        검색결과 25

        1.
        2023.11 구독 인증기관·개인회원 무료
        The cyclotron is an apparatus used for the production of radioactive isotopes through nuclear reactions, resulting in the inevitable emission of neutrons. Consequently, surrounding components become activated. The purpose of this study was to investigate the radiological characteristics of Havar foil, a periodic replacement part of the Targetry system. In this study, radioactivity and radiation dose were calculated based on the time of Havar foil replacement and equipment dismantling. The time to dismantle the equipment was set at one year after the equipment was shut down, based on the recently used 1g of Havar foil. All simulations were performed using the FLUKA program. First, in the simulation results, 11 elements (Re, W, Tc, Nb, Cu, Ni, Co, Fe, Mn, Cr, V) were converted into 36 radioisotopes by activation based on the replacement period. Based on radioactivity levels, major isotopes included 52Mn (77.63%), 56Co (13.36%), 96Tc (2.4%), and 95Tc (1.80%). Based on radiation dose rates, 52Mn (82.66%) and 56Co (13.45%) exhibited the highest levels. Furthermore, the dose rates at distances of 10 cm, 50 cm, and 100 cm were found to be 1.36E+1 mSv/hr, 2.24E+00 mSv/hr, and 8.80E-01 mSv/hr, respectively. Second, as of the time the equipment was dismantled, 20 radioactive isotopes of 10 elements, excluding short-lived nuclides, were generated. In terms of radioactivity, 56Co (45.83%), 55Fe (19.73%), 57Co (14.48%), and 54Mn (13.50%) were prominent. Regarding radiation dose rates, 56Co (92%) and 54Mn (7.32%) exhibited higher levels. Dose rates at distances of 10 cm, 50 cm, and 100 cm were calculated at 5.31E-01 mSv/hr, 8.80E-02 mSv/hr, and 3.47 E-02 mSv/hr, respectively. Third, according to the radioactive waste classification standards in the replacement and decommissioning stages, Havar foil was predicted to be low-level radioactive waste in terms of radioactivity. In addition, it was derived that a cooling period of approximately 12 years is necessary to satisfy the allowable dose for clearance level waste. In conclusion, Havar foil, which is periodically generated as radioactive waste, can cause radiation exposure to replacement workers. Therefore, special and careful management is required for the Havar foil of the cyclotron.
        2.
        2023.11 구독 인증기관·개인회원 무료
        For safe and successful decommissioning, it is one of the most important procedures that establishing the goal and complying with regulations of which final status of decommissioned site and building. The dose criteria for cyclotron facilities should be established and applied to reuse the site and building, since building and component of a cyclotron facility have been activated by incident secondary neutrons from radioactive isotope processes (e.g. 18O(p,n)18F, etc.). Furthermore, appropriate approaches should be applied to demonstrate compliance with the dose criteria for reliability of reuse. It is of noted that U.S. NRC (Nuclear Regulatory Commission) has confirmed that the residual radioactivity which distinguishable from background radiation results in a TEDE (Total Effective Dose Equivalent) does not exceed 25 mrem (0.25 mSv) per year as radiological criteria for unrestricted use of not only nuclear power plants but also cyclotron facilities referred to 10 CFR Part 20.1402. In addition, U.S. NRC noted the two approaches (i.e. dose assessment methods and, DCGL and final status surveys) which can be applied for demonstrating compliance with the dose criteria of 10 CFR Part 20 and recommended DCGL and FSS approach based on advantages and disadvantages of the two approaches. In order to using DCGL and FSS approach, U.S. NRC suggested screening approach; using DandD Version 2 which assesses TEDE under ICRP 28 and site-specific approach; using all models or computational codes which approved by NRC staff. There are several foreign cases that release of cyclotron facilities after decommissioning (i.e. U.S. and Japan). U.S., for examples, there are two DCGL approach cases and one dose modeling case based on 25 mrem per year same as reactor facilities. The dose modeling case, however, which may not be really used in Korea because of its low applicability. On the other hand, Japan case did not establish any radiological criteria for site and building reuse such as DCGL and just confirm “no more contamination” which is all residual radioactivity is lower than MDC based on real survey. Japan case also may not be used in Korea since criteria of “no more contamination” is not clear and hard to apply for all sites. Considering regulations and criteria for site release and reuse in Korea, this study aims to suggest radiological criteria and the demonstration approach of compliance for decommissioning of cyclotron facilities based on Nuclear Safety Acts and NSSC notices.
