        검색결과 49

        41.
        2018.10 KCI 등재 서비스 종료(열람 제한)
        DeNOx experiments for the effects of hydrocarbon additives on diesel SNCR process were conducted under oxidizing diesel exhaust conditions. A diesel-fueled combustion system was set up to simulate the actual cylinder and head, exhaust pipe and combustion products, where the reducing agent NH3 and C2H6/diesel fuel additives were separately or simultaneously injected into the exhaust pipe, used as the SNCR flow reactor. A wide range of air/fuel ratios (A/F=20~40) were maintained, based on engine speeds where an initial NOx level was 530 ppm and the molar ratios (β=NH3/NOx) ranged between 1.0~2.0, together with adjusting the amounts of hydrocarbon additives. Temperature windows were normally formed in the range of 1200~1350K, which were shifted downwards by 50~100K with injecting C2H6/diesel fuel additives. About 50~68% NOx reduction was possible with the above molar ratios (β) at the optimum flow #1 (Tin=1260K). Injecting a small amount of C2H6 or diesel fuel (γ=hydrocarbon/NOx) gave the promising results, particularly in the lower exhaust temperatures, by contributing to the sufficient production of active radicals (OH/O/HO2/H) for NOx reduction. Unfortunately, the addition of hydrocarbons increased the concentrations of byproducts such as CO, UHC, N2O and NO2, and their emission levels are discussed. Among them, Injecting diesel fuel together with the primary reductant seems to be more encouraging for practical reason and could be suggested as an alternative SNCR DeNOx strategy under diesel exhaust systems, following further optimization of chemicals used for lower emission levels of byproducts.
        42.
        2017.07 KCI 등재 서비스 종료(열람 제한)
        The use of electrical and electronic products made of low specific gravity and easy processing plastics has increased alongside industrial development. As these products were abandoned, environmental problems such as Dioxine and Furan began to rise. Accordingly, through long-time reviews and discussions, the EU has implemented the Restriction of Hazardous Substances (RoHS) and the Waste Electrical and Electronic Equipment (WEEE) regulations. In addition, the Stockholm Convention was adopted in April 2011 to regulate wastes containing brominated flame retardants. Therefore, the Basel Convention issued technical guidelines and environmentally friendly treatments for wastes containing brominated flame retardants. Proper management and treatment plans that are suitable to Korea’s circumstances are required for Korea to respond to both conventions and changing trends in international POPs management. In this regard, the study identified domestic and international trends in environmental regulations and usages, obtained fundamental data for the management of waste containing brominated flame retardants, and investigated the current status of waste generation in Korea. The results of analyses were used to make a lab-scale incineration reactor as the basis for setting incineration temperature ranges for experiments. After incineration, five general air pollutants (O2, CO, CO2, SOx, and NOx) and three components of BRFs in emission gases and flooring were analyzed to identify whether the PBDEs in waste can be destroyed in a stable and environmental manner during heat treatment. In the analysis, HRMS was used for PBDEs and GC/MS/MS for TBBPA and HBCD. PBDD/DFs was proportionally increased in facilities that had high concentrations of PCDD/DFs during incineration. In conclusion, wastes containing brominated flame retardants in Korea can be incinerated in an environmentally friendly manner.
        43.
        2016.09 KCI 등재 서비스 종료(열람 제한)
        Characteristics of the exhaust gas of a commercial scale (7.2 ton/day) municipal wastes incinerator with recirculation of its high temperature combustion gas were investigated. High temperature combustion gas made by incineration was entrained by an air jet and re-used for incineration. Air was preheated to 384-512oC and diluted to have an oxygen concentration of 16-17%. Incineration of municipal wastes with the preheated and diluted air made extremely uniform and stable flames. Concentrations of nitric oxide (NOx), carbon monoxide (CO), oxygen (O2), and carbon dioxide (CO2) in flue gas were measured at the boiler exit and the stack, simultaneously. Averaged concentrations of NOx and CO were reduced to 54.2 ppm and 3.1 ppm at the boiler exit and to 49.8 ppm and 6.0 ppm at the stack, respectively, at a reference oxygen concentration of 12% without any post treatment of NOx and when the averaged outlet temperature of the combustion chamber was 904oC. The measured NOx emission was only 29% of that of a conventional municipal incinerator. Simultaneous reduction of NOx and CO is significant. Averaged concentrations of O2 and CO2 were 9.7% and 8.6% at the boiler exit and 14.6% and 4.9% at the stack, respectively.
        44.
        2016.02 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 선박에서 발생하는 대기오염물질을 처리하기 위해 사용되는 습식 스크러버를 이용한 배기가스 세정시스템(EGCS: Exhaust Gas Cleaning System)에서 발생되는 폐수를 재이용 할 수 있는 순환시스템을 개발하기 위해 진행되었다. 선박 배기가스 DePM, DeSOx 순환처리장치 (Recycle system)의 세정수의 입자성물질과 분산유를 효과적으로 제거할 수 있는 수 처리 시스템을 개발한 결과 원심 분리형 Purifier만으로는 미세한 분산유의 처리가 어렵다는 결과가 도출되어 원심분리형 Purifier 후처리로 유수분리 경사 분리판을 이용한 유 수분리기의 일종인 Coalescer를 본 시스템에 적용하였다. Coalescer는 2차 분산 상태의 에멀젼화 된 미세 기름입자를 합착시켜 분리하는 기술 이다. 선박 배기가스 DePM, DeSOx 순환처리장치 (Recycle system)에서 배출되는 세정수를 Purifier와 Coalescer를 이용하여 처리한 결과 입자성물질은 55% 분산유는 유입수 대비 99%이상 처리되는 것을 확인하였다. 따라서 선박 대기오염 저감을 위한 습식세정탑 시스템에 본 세 정수 처리시스템을 도입하면 세정수로서 재사용이 가능하다고 판단된다.
