This study performed the seismic response analysis of an LNG storage tank supported by a disconnected piled raft foundation (DPRF) with a load transfer platform (LTP). For this purpose, a precise analytical model with simultaneous consideration of Fluid-Structure Interaction (FSI) and Soil-Structure Interaction (SSI) was used. The effect of the LTP characteristics (thickness, stiffness) of the DPRF system on the seismic response of the superstructure (inner and outer tanks) and piles was analyzed. The analytical results were compared with the response of the piled raft foundation (PRF) system. The following conclusions can be drawn from the numerical results: (1) The DPRF system has a smaller bending moment and axial force at the head of the pile than the PRF system, even if the thickness and stiffness of the LTP change; (2) The DPRF system has a slight stiffness of the LTP and the superstructure member force can increase with increasing thickness. This is because as the stiffness of the LTP decreases and the thickness increases, the natural frequency of the LTP becomes closer to the natural frequency of the superstructure, which may affect the response of the superstructure. Therefore, when applying the DPRF system, it is recommended that the sensitivity analysis of the seismic response to the thickness and stiffness of the LTP must be performed.
유연한 지반에 놓인 액체저장탱크의 지진 거동은 유체-구조물-지반 상호작용에 의해 복잡하게 나타나므로, 이 시스템의 지진응답 과 피해를 정확하게 예측하기 위해서는 이를 엄밀히 고려하여야 한다. 이 연구에서는 유체-구조물-지반 상호작용을 엄밀히 고려하여 유연한 지반에 놓인 직사각형 액체저장탱크의 지진응답 해석을 수행하고 그 응답 특성을 분석하고자 한다. 이를 위해 지진하중 작용 시 발생하는 유체의 동수압력 및 지반과 구조물 간의 상호작용력을 유한요소 기법을 사용하여 산정한다. 이때, 반무한 지반에서의 에너지 방사를 고려하기 위해 mid-point integrated finite element와 점성 감쇠기를 사용하여 지반 원역의 거동을 모사한다. 이와 같이 산정된 동수압력과 지반-구조물 상호작용력을 구조물의 유한요소에 작용시킨다. 자유장 해석을 통하여 입사 지진파에 의한 유효 지진력을 산정한다. 유연한 지반에 놓인 직사각형 액체저장탱크의 지진응답 해석을 통하여 지반-구조물 상호작용의 효과로 인해 시스템 응답의 변화가 다양하게 나타남을 확인할 수 있다. 그러므로, 유연한 지반에 놓인 직사각형 액체저장탱크의 내진설계를 수행하거나 내진성능을 검토할 때는 유체-구조물-지반 상호작용을 엄밀히 고려하여야 할 것이다.
A 2D axisymmetric numerical analysis was performed to study the characteristics of charge process inside solar thermal storage tank. The porosity and heat transfer coefficient of filler material as well as inlet velocity of heat transfer fluid are selected as simulation parameters. The porosity is varied as 0.2, 0.5, and 0.8 to account for the effect of filler granule geometry. Two levels of the heat transfer coefficient is adopted to assess the heat transfer between heat transfer fluid and filler material. The inlet velocity is varied as 0.00278, 0.0278, and 0.278m/s. As both of the porosity and the heat transfer coefficient increase, the discrepancy of the temperature distributions between the filler and heat transfer fluid decreases. As the inlet velocity increases, the penetration depth of the heat transfer fluid increases proportionally.
A 2D axisymmetric numerical analysis was performed to study the characteristics of charge process inside solar thermal storage tank. The interfacial area density and inertial resistance of filler material are selected as simulation parameters. The interfacial area density is varied as 800, 2000, and 4000 1/m. The inertial resistance is varied as 1, 3, and 5 1/m. When the interfacial area density increases from 800 to 4000 1/m, the discrepancy of the temperature distributions between the filler and heat transfer fluid decreases. As inertial resistance increases from 1 to 5, both of the temperature and fluid flow pattern changes considerably.