        3.
        2022.10 구독 인증기관·개인회원 무료
        Important medical radionuclides for Positron Emission Tomography (PET) are producing using cyclotrons. There are about 1,200 PET cyclotrons operated in 95 countries based upon IAEA database (2020). Besides, including PET cyclotrons, demands for particle accelerators are continuously increasing. In Korea, about 40 PET cyclotrons are in operating phases (2020). Considering design lifetime (about 30-40 years) and actual operating duration (about 20-30 years) of cyclotrons, there will be demands for decommissioning cyclotron facilities in the near future. PET cyclotron produces radionuclides by irradiating accelerated charged particles to the targets. During this phase, nuclear reactions (18O(p,n)18F etc.) produce secondary neutrons which induce neutron activation of accelerator itself as well as surrounding infrastructures (the ancillary subsystems, peripheral equipment, concrete walls etc.). Generally, experienced cyclotron personnel prefer an unshielded cyclotron because of the repair and maintenance time. In unshielded cyclotron, water cooling systems, air compressor, and other equipment and structures could be existed for operating purposes. Almost all the equipment and structures are consisted of steel, and these affect neutron distribution in vault especially thermal neutron on the concrete wall. In addition, most of them can be classified as very low level radioactive wastes by Nuclear Safety and Security notice (NSSC Notice No. 2020-6). However, few studies were estimating radioactivity concentrations (Bq/g) of surrounding structures using mathematical calculation/simulation codes, and they were not evaluating the effect of surrounding structures on neutron distribution. In this study, by using computational neutron transport code (MCNP 6.2), and source term calculation code (FISPACT- II), we evaluated effect of the interaction between surrounding structures (including surrounding equipment) and secondary neutrons. Discrepancies of activation distribution on/in concrete wall will be occur depending on thickness of structure, distance between structures and walls, and consideration of interaction between structures and neutrons. Throughout this study, we could find that the influence of those structures can affect neutron distribution in concrete walls even if, thickness of the structure was small. For estimating activation distribution in unshielded cyclotron vault more precisely, not only considering cyclotron components and geometry of target, but also, considering surrounding structures will be much more helpful.
        4.
        2022.05 구독 인증기관·개인회원 무료
        Korea Institute of Radiological and Medical Sciences provides proton irradiation service of up to 40 MeV using cyclotron. The use of such a cyclotron was approved in advance to satisfy the Nuclear Safety Act, and radiation safety was evaluated in this process. The Monte Carlo method is generally used to evaluate the shielding safety of high-energy accelerators, and MCNP 6.2 was used in the previous evaluation. In this study, in order to verify the results of previous evaluation, the calculation results of MCNP 6.2 and Particle and Heavy Ion Transport code System (PHITS) 3.24 are compared. PHITS is a general-purpose Monte Carlo particle transport simulation code that is used in many studies in the fields of accelerator technology, radiotherapy, space radiation, etc. In the previous evaluation, the effective dose by neutrons and photons generated by the collision of 40 MeV 20 μA of protons with a 10.5 mm thick beryllium target was evaluated, and in this study, this was reproduced with PHITS. As the radiation exposure evaluation for the user or pubic is evaluated based on the radiation dose and energy distribution generated around the target, the effective dose and energy distribution received by the water phantom with a radius of 1 cm on the front, side, and back of the target were calculated. T-Track, a tally of PHITS, was used to calculate effective dose, which is similar to F4 tally of MCNP 6.2 using a dose conversion factor. For the dose conversion factor, the value suggested as AP irradiation in Publication 103 was used. As a result of the calculation, the effective dose by neutrons at the front, side and back of the target was 1.42×105, 2.09×104, and 1.39×104 mSv·h−1, respectively, which was similar to 2.00×105, 1.84×104, and 2.59×104 calculated using F4 tally in MCNP. Moreover, the results of calculating the effective dose by photons using PHITS were 4.81×10, 3.10×10, and 2.66×10, respectively, and the results of calculating MCNP were 4.49×102, 6.45×10, and 9.64×10. The average energies of neutrons were 11.2, 0.69, and 0.31 MeV when calculated by PHITS, respectively, and 13.8, 7.8, and 4.6 when calculated by MCNP. Moreover, the average energies of photons were 1.98, 0.98, and 0.86 when calculated by PHITS, respectively, and 3.9, 3.2, and 2.6 when calculated by MCNP.
        5.
