검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 2

        1.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Background: Delivery workers repeatedly get in and out of trucks and walk or run to deliver packages during work. Iliotibial band syndrome (ITBS) is a well-known non-traumatic overuse injury of the lateral side of the knee caused by frequent knee flexion and extension. Hip muscle strength is among the factors that prevent lower extremity injuries. Although many studies have examined the relationship between ITBS and hip muscle strengths, there was no study comparing hip muscle strength and ratio between delivery workers with and without ITBS. Objects: This study aimed to compare hip muscle strength and hip internal/external rotator and adductor/abductor strength ratios between delivery workers with and without ITBS. Methods: Fourteen delivery workers with ITBS matched inclusion criteria in the present study among 20 participants. Because total sample size was required 28 subjects by G*power program (ver. 3.1.9.4; University of Trier), 14 delivery workers without ITBS were recruited. Hip muscle strengths were measured in a side-lying position using a Smart KEMA pulling sensor (KOREATECH Co. Ltd.). An independent t-test was used to compare hip muscle strengths and hip internal/external rotator and hip adductor/abductor strength ratios between delivery workers with and without ITBS. Results: The adductor/abductor strength ratio was significantly greater in delivery workers without ITBS than in those with ITBS (p < 0.05). The strengths of the hip abductor, hip adductor, hip internal rotator, hip external rotator, and the ratio of internal/external rotator strengths were not significantly different between the delivery workers with and without ITBS (p > 0.05). Conclusion: This study’s findings showed that delivery workers with ITBS had significantly lesser adductor/abductor strength ratio, while the strengths of the hip abductor and adductor muscles did not differ significantly. These results suggest that adductor/abductor strength ratio should be considered when evaluating and treating ITBS in delivery workers.
        4,000원
        2.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        DLC has been attractive as semiconductor materials for solar cell due to its biological friendliness, flexible microstructures, and especially its tunable band gap. In order to fabricate high-efficiency multiband gap solar cell, it is important to control the sp3/ sp2 bonds ratio of DLC film corresponding to optical band gap (Eg). There are many references reporting the relations among the fabrication conditions, Eg, sp3/ sp2, and ID/ IG. However, a more comprehensive database is needed for controllable fabrication. Especially, the quantitative relationship of sp3/ sp2 ratio to Eg of DLC film by PECVD is unclear. In this paper, 36 sets of DLC films were fabricated by RF-PECVD. Characterization methods of XPS, Raman spectroscopy, and IR absorption have been used to determine the sp3/ sp2 ratio of DLC films. UV/visible light absorption method has applied to evaluate Eg. The Eg obtained is in the range 1.45–3.0 eV. Our results agree well with the references. The XPS spectra gives a linear relationship as Eg = − 0.161 (± 0.136) + 26.095 (± 1.704) · {sp3 (XPS)/sp2}, the Raman spectra shows a linear function that Eg = 1.327 (± 0.046) + 0.428 (± 0.036) · (ID/IG), as well as the FTIR analysis demonstrates that Eg = − 0.492 (± 0.093) + 0.464 (± 0.044) · {sp3 (FTIR)/sp2}.
        4,200원