검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 6

        1.
        2023.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Existing reinforced concrete buildings with seismically deficient details have premature failure under earthquake loads. The fiber-reinforced polymer column jacket enhances the lateral resisting capacities with additional confining pressures. This paper aims to quantify the retrofit effect varying the confinement and stiffness-related parameters under three earthquake scenarios and establish the retrofit strategy. The retrofit effects were estimated by comparing energy demands between non-retrofitted and retrofitted conditions. The retrofit design parameters are determined considering seismic hazard levels to maximize the retrofit effects. The critical parameters of the retrofit system were determined by the confinement-related parameters at moderate and high seismic levels and the stiffness-related parameters at low seismic levels.
        4,000원
        2.
        2006.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 도로교의 교각으로 널리 사용되고 있는 2주형 철근 콘크리트 교각의 내진성능과 보강방안을 실험적으로 수행하였다. 실험체는 지름 400mm, 높이 2,000mm인 2주형 원형교각 10기를 제작하였으며, 하중은 0.1f_{ck}A_g 크기의 축방향하중하에서 교축방향과 교축직각방향의 이축 횡방향하중을 교번 반복재하하였다. 실험변수는 심부구속철근비, 주하중방향, 주철근 겹침이음 그리고 보강방안을 선택하였다. 주철근 겹침이음이 있는 교각에 대한 보강방안으로 steel band, steel jacket, 그리고 prestress 강선을 이용하였다. 실험 결과 주하중방향이 교축직각인 실험체가 소성힌지구간이 교각의 상 하부 양측에 발생하면서 주하중 방향이 교축방향인 실험체보다 연성 능력이 우수한 것으로 나타났다. 프리스트레스 강선으로 보강한 실험체는 과보강으로 인한 소성힌지구간의 이동으로 연성도 저하가 나타났으나, steel jacket 및 steel band로 보강한 실험체는 모두 요구연성도를 만족하는 것으로 나타났다. 특히, steel band에 의한 보강방안은 시공성 등을 감안하여 바람직한 철근 콘크리트 교각의 내진 보강방안으로 고려될 수 있다.
        4,000원
        3.
        2017.04 서비스 종료(열람 제한)
        Seismic performance capacity of CFT seismic retrofit method was studied through cyclic loading test. The added CFT columns share the lateral seismic force of the building with the existing RC columns to prevent building collapse. The experiment shows stable hysteric load-displacement curve.
        4.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        Seismic performance capacity of CFT seismic retrofit method was studied through cyclic loading test. The added CFT columns share the lateral seismic force of the building with the existing RC columns to prevent building collapse. The experiment shows stable hysteric load-displacement curve.
        5.
        2013.04 서비스 종료(열람 제한)
        To evaluate the ductility of high strength steel beam-to-column connections, Cycle loading connection test was conducted targeting HSA800 steel being developed in Korea and parameter is connection details. According to the study, The non-scallop detail and improved horizontal rib reinforcement detail used in this study enhanced deformation capacity of high strength steel connections which have brittle tendency by stress relaxation.
        6.
        2010.11 KCI 등재 서비스 종료(열람 제한)
        최근 국내에서도 지진의 발생 가능성이 증가하는 추세이며 교량 및 터널 등의 시설물에 대한 지진과 같은 예상하지 못한 작용하중에 대한 안전성을 강화하고 있다. 특히, 1988년 이전 건설된 도시철도 시설물의 대부분은 내진설계가 반영되지 않아 지진하중에 대해 취약할 수 있으므로, 내진안전성에 대한 검토와 보강이 요구되고 있다. 이 연구에서는 도시철도 개착식 터널의 내진성능 향상을 도모하고자, 구조적 취약부분인 내측 기둥에 내진보강을 위한 새로운 FRP-연성재 적층복합체를 제안하였다. 적층조건에 따른 FRP-연성재 적층복합체에 대한 실험을 통해 재료물성치를 산출하여, 이를 근간으로 수치모델을 작성하였다. 수치해석을 통해 제안된 보강재로 보강된 RC기둥의 내진성능이 증대됨을 알 수 있었다. 또한 섬유보강재의 적층조건 (연성재의 종류, FRP 적층수, 섬유배향각)에 따라 성능 향상의 차이가 있는 것을 확인할 수 있었다.