        2022.05 구독 인증기관·개인회원 무료
        In worldwide, tens of thousands of units of particle accelerators have been used and more than 97% of those accelerators are used for dedicated medical of commercial applications. Radionuclide production cyclotron produce several positron-emitting radionuclides such as 18F by 18O(p,n)18F reaction which generates secondary neutrons. It is of note that these neutrons cause neutron activation in structures and components of cyclotron facilities. Therefore, International Atomic Energy Agency had addressed that a well-developed estimate of the neutron activation induced radioactive inventory of accelerator facilities is needed for the proper planning and safe implementation of decommissioning using proven methods or codes that can be used to perform activation calculations. Moreover, IAEA suggested that during the operation of cyclotrons, concrete walls become radioactive over time and this radioactivity needs to be fully characterized as part of early decommissioning planning. In this study, Neutron activation in the medical cyclotron facilities was evaluated with the MCNP and FISPACT-II code to analyze the generation of decommissioning radioactive wastes during facilities dismantling. For the reference case, residual radioactivity concentration of each activation product (e.g. 60Co, 152Eu, etc.) was calculated and the sum of fractions of the activity concentration of each radionuclide divided by its clearance level was exceeded 1.0 at each calculation point which means radioactive waste generations during decommissioning of the facility. Several points show the calculated sum of fractions (SoF) at inside wall were bigger than the surface wall. The reason of these phenomena is that the slowdown of the incident neutron energy at the inside wall due to neutron attenuation and larger thermal neutron flux than surface wall. It is of note that each activation reaction cross-section was dominant at thermal neutron energy band. Sensitivity analysis was conducted to analyze the effects of design characteristics (e.g. beam energy and current, operation period, and workload). The SoF was exceeded 1.0 at the least activation condition (i.e. 9 MeV, 10 μA) if the operation period was 10 years. For the realistic condition such as 13 MeV, only 10 μA of beam current case shows the SoF was under union. On the other hand, 19 MeV, 60 μA, and 10 years operation case shows the SoF as 20.4 which means the clearance rule can be applied only after 21 years of decay-in-storage. The result of this study can be used for proper planning of decommissioning and/or new installation of cyclotron facilities include considerations of radioactive waste management.
        6.
        2022.05 구독 인증기관·개인회원 무료
        For producing radionuclides which were mostly used in medical purposes, for instance, Positron Emission Tomography (PET), there were about 1,200 PET cyclotrons operated in 95 countries based upon IAEA database (2020). Besides, including PET cyclotrons, demands for particle accelerators are continuously increasing. In Korea, about 40 PET cyclotrons are in operating phases (2020). Considering design lifetime (about 30–40 years) of cyclotrons, there will be demands for decommissioning cyclotron facilities in the near future. PET cyclotron produces radionuclides by irradiating charged particles to the targets. During this phase, nuclear reactions (18O(p,n)18F, 14N(d,n)15O etc.) produce secondary neutrons which induce neutron activation of accelerator itself as well as surrounding infrastructures (the ancillary subsystems, peripheral equipment, concrete walls etc.). Most of the ancillary systems including peripheral equipment can be neutron activated, since, most of them were made of steels. Steels like stainless steel or carbon steel may contain some impurities, typically cobalt. Although, there were several researches evaluating activation of concrete walls and accelerator components, estimating the activation and influence on neutron interaction of the other surrounding infrastructures were insufficient. In this study, by using computational neutron transport code (MCNP 6.2), and source term calculation code (FISPACT- II), we estimated neutron distribution in cyclotron vault and activation of ancillary subsystems including some peripheral equipment. Also, using Au foil and Cd cover, we measured thermal neutron distribution at 16 points on the concrete wall, and compared it to calculated results (MCNP). Even though, the compared results matches well, there was a discrepancy of neutron distributions between presence and absence of those equipment. Additionally, in estimating activation distributions by calculating, most of the steel-based subsystems including peripheral equipment should be managed by radioactive wastes after 20 years of operation. Throughout this study, we could find that influence on neutron interaction of those equipment can affect neutron distribution in concrete walls. This results vary the activation depth as well as location of the hot contaminated spot in concrete wall. For estimating or evaluating activation distributions in cyclotron facilities, there was need to consider some equipment located in cyclotron vault.
        11.
