검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 7

        1.
        2006.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문은 콘크리트 충전 원형 및 각형 합성 강관을 기둥부재로서의 적합성 및 적용성을 위한 연구로 두개의 강관을 합성한 콘크리트 충전 강관 기둥의 축압축 좌굴내력 및 변형형상에 대한 실험적 연구이다. 강관 기둥에 대한 연구는 콘크리트 충전 원형 강관 기둥, 콘크리트 충전 각형 강관 기둥, 콘크리트 충전 합성 강관 기둥으로 분류하여 실험을 수행하였다.
        4,000원
        2.
        2003.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper is presented an experimental studies on bond stress between steel and concrete in concrete filled Rectangular steel tubes. In the actual building frames, vertical dead and live loads on beams are usually transferred to columns by beam-to-column connections. In case when concrete filled steel tubes are used as columns of an actual building frame which has a simple connection, shear forces in the beam ends are not directly transferred to the concrete core but directly to the steel tube. Provided that the bond effect between steel tube and concrete core should not be expected, none of the end shear in the beams would be transferred to the concrete core but only to the steel tube. Therefore, it is important to investigate the bond strength between steel tube and concrete core in the absence of shear connectors.
        4,000원
        3.
        2002.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper is presented an experimental studies on bond stress between steel and concrete in concrete filled steel tubes. In the actual building frames, vertical dead and live loads on beams are usually transferred to columns by beam-to-column connections. In case when concrete filled steel tubes are used as columns of an actual building frame which has a simple connection, shear forces in the beam ends are not directly transferred to the concrete core but directly to the steel tube. Provided that the bond effect between steel tube and concrete core should not be expected, none of the end shear in the beams would be transferred to the concrete core but only to the steel tube. Therefore, it is important to investigate the bond strength between steel tube and concrete core in the absence of shear connectors.
        4,000원
        4.
        2001.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper is to estimate the load carrying capacities of concrete-filled steel tubular columns and the important parameters are selected the size, length and concrete strength. he concrete-filled tube structures has many excellent structural properties, that is, high load capacity, good plastic deformation and high resistance local buckling. Under these background, this study Investigated to the structural compression behaviors, the maximum strength, the confinement effects, the fracture mechanism, local buckling failure and concrete strength effects.
        4,000원
        5.
        2015.03 KCI 등재 서비스 종료(열람 제한)
        For the safe design of steel-concrete composite structure, usable yield strength of steels are limited in most of design standard. However, this limitation sometimes cause the uneconomical design for some kind of members such as slender columns which was affected by elastic buckling load. For the economical design for slender columns, parametric study of RCFT (Rectangular CFT) with high-strength steel is conducted, especially investigating the limitation of yield strength of high-strength steels. Using ABAQUS, finite element analysis program, the finite element model was constructed and calibrated with experimental study for RCFT with high strength steel which have yield strength up to 680MPa. Investigated design parameters are yield strength of steel, compressive strength of concrete, steel thickness and slenderness ratio. The effect of desgn parameters were compared with design standard, KBC-09. From the parametric study with 54 models and previous test specimens, RCFT can be safely design with higher yield strength of steels than currently limited by KBC for large range of slenderness ratio.
        6.
        2009.05 KCI 등재 서비스 종료(열람 제한)
        본 연구는 기존의 CFT구조, 아치구조, 프리스트레스구조를 조합을 통해 복합구조를 이루는 CFTA거더를 소개하고, 25m의 CFTA거더의 실험결과와 유한요소해석 프로그램인 Strand7을 이용하여 해석결과를 비교 분석하였다. 실험체의 정적재하실험으로 거더 중심부에서 양쪽으로 1m 이격한 거리에 58kN, 88kN, 148kN, 207kN, 298kN의 하중을 재하 하고, 발생하는 변위와 변형률을 측정하였다. 또한, 실험결과를 바탕으로 구조해석 프로그램인 Strand7로 구조안정성을 검토하고, 긴장재의 긴장력과 콘크리트의 탄성계수를 각각 20%증감하여 해석을 수행 하여 변형률과 변위값을 계산하였다. 초기 변위와 변형률은 긴장재의 긴장력의 증감에 따라 영향이 나타났으며, 추가적인 정적 하중이 재하 되었을 경우에는 콘크리트의 탄성계수만이 변위와 변형률에 영향을 미치는 것으로 확인 되었다.