검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 23

        1.
        2023.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        YAG phosphor powders were fabricated by the atmospheric plasma spraying method with the spray-dried spherical YAG precursor. The YAG precursor slurry for the spray drying process was prepared by the PVA solution chemical processing utilizing a domestic easy-sintered aluminum oxide (Al2O3) powder as a seed. The homogenous and viscous slurry resulted in dense granules, not hollow or porous particles. The synthesized phosphor powders demonstrated a stable YAG phase, and excellent fluorescence properties of approximately 115% compared with commercial YAG:Ce3+ powder. The microstructure of the phosphor powder had a perfect spherical shape and an average particle s ize of a pprox imately 30 μm. As a r esult of t he PKG t est of t he YAG p hosphor p owder, t he s ynthesized phosphor powders exhibited an outstanding luminous intensity, and a peak wavelength was observed at 531 nm.
        4,000원
        2.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        실버 페이스트는 상대적으로 낮은 열처리로 공정이 가능하기 때문에 전자 소자 응용분야에서 유용한 전극 재료이다. 본 연구에서는 은 페이스트 전극에 대기압 플라즈마 제트를 이용하여 전극 표면을 처리 했다. 이 플라즈마 제트는 11.5 kHz 작동 주파수에서 5.5 ~ 6.5 kV의 고전압을 사용하여 아르곤 분 위기에서 생성되었다. 플라즈마 제트는 대기압에서 수행함으로써 인쇄 공정에 더 유용할 수 있다. 플라즈 마 처리시간, 인가된 전압, 가스유량에 따라 전극의 표면은 빠르게 친수성화 되었으며 접촉각의 변화가 관 찰되었다. 또한, 대면적 샘플에서 플라즈마 처리 후 접촉각의 편차가 없었는데, 이는 기판의 크기에 관계없 이 균일한 결과를 얻을 수 있었다는 것을 의미한다. 본 연구의 결과는 대면적 전자소자의 제조 및 향후 응 용 분야에서 적층 구조를 형성하는데 매우 유용할 것으로 기대된다.
        4,000원
        3.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The effects of different spray angles (90°, 85°, 80°) on the microstructure and mechanical properties of a Y2O3 coating layer prepared using the atmospheric plasma spray (APS) process were studied. The powders employed in this study had a spherical shape and included a cubic Y2O3 phase. The APS coating layer exhibited the same phase as the powders. Thickness values of the coating layers were 90°: 203.7 ± 8.5 μm, 85°: 196.4 ± 9.6 μm, and 80°: 208.8 ± 10.2 μm, and it was confirmed that the effect of the spray angle on the thickness was insignificant. The porosities were measured as 90°: 3.9 ± 0.85%, 85°: 11.4 ± 2.3%, and 80°: 12.7 ± 0.5%, and the surface roughness values were 90°: 5.9 ± 0.3 μm, 85°: 8.5 ± 1.1 μm, and 80°: 8.5 ± 0.4 μm. As the spray angle decreased, the porosity increased, but the surface roughness did not show a significant difference. Vickers hardness measurements revealed values of 90°: 369.2 ± 22.3, 85°: 315.8 ± 31.4, and 80°: 267.1 ± 45.1 HV. It was found that under the condition of a 90° angle with the lowest porosity exhibited the best hardness value. Based on the aforementioned results, an improved method for the APS Y2O3 coating layer was also discussed.
        4,000원
        5.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 저온살균(60oC, 5-20분)과 대기압플라즈마(5- 20분)를 병용한 고춧가루 중의 E. coli 저감화 및 시너지 효과를 조사하였다. 저온살균 단일처리시 대장균의 불활 성화는 최대 2 log10 CFU/g(=99% 감소) 이상 나타내었으며, 대기압플라즈마 5, 10, 15, 및 20분간 단일처리 하였을 때 각각 0.4, 0.8, 0.9 및 1.4 log10 CFU/g 감소되었다. 저온 살균 및 대기압플라즈마 단독 처리만으로는 만족할 만한 미생물 저감화효과를 얻을 수 없었기에 저온살균 처리 후, 대기압플라즈마를 병용처리 하여 대장균의 불활성화는 1- 6 log10 CFU/g 이상 감소되었다. 그러나, 저온살균과 대기 압플라즈마 병용처리에 따른 관능적 품질 (색, 이취, 맛, 조 직감 및 전체적인 기호도)에 대한 유의적인 차이는 관찰 되지 않았다(P>0.05). 따라서 고춧가루의 미생물학적 안전성 확보를 위해 저온살균과 대기압플라즈마 단독처리보다 이 둘의 병용처리가 E. coli의 확실한 저감화 효과를 유도 하고 식품 고유의 품질특성을 유지하는데 효과적이었음을 본 연구를 통해 확인되었다.