        2017.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Aluminum-oxide(Al2O3) thin films were deposited by electron cyclotron resonance plasma-enhanced atomic layer deposition at room temperature using trimethylaluminum(TMA) as the Al source and O2 plasma as the oxidant. In order to compare our results with those obtained using the conventional thermal ALD method, Al2O3 films were also deposited with TMA and H2O as reactants at 280 oC. The chemical composition and microstructure of the as-deposited Al2O3 films were characterized by X-ray diffraction(XRD), X-ray photo-electric spectroscopy(XPS), atomic force microscopy(AFM) and transmission electron microscopy(TEM). Optical properties of the Al2O3 films were characterized using UV-vis and ellipsometry measurements. Electrical properties were characterized by capacitance-frequency and current-voltage measurements. Using the ECR method, a growth rate of 0.18 nm/cycle was achieved, which is much higher than the growth rate of 0.14 nm/cycle obtained using thermal ALD. Excellent dielectric and insulating properties were demonstrated for both Al2O3 films.
        4,000원
        14.
        1998.04 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        SiH4를 반응물질로 사용하여 electron cyclotron resonance plasma enhanced chemical vapor deposition(ECR-PECVD)로 실리콘 기판위에 증착한 수소화 비정질 실리콘(a-Si:H)으로부터 가시 photoluminescence(PL) 가 관찰되었다. a-si:H/Si로 부터의 PL은 다공질실리콘으로부터의 PL과 유사하였다. 급속열처리에 의해 500˚C에서 2분간 산소분위기에서 어닐링된 시편의 수소함량은 1~2%로 줄어들었고 시편은 가시 PL을 보여주지 않았는데 이는 a-Si:H의 PL과정에서 수소가 중요한 역할을 한다는 것을 뜻한다. 증착된 a-Si:H의 두께가 증가함에 따라 PL의 세기는 감소하였다. SiH4를 사용하여 ECR-PECVD에 의해 Si상에 증착된 a-Si:H로부터의 가시 PL은 Si과 증착된 a-Si:H막 사이에 증착이 이루어지는 동안에 형성된 수소화실리콘으로부터 나오는 것으로 추론된다.
        3,000원
        15.
        2022.06 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        The elements that impact the dynamics and collaborations of waves and particles in the magnetosphere of planets have been considered here. Saturn’s internal magnetosphere is determined by substantiated instabilities and discovered to be an exceptional zone of wave activity. Interchanged instability is found to be one of the responsible events in view of temperature anisotropy and energization processes of magnetospheric species. The generated active ions alongside electrons that constitute the populations of highly magnetized planets like Saturn’s ring electron current are taken into consideration in the current framework. The previous and similar method of characteristics and the perturbed distribution function have been used to derive dispersion relation. In incorporating this investigation, the characteristics of electromagnetic ion cyclotron wave (EMIC) waves are determined by the composition of ions in plasmas through which the waves propagate. The effect of ring distribution illustrates non-monotonous description on growth rate (GR) depending upon plasma parameters picked out. Observations made by Cassini found appropriate for modern study, have been applied to the Kronian magnetosphere. Using Maxwellian ring distribution function of ions and detailed mathematical formulation, an expression for dispersion relation as well as GR and real frequency (RF) are evaluated. Analysis of plasma parameters shows that, proliferating EMIC waves are not developed much when propagation is parallelly aligned with magnetosphere as compared to waves propagating in oblique direction. GR for the oblique case, is influenced by temperature anisotropy as well as by alternating current (AC) frequency, whereas it is much affected only by AC frequency for parallel propagating waves.
        16.
        2022.06 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        During their respective missions, the spacecraft Voyager and Cassini measured several Saturn magnetosphere parameters at different radial distances. As a result of information gathered throughout the journey, Voyager 1 discovered hot and cold electron distribution components, number density, and energy in the 6–18 Rs range. Observations made by Voyager of intensity fluctuations in the 20–30 keV range show electrons are situated in the resonance spectrum’s high energy tail. Plasma waves in the magnetosphere can be used to locate Saturn’s inner magnetosphere’s plasma clusters, which are controlled by Saturn’s spin. Electromagnetic electron cyclotron (EMEC) wave ring distribution function has been investigated. Kinetic and linear approaches have been used to study electromagnetic cyclotron (EMEC) wave propagation. EMEC waves’ stability can be assessed by analyzing the dispersion relation’s effect on the ring distribution function. The primary goal of this study is to determine the impact of the magnetosphere parameters which is observed by Cassini. The magnetosphere of Saturn has also been observed. When the plasma parameters are increased as the distribution index, the growth/damping rate increases until the magnetic field model affects the magnetic field at equator, as can be seen in the graphs. We discuss the outputs of our model in the context of measurements made in situ by the Cassini spacecraft.
