열람 제한)
        A method for the simultaneous analysis of 31 residual organic chloride pesticides was studied using gas chromatography. Prepared analytical samples were injected to gas chromatography (HP 5890 Series II plus) on the Ultra-2 column with ECD. The packing materials for column were changed as the following reagents ; florisil and alumina N. The residual solution was loaded to column and was eluted with elution solvents ; ether : benzene (2 : 8) solution, hexane : benzene (1:1) solution, dichloromethane, acetone, and methanol. The analytical results showed that 6 kinds of organic chlorides were not detected when florisil (first condition) was used as the column packing material. The nondetected 6 kinds of organic chlorides in the first analytical condition were detected and the recoveries of thrin-pesticides were increased, in particular, captan and captafol, but the recoveries of benzene hexachloride compounds were decreased when dichloromethane and methanol were added as elution solvents (packing material was florisil as in the first condition). The recoveries of dichlorfluanid, chlorofenvinfos, folpet, and dicofol were increased and that of aldrin was increased, but those of captan and captafol were not good when alumina N was used as the packing material. To detect simultaneously thrin-pesticides, captan, and captafol, florisil and alumina N were used as the packing materials. The elution result showed that captan and captafol were not detected. This was because the column was activated insufficiently. The analytical method was the best (31 kinds of organic chlorides in the residual pesticides were detected sharply and showed high sensitivity) when the column (packing materials were florisil and alumina N, together) was fully activated and the impurities were removed using various elution solvents.
        6