        4,000원
        6.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to investigate the quality properties of sausages added with the atmospheric pressure plasma treated extract of Perilla frutescens Britton var. acuta Kudo (red perilla). The lyophilized powder of red perilla extract treated by atmospheric-pressure plasma contained 7.5 g kg-1 nitrite. Sausage samples were manufactured with the addition of sodium nitrite (Control), celery powder (Celery), or plasma-treated extract of red perilla (PTP) to obtain nitrite concentration of 70 mg kg-1. The residual nitrite content was the lowest in PTP during storage for 21 days at 4℃ (p<0.05). The total aerobic bacteria counts were higher in PTP than in Control and Celery during storage at 4℃ (p<0.05). Malondialdehyde content of sausages was significantly lower in PTP than in Control and Celery during storage (p<0.05). PTP showed the lowest L* value and the highest b* value among the tested sausage samples during storage (p<0.05). PTP received the low scores in all the sensory properties of sausages because of its inherent color and flavor. The results suggested that the plasma-treated extract of red perilla was an unsuitable natural nitrite source for cured meat products because of its adverse effect on sensory quality. However, natural nitrite source with increased nitrite content can be produced by the treatment of the natural plant extract with atmosphericpressure plasma.
        4,000원
        7.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        바이오존의 대기압 플라즈마를 사용한 쥐치포(Stephanolepis cirrhifer) 중 미생물안전관리 대상인 B. cereus F4810/72 와 S. aureus ATCC 6538의 저감화 정도 및 품질 특성을 관찰하였다. 대기중의 공기를 활용하여 플라즈마 발생을 유도하여 0 분, 1 분, 3 분, 5 분, 10 분 및 20 분 처리하였다. 이후 대상 미생물의 살균력 평가를 위해 표준평판 법을 사용하여 로그 감소값을 계산하고 Color difference meter를 사용하여 Hunter “L”(명도), ”a”(적색도) 및 “b”(황색도)의 차이를 분석했다. 대기압 플라즈마 3분 처리만으로도 이 두 세균을 1 로그 감소(=90% 감소) 시킬 수 있음이 확인되었다. 아울러 최대 20 분 처리시 쥐치포의 명도, 적색도 및 황색도의 차이는 관찰되지 않았다. 그러나, 본 연구에 사용된 대기압 플라즈마의 기타 수산 건어포와 일반 식품에 대한 산업적 적용을 위해서는 추가적인 목적 미생물의 살균력 연구와 각 품질의 특성을 고려한 품질평가 및 관능평가 등의 추가적인 연구의 확대가 필요하다고 사료된다.
        4,000원
        8.
        2018.10 구독 인증기관·개인회원 무료
        The organism evaluation equipment (OEE) was developed to determine the insecticidal effect of atmospheric-pressure plasma jets (APPJ). The equipment consisted of a plasma-generating acrylic chamber (PGAC) equipped with a plasma generator, a plasma-maintaining acrylic chamber (PMAC), and plasma efficacy evaluation container (PEEC). The amount of reactive oxygen species (ROS) directly exposed to PEEC in the PMAC was measured using an ozone calculator. The ROS concentration in the PGAC and PEEC increased over time, and the optimum position for the PEEC was selected showing the lowest variance of ROS concentration. Based on the established equipment, five major insect pests (Aphis gossypii, Bemisia tabaci, Helicoverpa armigera, Tetranychus kanzawai, and Thrips palmi) were tested, and their knockdown time, recovery time, and median lethal time (LT50) were determined. As a result, B. tabaci showed the fastest knockdown in respond to the plasma, but the remaining insect pests were knock downed within 2-3 min. Recovery was the fastest in T. palmi and T. kanzawai and slowest in B. tabaci. The LT50 were determined as 13 and 16 min in B. tabaci and T. palmi, respectively. However, the LT50 of other insect pests showed over 21 min. In conclusion, the OEE system can be used to measure the optimum exposure time of plasma against various insect pests, and the plasma might be used as an alternative tools for pest control in the future.