        17.
        2019.06 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        The Earth’s outer radiation belt has long received considerable attention mainly because the MeV electron flux in the belt varies often dramatically and at various time scales. It is now widely accepted that the wave-particle interaction is one of the major mechanisms responsible for such flux variations. The wave-particle interaction can accelerate electrons to MeV energies, explaining the observed flux increase events, and can also scatter the electrons’ motion into the loss cone, resulting in atmospheric precipitation and thus contributing to flux dropouts. In this paper, we provide a review of the current state of research on relativistic electron scattering and precipitation due to the interaction with electromagnetic ion cyclotron (EMIC) waves in the inner magnetosphere. The review is intended to cover progress made over the last ~15 years in the theory and simulations of various issues, including quasilinear resonance diffusion, nonlinear interactions, nonresonant interactions, effects of finite normal angle on pitch angle scattering, effects due to rising tone emission, and ways to scatter near-equatorial pitch angle electrons. The review concludes with suggestions of a few promising topics for future research.
        18.
        2019.02 KCI 등재 서비스 종료(열람 제한)
        사이클로트론 가동 시 핵반응으로 인해 중성자가 발생되며, 발생된 중성자는 콘크리트벽에 흡수되어 방 사화를 일으키게 된다. 이에 본 연구에서는 콘크리트 종류에 따른 방사화 분석과 방사화 핵종이 미치는 영향에 대해 알아보고자 하였다. 실험은 몬테카를로 시뮬레이션 및 RESRAD 모델을 사용하였다. 실험 결과 콘크리트의 Fe 함유량이 높을수록 차폐율이 증가하였으며, Fe은 56Fe(n, 2np)54Mn 반응으로 인하여 종사자 에게 미치는 영향 또한 같이 증가하였다. 하지만, 방사화로 생성된 핵종의 방사능은 매우 낮게 나타나 종사 자들에게 미치는 영향은 매우 낮은 것으로 나타났다. 방사화된 콘크리트 해체 처분 시 방사능이 자체처분 한도 미만으로 일반폐기물로써 처리되어야 하며, 14C의 영향을 최소화하기 위해 매립이 아닌 도로 보수와 같은 표층에 재활용 되어야 할 것이다.
        19.
        2018.10 KCI 등재 서비스 종료(열람 제한)
        의료용 사이크로트론은 방사성의약품을 생산하기 위해 양성자를 고속으로 가속시켜 핵반응을 일으키게 되며, 핵반응을 통해 불필요한 중성자가 발생하게 된다. 중성자는 사이클로트론의 부품에 방사화를 일으키는 원인으로 종사자들의 피폭의 원인이 된다. 이에 본 연구에서는 핵반응이 일어나는 Targetry 부품들인 Aluminum body, Silver body, Havar foil의 방사화 정도를 분석하여 피폭선량을 알아보고자 하였다. 실험결과 Aluminum body와 Silver body는 방사화된 핵종들의 에너지가 작고, 반감기가 짧아 종사들에게 미치는 선량이 미미하였으며, 재사용하는데 문제가 없었다. 하지만 Havar foil의 경우 방사화된 핵종들의 에너지가 높고 반감기가 길어 종사자들에게 미치는 영향이 매우 높았으며, 방사성폐기물로써 특별한 관리가 필용한 것으로 나타났다.
        20.
        2018.03 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        Pc1 pulsations are geomagnetic fluctuations in the frequency range of 0.2 to 5 Hz. There have been several observations of Pc1 pulsations in low earth orbit by MAGSAT, DE-2, Viking, Freja, CHAMP, and SWARM satellites. However, there has been a clear limitation in resolving the spatial and temporal variations of the pulsation by using a single-point observation by a single satellite. To overcome such limitations of previous observations, a new space mission was recently initiated, using the concept of multi-satellites, named the Small scale magNetospheric and Ionospheric Plasma Experiments (SNIPE). The SNIPE mission consists of four nanosatellites (~10 kg), which will be launched into a polar orbit at an altitude of 600 km (TBD) in 2020. Four satellites will be deployed in orbit, and the distances between each satellite will be controlled from 10 to 1,000 km by a highend formation-flying algorithm. One of the possible science targets of the SNIPE mission is observing electromagnetic ion cyclotron (EMIC) waves. In this paper, we report on examples of observations, showing the limitations of previous EMIC observations in low earth orbit, and suggest possibilities to overcome those limitations through a new mission.