        45.
        2015.09 KCI 등재 서비스 종료(열람 제한)
        Characteristics of exhaust gas of solid refuse fuel (SRF) burning in a commercial scale of 12ton/day incinerator havebeen investigated. Combustion air for SRF burning is mixed with recirculated high temperature exhaust gas to diluteoxygen concentration and preheat itself. It is called high temperature EGR (Exhaust Gas Recirculation) combustion. Itis known that low oxygen concentration of diluted air reduces flame temperature and NOx emission, but also makes flameunstable. Highly heated air by mixing with high temperature exhaust gas makes flame stable by enhancement ofcombustion reaction. Concentrations of nitric oxide (NOx), carbon monoxide (CO), oxygen (O2) and carbon dioxide (CO2)in flue gas have been measured at stack. High temperature EGR incineration of SRF dramatically reduces nitric oxideemission and residual oxygen. Average concentrations of NOx, and CO are 71.5ppm and 86.6ppm especially at referenceoxygen concentration of 12% without any post treatment of NOx when the average outlet temperature of combustionchamber is 942oC. And average concentrations of O2 and CO2 are 9.59% and 8.3% especially.
        46.
        2014.01 KCI 등재 서비스 종료(열람 제한)
        Analyzing results of exhaust gas of solid fuel burning are investigated with measuring position in a pilot scale MILD(Moderate and Intense Low oxygen Dilution) combustor using high temperature exhaust gas recirculation. Flue gas hasbeen measured at exit of combustion chamber and stack, especially. Oxygen concentration measured at stack is higherand carbon dioxide concentration is lower than that measured at exit of combustion chamber, because air flows into theflue gas from the post-treatment facilities, such as gas cooler and bag filter, due to negative pressure caused by inducedblower. Low carbon dioxide concentration can cause an error which estimates higher air ratio than actual air flow rateneeded for complete combustion. Average calculated concentration of measured nitric oxide and carbon monoxide forreference concentration of 6% oxygen have no notable difference with measuring position. But, time resolution of thedata measured at exit of combustion chamber is better than that measured at stack. It is confirmed that MILD combustionof solid fuel of pulverized coal using high temperature exhaust gas recirculation can reduce dramatically nitric oxideemission.
        47.
        2013.01 KCI 등재 서비스 종료(열람 제한)
        MILD (Moderate and Intense Low oxygen Dilution) combustion using high temperature exhaust gas recirculation is applied to solid fuels of dried sewage sludge and pulverized coal combustion to investigate the effect of reduction of NOx emission in a pilot scale combustor. High temperature exhaust gas recirculation is accomplished by entraining high temperature exhaust gas to air jets at just exit of the combustion chamber without a heat exchanger. High temperature exhaust gas recirculation makes the solid fuel flame stable and extremely uniform color and uniform temperature distribution. NOx concentration at the combustor exit was 62% and 40% less in the high temperature exhaust recirculation MILD combustion compared with the conventional combustion using air jet only for sewage sludge and pulverized coal respectively.
        48.
        2008.03 KCI 등재 서비스 종료(열람 제한)
        최근 지구 환경 문제의 심각성이 대두되면서, 전과정 평가(Life Cycle Assessment)에 대한 선박 적용 연구가 국제적으로 활발하게 진행되고 있다. 이에 반하여 국내연구 수준은 아직 기초 연구수준에 그치고 있다. 본 논문에서는 선박 LCA의 개요를 살펴보고, 전과정평가의 선박 적용에 대한 연구를 다루었다. 특히 선박의 전생애 과정중에서 선박 운항 인벤토리 부분을 다루었다. 대상 선박은 목포해양대학교의 실습선 2척을 모델로 삼았으며 과거 수년간의 실적 데이터를 분석하여 운항인벤토리 중 배출 가스의 정략적 데이터를 분석하였다. 이 분석을 통하여 선박 총톤수 1톤을 운항 유지하는데 배출되는 배기 가스량을 분석하였고, 이와 함께 실습생 1명을 1년 교육시키는데 현재 어느 정도의 배기가스가 발생하고 있는지 살펴보았다.
        49.
        2004.07 KCI 등재 서비스 종료(열람 제한)
        This paper demonstrates the numerical simulation of three dimensional flow pattern for vehicular exhaust dispersion in the street canyons. The wind flow around buildings in urban is computed by the SIMPLEST method. The convection-diffusion equation was used to compute the NOx concentration level near buildings. Details are given of important boundary conditions and turbulence quantities variations. The simple turbulence model was used for unisotropic viscous effect. A control-volume based finite-difference method with the upwind scheme is employed for discretization equation. The simple turbulence model applied in this study has been verified through comparison between predicted and measured data near buildings. By the predictive results, the updraft induced by the presence of high-rise buildings is important in the transport of street level pollutant out from the street canyons. Our suggestion for reducing ground level pollution is to have high-rise buildings constructed or to reduce the channelling effect of street canyons.