        9.
        2018.06 구독 인증기관 무료, 개인회원 유료
        Nonthermal atmospheric plasma has been studied for its many biomedical effects, such as tooth bleaching, wound healing, and coagulation. In this study, the effects of dentinal tubules occlusion were investigated using fluoride-carboxymethyl cellulose (F-CMC) gel, nano-sized hydroxyapatite (n-HA), and nonthermal atmospheric plasma. Human dentin specimens were divided to 5 groups (group C, HA, HAF, HAP, and HAFP). Group HA was treated with n-HA, group HAF was treated with n-HA after a F-CMC gel application, group HAP was treated with n-HA after a plasma treatment and group HAFP was treated with n-HA after a plasma and F-CMC gel treatment. The occlusion of dentinal tubules was investigated using scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS), which shows Ca/P ratio. In the EDS results, a higher Ca/P ratio was shown in the groups including n-HA than in the control group. The specimens of group HAP and HAFP had a higher Ca/P ratio in retentivity. In the SEM results, there was not a significant difference in the amount of times applied. Therefore, this study suggests F-CMC gel and n-HA treatment using nonthermal atmospheric plasma will be a new treatment method for decreasing hypersensitivity.
        4,000원
        10.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 대기압 유전체장벽방전 플라즈마 처리에 따른 식품유해 미생물 사멸효과를 조사하기 위해 수행되었다. 플라즈마 처리 시, 활성종 생성 및 농도에 영향을 미치는 노출시간, 노출거리, 산소비율, 전력 변화에 따른 E. coli의 사멸효과를 조사한 결과, E. coli의 사멸율은 플라즈마 처리를 위한 노출시간, 산소비율, 전력의 증가에 따라 증가한 반면, 노출거리의 증가에 따라서는 사멸율이 감소하였다. 이 결과는 미생물 시료가 플라즈마에 노출되는 시간이 증가됨으로서 시료 내 NO 농도가 증가되고, E.coli의 사멸율 역시 증가되는 결과로 뒷받침할 수 있고, 미 생물 사멸효과를 높이기 위해서는 활성종의 농도가 증가 되어야 함을 의미한다. E. coli와 함께 B. cereus, B. subtilis, B. thuringiensis, B. atrophaeus를 대상으로 대기압 유전체 장벽방전 플라즈마에 의한 살균효과를 조사한 결과, 72.3~91.3%의 높은 사멸율을 나타내었다. 이러한 결과로 미루어, 대기압 유전체장벽방전 플라즈마기술은 다양한 미생물에 적용될 수 있는 유용한 살균기술임을 확인하였다.
        4,000원
        11.
        2017.04 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Reactive Ion Etching (RIE) and wet etching are employed in existing texturing processes to fabricate solar cells. Laser etching is used for particular purposes such as selective etching for grooves. However, such processes require a higher level of cost and longer processing time and those factors affect the unit cost of each process of fabricating solar cells. As a way to reduce the unit cost of this process of making solar cells, an atmospheric plasma source will be employed in this study for the texturing of crystalline silicon wafers. In this study, we produced the atmospheric plasma source and examined its basic properties. Then, using the prepared atmospheric plasma source, we performed the texturing process of crystalline silicon wafers. The results obtained from texturing processes employing the atmospheric plasma source and employing RIE were examined and compared with each other. The average reflectance of the specimens obtained from the atmospheric plasma texturing process was 7.88 %, while that of specimens obtained from the texturing process employing RIE was 8.04 %. Surface morphologies of textured wafers were examined and measured through Scanning Electron Microscopy (SEM) and similar shapes of reactive ion etched wafers were found. The Power Conversion Efficiencies (PCE) of the solar cells manufactured through each process were 16.97 % (atmospheric plasma texturing) and 16.29% (RIE texturing).
        4,000원
        12.
        2016.12 구독 인증기관 무료, 개인회원 유료
        This study was undertaken to achieve a high bleaching efficacy with plasma, through longer application and reparative bleaching processes, by different shade evaluation methods. Extracted human teeth were divided into 6 groups (n=10). All teeth were treated in pairs. Low concentration of 15% carbamide peroxide (CP) was applied, with and without plasma, for 10, 20, and 30-min tooth bleaching, respectively. The bleaching procedure was repeated once daily for four days. The teeth were maintained in a moist environment provided by artificial saliva. The Vitapan Classical shade guide and Commission Internationale de L’Eclairage (CIELAB) color system were collectively used to measure the bleaching efficacy. Color evaluation was statistically analyzed using Student t-test and one-way analysis of variance (ANOVA) complemented by Tukey’s test. Combining the plasma with 15% CP showed significantly greater color changes compared to bleaching without plasma (p<0.05). A high bleaching efficacy with plasma is proportional to the repetitive application and the treatment time. A 30-min application with plasma provided the best bleaching. Repetitive bleaching showed lower probability of color relapse of the bleached tooth. The color change by shade guide correlated with the changes in CIELAB color system. A value of 1 color change units (CCU) conversion factor for overall color change (ΔE) values comparisons was 3.724 values. The two measuring methods provide a more accurate correspondence of color change. The repetitive and longer application for tooth bleaching, combined with plasma, has a strong bleaching effect and produces whiter teeth.
        4,000원
        13.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        국내 시판 중인 선식의 유통 안전성 확보를 위한 기초기반연구로 대기압 플라즈마 처리한 선식의 품질 특성 평가를 진행하였다. 본 연구에서 이용한 플라즈마는 컨테이너형 유전격벽 플라즈마로 방전 가스는 공기를 활용하여 0, 5, 10 및 20분 처리하였고 미생물 감균효과, 색도, pH관능평가를 진행하였다. 일반 호기성 미생물 분석 결과 20분 처리 시 약 1.70 log CFU/g 감소하였으며 B. cereus, B. subtilis 및 E. coli O157:H7을 이용한 접종 시험 결과 각각 2.20, 2.22 및 2.50 log CFU/g 감소하였다. 색도 측정결과 플라즈마 처리에 의해 명도 값은 증가하였으나 적색도 및 황색도는 감소하였다. 플라즈마 처리에 의한 선식의 pH측정 결과 처리시간에 따라 감소하는 경향을 보였다. 하지만 플라즈마 처리에 의해 단백질 지질산화가 일어나 관능 품질이 저하되는 경향을 보였다. 따라서 공기로 방전된 대기압 플라즈마 기술은 선식의 품질안전성을 개선할 수 있으나, 관능적 품질 특성 개선을 위한 후속연구가 필요하다고 판단된다.
        4,000원
        14.
        2016.10 구독 인증기관·개인회원 무료
        Effects of dielectric barrier discharge atmospheric cold plasma (DACP) treatment on the inhibition of Salmonella and the storability of grape tomato were investigated. Grape tomatoes, with or without inoculation with a cocktail of three strains of Salmonella (~8 log CFU/g tomato), were packaged in a polyethylene terephthalate commercial clamshell container and cold plasma-treated at 35 kVat 1.1 kHz for 3 min using an DACP treatment system equipped with a pin-type high-voltage electrode. DACP treatment resulted in ~1 log CFU/tomato reduction of Salmonella, irrespectively of the size of container (316, 595vs. 758 cm3), the number of grape tomatoes in the container (3, 7, vs. 11), and the position of the tomato in the container(P > 0.05).Rolling integrated during treatment significantly increased the Salmonella reduction rates to 3.1±0.3 and 3.3±0.8 log CFU/tomato in the single-layer and double-layer configurations of the tomato samples in the container (992 cm3), respectively. Rolling-adopted DACP initially reduced the number of total mesophilic aerobes and yeast and molds in the double layer configuration of tomato samples by 1.3±0.3 and 1.5±0.2 log CFU/tomato, respectively, without altering the color and firmness of the tomatoes. The growth of Salmonella, total aerobes, and yeast and molds on DACP-treated grape tomatoes was effectively prevented during storage at 10 °C. DACP treatment did not influence the tomato color index (a*/b*), firmness, weight loss, pH, total soluble solid content, and lycopene concentration of grape tomatoes at 10 and 25 °C (P> 0.05). DACP treatment holds promise as a post-packaging process for improving microbial safety against Salmonella and storability of fresh grape tomatoes.
        15.
        2015.12 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate the antibacterial effect of the low temperature atmospheric plasma device with needle tip designed for easy approach to the oral cavity and root canal against Streptococcus mutans, Enterococcus faecalis and Candida albicans. The antibacterial activities evaluated by measuring clear zone of agar plate smeared with each bacteria after plasma treatment. To quantify antibacterial effects, dilution plate method was used. In addition, scanning electron microscope (SEM) was used for observation of changes in bacterial morphology. As treatment time of plasma increased, the clear zone was enlarged. The death rate was more than 99%. The SEM results showed that the globular shape of bacteria was distorted. These results suggest that needle tip plasma could be an innovative device for prevention of dental caries, and treatment of apical infection and soft tissue diseases.
        4,000원
        16.
        2015.11 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Atmospheric pressure plasma is used in the biological and medical fields. Miniaturization and safety are important in the application of apply atmospheric plasma to bio devices. In this study, we made a small, pocket-sized inverter for the discharge of atmospheric plasma. We used pulse power to control the neutral gas temperature at which the, when plasma was discharged. We used direct current of 5 V of bias(voltage). The output voltage is about 1 to 2 kilo volts the frequency is about 80 kilo hertz. We analyzsed the characteristics of the atmospheric plasma using OES(Optical emission spectroscopy) and the Current-Voltage characteristic of pulse power. By calculating of the current voltage characteristics, we were able to determine that, when the duty ratio increased, the power that actually effects the plasma discharge also increased. To apply atmospheric plasma to human organisms, the temperature is the most important factor, we were able to control the temperature by modulating the pulse power duty ratio. This means we can use atmospheric plasma on the human body or in other areas of the medical field.
        4,000원
        17.
        2014.12 구독 인증기관 무료, 개인회원 유료
        Nonthermal atmospheric pressure plasma has attracted great interest for biomedical applications. The plasma consists of charged particles, radicals, and a strong electric field as the fourth state of matter. This study evaluated the change in the surface roughness after tooth bleaching by plasma in combination with a low concentration (15%) of carbamide peroxide, specifically whether the application of plasma produced detriments, such as demineralization and structural change, with the goal of efficient and safe tooth bleaching. After being combined with plasma and 15% carbamide peroxide, the hydroxyapatite surface was significantly smoother with a low roughness average value. Tooth bleaching with 15% carbamide peroxide alone produced an irregular surface and increased the surface roughness with high roughness average value. Tooth bleaching with plasma resulted in no significant variations in hydroxyapatite in terms of change in surface roughness and surface topography. The application of tooth bleaching with plasma is not deleterious to dental hard tissue, implicating it as a safe tooth bleaching technique.
        4,000원
        19.
        2009.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Plasma spray forming is recently explored as a near-net-shape fabrication route for ultra-high temperature metals and ceramics. In this study, monolithic tungsten has been produced using an atmospheric plasma spray forming and subsequent high temperature sintering. The spray-formed tungsten preform from different processing parameters has been evaluated in terms of metallurgical aspects, such as density, oxygen content and hardness. A well-defined lamellae structure was formed in the as-sprayed deposit by spreading of completely molten droplets, with incorporating small amounts of unmelted/partially-melted particles. Plasma sprayed tungsten deposit had 84-87% theoretical density and 0.2-0.3 wt.% oxygen content. Subsequent sintering at 2500 promoted the formation of equiaxed grain structure and the production of dense preform up to 98% theoretical density.
        4,000원
        1 2